Support Siemens Scalance Switch (#361)

This commit is contained in:
Christoph Handel
2019-10-15 19:26:49 +02:00
committed by Oliver Gorwits
parent 78c194faee
commit 0791b7cccb
3 changed files with 454 additions and 1 deletions

View File

@@ -1002,6 +1002,12 @@ Subclass for redlion routers.
See documentation in L<SNMP::Info::Layer3::Redlion> for details. See documentation in L<SNMP::Info::Layer3::Redlion> for details.
=item SNMP::Info::Layer3::Scalance
Subclass for Siemens Scalance devices.
See documentation in L<SNMP::Info::Layer3::Scalance> for details.
=item SNMP::Info::Layer3::SonicWALL =item SNMP::Info::Layer3::SonicWALL
Subclass for generic SonicWALL devices. Subclass for generic SonicWALL devices.
@@ -1903,6 +1909,14 @@ sub device_type {
$objtype = 'SNMP::Info::Layer2::NWSS2300' $objtype = 'SNMP::Info::Layer2::NWSS2300'
if ( if (
$desc =~ /^(Nortel\s)??Wireless\sSecurity\sSwitch\s23[568][012]\b/); $desc =~ /^(Nortel\s)??Wireless\sSecurity\sSwitch\s23[568][012]\b/);
# Siemens Simatic Scalance
# Scalance overwrites layers later,
# so if we don't add it here (layer3) and at other
# it would flip/flop between those
$objtype = 'SNMP::Info::Layer3::Scalance'
if ( $soid =~ /\.1\.3\.6\.1\.4\.1\.4329\.6\.1\.2/i );
# Generic device classification based upon sysObjectID # Generic device classification based upon sysObjectID
if ( ( $objtype eq 'SNMP::Info::Layer3' ) if ( ( $objtype eq 'SNMP::Info::Layer3' )
@@ -1911,7 +1925,6 @@ sub device_type {
{ {
$objtype = $l3sysoidmap{$id}; $objtype = $l3sysoidmap{$id};
} }
# Layer 2 Supported # Layer 2 Supported
} }
elsif ( $info->has_layer(2) ) { elsif ( $info->has_layer(2) ) {
@@ -2103,6 +2116,13 @@ sub device_type {
$objtype = 'SNMP::Info::Layer7::CiscoIPS' $objtype = 'SNMP::Info::Layer7::CiscoIPS'
if ( $soid =~ /\.1\.3\.6\.1\.4\.1\.9\.1\.1545/i ); if ( $soid =~ /\.1\.3\.6\.1\.4\.1\.9\.1\.1545/i );
# Siemens Simatic Scalance
# Scalance overwrites layers later,
# so if we don't add it here (layer3) and at other
# it would flip/flop between those
$objtype = 'SNMP::Info::Layer3::Scalance'
if ( $soid =~ /\.1\.3\.6\.1\.4\.1\.4329\.6\.1\.2/i );
# Generic device classification based upon sysObjectID # Generic device classification based upon sysObjectID
if ( defined($id) and $objtype eq 'SNMP::Info') { if ( defined($id) and $objtype eq 'SNMP::Info') {
if ( defined $l3sysoidmap{$id} ) { if ( defined $l3sysoidmap{$id} ) {

View File

@@ -0,0 +1,332 @@
# SNMP::Info::Layer3::Scalance - SNMP Interface to Siemens Scalance
#
# Copyright (c) 2019 Christoph Handel GSI Helmholtzzentrum fuer
# Schwerionenforschung
#
# Copyright (c) 2008-2009 Max Baker changes from version 0.8 and beyond.
#
# Copyright (c) 2002,2003 Regents of the University of California
#
# All rights reserved.
#
# Redistribution and use in source and binary forms, with or without
# modification, are permitted provided that the following conditions are met:
#
# * Redistributions of source code must retain the above copyright notice,
# this list of conditions and the following disclaimer.
# * Redistributions in binary form must reproduce the above copyright
# notice, this list of conditions and the following disclaimer in the
# documentation and/or other materials provided with the distribution.
# * Neither the name of the University of California, Santa Cruz ,
# the GSI Helmholtzzentrum fuer Schwerionenforschung, nor the
# names of its contributors may be used to endorse or promote products
# derived from this software without specific prior written permission
#
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
# AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
# IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE
# LIABLE FOR # ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
# CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
# SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
# INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
# CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
# ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
# POSSIBILITY OF SUCH DAMAGE.
#
package SNMP::Info::Layer3::Scalance;
use strict;
use warnings;
use Exporter;
use SNMP::Info::Layer3;
use SNMP::Info::MAU;
use SNMP::Info::LLDP;
use SNMP::Info::Bridge;
use Socket;
use Data::Dumper;
@SNMP::Info::Layer3::Scalance::ISA = qw/
SNMP::Info::Layer3
SNMP::Info::MAU
SNMP::Info::Bridge
SNMP::Info::LLDP
Exporter
/;
@SNMP::Info::Layer3::Scalance::EXPORT_OK = qw//;
our ($VERSION, %GLOBALS, %MIBS, %FUNCS, %PORTSTAT, %MODEL_MAP, %MUNGE);
$VERSION = '3.68';
%MIBS = (
%SNMP::Info::Layer3::MIBS,
%SNMP::Info::MAU::MIBS,
%SNMP::Info::LLDP::MIBS,
%SNMP::Info::Bridge::MIBS,
'SN-MSPS-SCX-MIB' => 'snMsps',
'AUTOMATION-SYSTEM-MIB' => 'automationManufacturerId',
);
%GLOBALS = (
%SNMP::Info::Layer3::GLOBALS,
%SNMP::Info::MAU::GLOBALS,
%SNMP::Info::LLDP::GLOBALS,
%SNMP::Info::Bridge::GLOBALS,
'serial1' => 'automationSerialNumber.0',
'ps1_status' => 'snMspsPowerSupply1State.0',
'ps2_status' => 'snMspsPowerSupply2State.0',
'os_ver' => 'automationSwRevision.0',
);
%FUNCS = (
%SNMP::Info::Layer3::FUNCS,
%SNMP::Info::MAU::FUNCS,
%SNMP::Info::LLDP::FUNCS,
%SNMP::Info::Bridge::FUNCS,
);
%MUNGE = (
# Inherit all the built in munging
%SNMP::Info::Layer3::MUNGE,
%SNMP::Info::MAU::MUNGE,
%SNMP::Info::LLDP::MUNGE,
%SNMP::Info::Bridge::MUNGE,
);
sub layers {
# at least x500 reports value 72, which is layer 4+7
# but it sure is a bridge and can do 2 and 3
return '00000111';
}
sub os {
return 'scalance';
}
sub vendor {
return 'siemens';
}
sub model {
my $scalance = shift;
# object id is only the general class (x500, x400, etc)
# extract something meaningful from the description
# my $id = $scalance->id();
my $description = $scalance->description();
# Siemens, SIMATIC NET, SCALANCE XR524-8C 2PS, 6GK5 524-8GS00-4AR2, HW: Version 1,...
$description =~ s/.*?(SCALANCE .*?),.*/$1/;
return $description;
}
sub mac {
# use dot1dBaseBridgeAddress
my $scalance = shift;
return $scalance->b_mac();
}
sub os_ver {
# clean up os_ver string
my $scalance = shift;
my $result = $scalance->SUPER::os_ver();
$result =~ s/^V//;
return $result;
}
sub i_description {
# munge interface descriptions, from
#
# Siemens, SIMATIC NET, SCALANCE XR524-8C 2PS, 6GK5 524-8GS00-4AR2,
# HW: Version 1, FW: Version V06.02.02, SERIAL, Ethernet Port, R0/S0/X1 P16
#
# to
#
# R0/S0/X1 P16
my $scalance = shift;
my $orig = $scalance->SUPER::i_description();
my %result;
foreach my $iid ( keys %$orig ) {
my $descr = $orig->{$iid};
my $short;
($short) = $descr =~ /.*(?:Port, |VLAN, )(.*)$/;
if ( ! $short ) {
# splitting at VLAN/PORT failed, just the part after the last comma
($short) = $descr =~ /.*, (.*)$/;
}
$result{$iid} = $short;
}
return \%result;
}
sub lldp_ip {
my $scalance = shift;
my %result;
my $remotes = $scalance->lldp_rem_sysname();
foreach my $port ( keys %$remotes) {
my $ip = gethostbyname($remotes->{$port});
if ($ip) {
$result{$port} = inet_ntoa($ip);
}
}
return \%result
};
1;
__END__
=head1 NAME
SNMP::Info::Layer3::Scalance - SNMP Interface to Siemens Scalance Switches
=head1 AUTHOR
Christoph Handel
=head1 SYNOPSIS
# Let SNMP::Info determine the correct subclass for you.
my $scalance = new SNMP::Info(
AutoSpecify => 1,
Debug => 1,
DestHost => 'myswitch',
Community => 'public',
Version => 2
)
or die "Can't connect to DestHost.\n";
my $class = $scalance->class();
print "SNMP::Info determined this device to fall under subclass : $class\n";
=head1 DESCRIPTION
Provides abstraction to the configuration information obtainable from a
Siemens Scalance Switch via SNMP.
Tested only with sclance xr524
=head2 Inherited Classes
=over
=item SNMP::Info::Layer3
=item SNMP::Info::MAU
=item SNMP::Info::LLDP
=item SNMP::Info::Bridge
=back
=head2 Required MIBs
=over
=item F<SN-MSPS-SCX-MIB>
=item F<AUTOMATION-SYSTEM-MIB>
=item F<AUTOMATION-SMI.txt>
=item F<AUTOMATION-SYSTEM-MIB>
=item F<AUTOMATION-TC>
=item F<SIEMENS-SMI>
=back
L<https://support.industry.siemens.com/cs/document/22015045/private-mibs%3A-scalance-x-scalance-w-and-snmp-opc-profile?dti=0&lc=en-DE>
L<https://support.industry.siemens.com/cs/document/67637278/automationmib-now-available-for-download-in-version-v02-00-00-02-?dti=0&lc=en-TN>
=head1 Change Log
=head1 GLOBALS
These are methods that return scalar value from SNMP
=over
=item $scalance->layers()
Overwrite snmp value, we support 1-3
=item $scalance->os()
Returns scalance
=item $scalance->vendor()
Returns siemens
=item $scalance->model()
extrace a meaningful name from description
=item $scalance->mac()
use the dot1dBaseBridgeAddress
=item $scalance->os_ver()
clean up os_version string
=item $scalance->i_description()
siemens returns a description including firmware, switch serial, etc
clean it up. Try to use anything past VLAN or Port. And if this fails
past the last comma
=item $scalance->lldp_ip()
simatic does not implement lldpRemManAddrIfSubtype
but remote system names are available
try to resolve them via DNS and use that
=back
=head2 Globals imported from SNMP::Info::Layer3
See documentation in L<SNMP::Info::Layer3/"GLOBALS"> for details.
=head2 Globals imported from SNMP::Info::MAU
See documentation in L<SNMP::Info::MAU/"GLOBALS"> for details.
=head1 TABLE METHODS
These are methods that return tables of information in the form of a reference
to a hash.
=head2 Overrides
=over 4
=item $scalance->lldp_ip()
Returns reference to hash of ports to remote ips.
simatic does not implement lldpRemManAddrIfSubtype
but remote system names are available
try to resolve them via DNS and use that.
=back
=head2 Table Methods imported from SNMP::Info::Layer3
See documentation in L<SNMP::Info::Layer3/"TABLE METHODS"> for details.
=head2 Table Methods imported from SNMP::Info::MAU
See documentation in L<SNMP::Info::MAU/"TABLE METHODS"> for details.
=cut
# vim: filetype=perl ts=4 sw=4 sta et sts=4 ai

View File

@@ -0,0 +1,101 @@
# Test::SNMP::Info::Layer3::Scalance
#
# Copyright (c) 2019 Christoph Handel GSI Helmholtzzentrum fuer
# Schwerionenforschung
# Copyright (c) 2018 Eric Miller
# All rights reserved.
#
# Redistribution and use in source and binary forms, with or without
# modification, are permitted provided that the following conditions are met:
#
# * Redistributions of source code must retain the above copyright notice,
# this list of conditions and the following disclaimer.
# * Redistributions in binary form must reproduce the above copyright
# notice, this list of conditions and the following disclaimer in the
# documentation and/or other materials provided with the distribution.
# * Neither the name of the University of California, Santa Cruz,
# the GSI Helmholtzzentrum fuer Schwerionenforschung nor the
# names of its contributors may be used to endorse or promote products
# derived from this software without specific prior written permission.
#
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
# AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
# IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE
# LIABLE FOR # ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
# CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
# SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
# INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
# CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
# ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
# POSSIBILITY OF SUCH DAMAGE.
package Test::SNMP::Info::Layer3::Scalance;
use Test::Class::Most parent => 'My::Test::Class';
use SNMP::Info::Layer3::Scalance;
# Remove this startup override once we have full method coverage
sub startup : Tests(startup => 1) {
my $test = shift;
$test->SUPER::startup();
$test->todo_methods(1);
}
sub setup : Tests(setup) {
my $test = shift;
$test->SUPER::setup;
# Start with a common cache that will serve most tests
my $version = "V06.02.02";
my $model = 'Siemens, SIMATIC NET, SCALANCE XR524-8C 2PS, 6GK5 524-8GS00-4AR2, HW: Version 1';
my $serial = 'SVPL1234567';
my $iprefix = "$model FW: Version version, $serial";
my $cache_data = {
'_layers' => 74,
'_description' => "$model, FW: Version $version, $serial",
'_id' => '.1.3.6.1.4.1.4329.6.1.2',
# i have no idea why i need to add i_description here
# guess something with calling SUPER
'_i_description' => {},
'store' => {
'i_description' => {
1 => "$iprefix, Ethernet Port, R0/S0/X1 P1",
2 => "$iprefix, L3 VLAN, VLAN1",
3 => "$iprefix, loopback",
},
},
};
$test->{info}->cache($cache_data);
}
sub layers : Tests(2) {
my $test = shift;
can_ok($test->{info}, 'layers');
is($test->{info}->layers(), '00000111', q(Layers returns '00000111'));
}
sub model : Tests(2) {
my $test = shift;
is($test->{info}->model(), 'SCALANCE XR524-8C 2PS', q(Model extracted));
}
sub i_description : Tests(3) {
my $test = shift;
can_ok($test->{info}, 'interfaces');
my $expected = {1 => 'R0/S0/X1 P1', 2 => 'VLAN1', 3 => 'loopback'};
cmp_deeply($test->{info}->i_description(),
$expected, q(i_description have expected values));
}
1;
# vim: filetype=perl ts=4 sw=4 sta et sts=4 ai