POD updates - spell check
This commit is contained in:
24
Info.pm
24
Info.pm
@@ -350,7 +350,7 @@ See documentation in L<SNMP::Info::FDP> for details.
|
|||||||
=item SNMP::Info::IPv6
|
=item SNMP::Info::IPv6
|
||||||
|
|
||||||
SNMP Interface for obtaining configured IPv6 addresses and mapping IPv6
|
SNMP Interface for obtaining configured IPv6 addresses and mapping IPv6
|
||||||
addresses to MACs and interfaces, using information from F<IP-MIB>,
|
addresses to MAC addresses and interfaces, using information from F<IP-MIB>,
|
||||||
F<IPV6-MIB> and/or F<CISCO-IETF-IP-MIB>.
|
F<IPV6-MIB> and/or F<CISCO-IETF-IP-MIB>.
|
||||||
|
|
||||||
See documentation in L<SNMP::Info::IPv6> for details.
|
See documentation in L<SNMP::Info::IPv6> for details.
|
||||||
@@ -727,6 +727,12 @@ Subclass for Brocade (Foundry) Network devices.
|
|||||||
|
|
||||||
See documentation in L<SNMP::Info::Layer3::Foundry> for details.
|
See documentation in L<SNMP::Info::Layer3::Foundry> for details.
|
||||||
|
|
||||||
|
=item SNMP::Info::Layer3::H3C
|
||||||
|
|
||||||
|
SNMP Interface to Layer 3 Devices, H3C & HP A-series.
|
||||||
|
|
||||||
|
See documentation in L<SNMP::Info::Layer3::H3C> for details.
|
||||||
|
|
||||||
=item SNMP::Info::Layer3::HP9300
|
=item SNMP::Info::Layer3::HP9300
|
||||||
|
|
||||||
Subclass for HP network devices which Foundry Networks was the
|
Subclass for HP network devices which Foundry Networks was the
|
||||||
@@ -880,7 +886,7 @@ Creates a new object and connects via SNMP::Session.
|
|||||||
'BigInt' => 1,
|
'BigInt' => 1,
|
||||||
'BulkWalk' => 1,
|
'BulkWalk' => 1,
|
||||||
'BulkRepeaters' => 20,
|
'BulkRepeaters' => 20,
|
||||||
'IgnoreNetSNMPConf => 1,
|
'IgnoreNetSNMPConf' => 1,
|
||||||
'LoopDetect' => 1,
|
'LoopDetect' => 1,
|
||||||
'DestHost' => 'myrouter',
|
'DestHost' => 'myrouter',
|
||||||
'Community' => 'public',
|
'Community' => 'public',
|
||||||
@@ -938,9 +944,9 @@ snmp.local.conf, from /etc/snmp, /usr/share/snmp, /usr/lib(64)/snmp, or
|
|||||||
$HOME/.snmp and uses those settings to automatically parse MIB files, etc.
|
$HOME/.snmp and uses those settings to automatically parse MIB files, etc.
|
||||||
|
|
||||||
Set to C<1> "on" to ignore Net-SNMP configuration files by overriding the
|
Set to C<1> "on" to ignore Net-SNMP configuration files by overriding the
|
||||||
C<SNMPCONFPATH> environmental varible during object initialization. Note:
|
C<SNMPCONFPATH> environmental variable during object initialization. Note:
|
||||||
MibDirs must be defined or Net-SNMP will not be able to load MIB's and
|
MibDirs must be defined or Net-SNMP will not be able to load MIBs and
|
||||||
initalize the object.
|
initialize the object.
|
||||||
|
|
||||||
(default 0, which means "off")
|
(default 0, which means "off")
|
||||||
|
|
||||||
@@ -2343,7 +2349,7 @@ For protocol specific information and implementation:
|
|||||||
|
|
||||||
=back
|
=back
|
||||||
|
|
||||||
=head3 Topology Capabilties
|
=head3 Topology Capabilities
|
||||||
|
|
||||||
=over
|
=over
|
||||||
|
|
||||||
@@ -3275,7 +3281,7 @@ sub init {
|
|||||||
# Get MibDirs if provided
|
# Get MibDirs if provided
|
||||||
my $mibdirs = $self->{mibdirs} || [];
|
my $mibdirs = $self->{mibdirs} || [];
|
||||||
|
|
||||||
# SNMP::initMib and SNMP::addMibDirs both look for some inital MIBs
|
# SNMP::initMib and SNMP::addMibDirs both look for some initial MIBs
|
||||||
# so if we are not using Net-SNMP configuration files we need to
|
# so if we are not using Net-SNMP configuration files we need to
|
||||||
# specify where the MIBs are before those calls.
|
# specify where the MIBs are before those calls.
|
||||||
|
|
||||||
@@ -4207,13 +4213,13 @@ sub _validate_autoload_method {
|
|||||||
|
|
||||||
=item $info->can()
|
=item $info->can()
|
||||||
|
|
||||||
Overrides UNIVERSAL::can() so that objects will correctly report thier
|
Overrides UNIVERSAL::can() so that objects will correctly report their
|
||||||
capabilities to include dynamic methods generated at run time via AUTOLOAD.
|
capabilities to include dynamic methods generated at run time via AUTOLOAD.
|
||||||
|
|
||||||
Calls parent can() first to see if method exists, if not validates that a
|
Calls parent can() first to see if method exists, if not validates that a
|
||||||
method should be created then dispatches to the appropriate internal method
|
method should be created then dispatches to the appropriate internal method
|
||||||
for creation. The newly created method is inserted into the symbol table
|
for creation. The newly created method is inserted into the symbol table
|
||||||
returning to AUTOLOAD only for the inital method call.
|
returning to AUTOLOAD only for the initial method call.
|
||||||
|
|
||||||
Returns undef if the method does not exist and can not be created.
|
Returns undef if the method does not exist and can not be created.
|
||||||
|
|
||||||
|
|||||||
@@ -65,7 +65,7 @@ __END__
|
|||||||
|
|
||||||
=head1 NAME
|
=head1 NAME
|
||||||
|
|
||||||
SNMP::Info::AdslLine - SNMP Interface to the ADSL-LINE-MIB
|
SNMP::Info::AdslLine - SNMP Interface to the F<ADSL-LINE-MIB>
|
||||||
|
|
||||||
=head1 AUTHOR
|
=head1 AUTHOR
|
||||||
|
|
||||||
@@ -120,7 +120,7 @@ MIBs can be found at ftp://ftp.cisco.com/pub/mibs/v2/v2.tar.gz
|
|||||||
=head2 ATUC channel table (C<adslAtucChanTable>)
|
=head2 ATUC channel table (C<adslAtucChanTable>)
|
||||||
|
|
||||||
This table provides one row for each ATUC channel.
|
This table provides one row for each ATUC channel.
|
||||||
ADSL channel interfaces are those ifEntries where ifType
|
ADSL channel interfaces are those C<ifEntries> where C<ifType>
|
||||||
is equal to adslInterleave(124) or adslFast(125).
|
is equal to adslInterleave(124) or adslFast(125).
|
||||||
|
|
||||||
=over
|
=over
|
||||||
@@ -146,7 +146,7 @@ is equal to adslInterleave(124) or adslFast(125).
|
|||||||
=head2 ATUR channel table (C<adslAturChanTable>)
|
=head2 ATUR channel table (C<adslAturChanTable>)
|
||||||
|
|
||||||
This table provides one row for each ATUR channel.
|
This table provides one row for each ATUR channel.
|
||||||
ADSL channel interfaces are those ifEntries where ifType
|
ADSL channel interfaces are those C<ifEntries> where C<ifType>
|
||||||
is equal to adslInterleave(124) or adslFast(125).
|
is equal to adslInterleave(124) or adslFast(125).
|
||||||
|
|
||||||
=over
|
=over
|
||||||
|
|||||||
@@ -175,7 +175,7 @@ Maps the C<pethPsePortTable> to C<ifIndex> by way of the F<ENTITY-MIB>.
|
|||||||
=item $poe->peth_port_power()
|
=item $poe->peth_port_power()
|
||||||
|
|
||||||
Power supplied by PoE ports, in milliwatts
|
Power supplied by PoE ports, in milliwatts
|
||||||
("cpeExtPsePortPwrConsumption")
|
(C<cpeExtPsePortPwrConsumption>)
|
||||||
|
|
||||||
=back
|
=back
|
||||||
|
|
||||||
@@ -185,8 +185,8 @@ Power supplied by PoE ports, in milliwatts
|
|||||||
|
|
||||||
=item $poe->peth_port_neg_power()
|
=item $poe->peth_port_neg_power()
|
||||||
|
|
||||||
Power negotiated using CDP, in milliwats
|
Power negotiated using CDP, in milliwatts
|
||||||
("cdpCachePowerConsumption")
|
(C<cdpCachePowerConsumption>)
|
||||||
|
|
||||||
=back
|
=back
|
||||||
|
|
||||||
|
|||||||
@@ -402,62 +402,25 @@ Returns mem_free() + mem_used()
|
|||||||
|
|
||||||
=item $ciscostats->os()
|
=item $ciscostats->os()
|
||||||
|
|
||||||
Tries to parse if device is running IOS, CatOS, IOS-XE or something else from description()
|
Tries to parse if device is running 'IOS', 'CatOS', 'IOS-XE' or something else
|
||||||
|
from description()
|
||||||
|
|
||||||
Available values:
|
Available values:
|
||||||
|
|
||||||
=over
|
'ios' for Cisco IOS
|
||||||
|
'ios-xe' for Cisco IOS XE
|
||||||
=item ios
|
'pix' for Cisco PIX
|
||||||
|
'asa' for Cisco ASA
|
||||||
Cisco IOS
|
'fwsm' for Single-mode FWSM
|
||||||
|
'fwsm-admin' for Admin context of multi-context FWSM
|
||||||
=item ios-xe
|
'fwsm-context' for Standard context of multi-context FWSM
|
||||||
|
'ace-admin' for Admin context of ACE module
|
||||||
Cisco IOS XE
|
'ace-context' for Standard context of ACE module (NB: No OS version
|
||||||
|
detection is available, but will be the same as it's
|
||||||
=item pix
|
'ace admin')
|
||||||
|
'css' for Cisco Content Switch
|
||||||
Cisco PIX
|
'css-sca' for Cisco Content Switch Secure Content Acceleration
|
||||||
|
'san-os' for Cisco SAN-OS
|
||||||
=item asa
|
|
||||||
|
|
||||||
Cisco ASA
|
|
||||||
|
|
||||||
=item fwsm
|
|
||||||
|
|
||||||
Single-mode FWSM
|
|
||||||
|
|
||||||
=item fwsm-admin
|
|
||||||
|
|
||||||
Admin context of multi-context FWSM
|
|
||||||
|
|
||||||
=item fwsm-context
|
|
||||||
|
|
||||||
Standard context of multi-context FWSM
|
|
||||||
|
|
||||||
=item ace-admin
|
|
||||||
|
|
||||||
Admin context of ACE module
|
|
||||||
|
|
||||||
=item ace-context
|
|
||||||
|
|
||||||
Standard context of ACE module (NB: No OS version detection
|
|
||||||
is available, but will be the same as it's 'ace admin')
|
|
||||||
|
|
||||||
=item css
|
|
||||||
|
|
||||||
Cisco Content Switch
|
|
||||||
|
|
||||||
=item css-sca
|
|
||||||
|
|
||||||
Cisco Content Switch Secure Content Acceleration
|
|
||||||
|
|
||||||
=item san-os
|
|
||||||
|
|
||||||
Cisco SAN-OS
|
|
||||||
|
|
||||||
=back
|
|
||||||
|
|
||||||
=item $ciscostats->os_ver()
|
=item $ciscostats->os_ver()
|
||||||
|
|
||||||
@@ -466,7 +429,7 @@ to parsing C<CISCO-IMAGE-MIB::ciscoImageString> if needed
|
|||||||
|
|
||||||
=item $ciscostats->os_bin()
|
=item $ciscostats->os_bin()
|
||||||
|
|
||||||
Tries to parse ROMMON version from rom_id() string
|
Tries to parse C<ROMMON> version from rom_id() string
|
||||||
|
|
||||||
=item $ciscostats->ios_cpu()
|
=item $ciscostats->ios_cpu()
|
||||||
|
|
||||||
|
|||||||
@@ -394,8 +394,9 @@ Jeroen van Ingen and Carlos Vicente
|
|||||||
=head1 DESCRIPTION
|
=head1 DESCRIPTION
|
||||||
|
|
||||||
The SNMP::Info::IPv6 class implements functions to for mapping IPv6 addresses
|
The SNMP::Info::IPv6 class implements functions to for mapping IPv6 addresses
|
||||||
to MAC addresses, interfaces and more. It will use data from the IP-MIB, IPV6-MIB
|
to MAC addresses, interfaces and more. It will use data from the F<IP-MIB>,
|
||||||
or the CISCO-IETF-IP-MIB, whichever is supported by the device.
|
F<IPV6-MIB>, or the F<CISCO-IETF-IP-MIB>, whichever is supported by the
|
||||||
|
device.
|
||||||
|
|
||||||
This class is inherited by Info::Layer3 to provide IPv6 node tracking across
|
This class is inherited by Info::Layer3 to provide IPv6 node tracking across
|
||||||
device classes.
|
device classes.
|
||||||
|
|||||||
@@ -776,12 +776,12 @@ Power supply 2 status
|
|||||||
=item $hp->peth_port_power()
|
=item $hp->peth_port_power()
|
||||||
|
|
||||||
Power supplied by PoE ports, in milliwatts
|
Power supplied by PoE ports, in milliwatts
|
||||||
("hpicfPoePethPsePortPower")
|
(C<hpicfPoePethPsePortPower>)
|
||||||
|
|
||||||
=item $hp->stp_ver()
|
=item $hp->stp_ver()
|
||||||
|
|
||||||
Returns what version of STP the device is running.
|
Returns what version of STP the device is running.
|
||||||
("hpicfBridgeRstpForceVersion" with fallback to inherited stp_ver())
|
(C<hpicfBridgeRstpForceVersion> with fallback to inherited stp_ver())
|
||||||
|
|
||||||
=back
|
=back
|
||||||
|
|
||||||
@@ -820,7 +820,8 @@ Returns reference to hash of IIDs to admin duplex setting.
|
|||||||
|
|
||||||
=item $hp->vendor_i_type()
|
=item $hp->vendor_i_type()
|
||||||
|
|
||||||
Returns reference to hash of IIDs to HP specific port type (hpSwitchPortType).
|
Returns reference to hash of IIDs to HP specific port type
|
||||||
|
(C<hpSwitchPortType>).
|
||||||
|
|
||||||
=item $hp->i_name()
|
=item $hp->i_name()
|
||||||
|
|
||||||
|
|||||||
@@ -652,7 +652,8 @@ Returns reference to hash of IIDs to admin duplex setting.
|
|||||||
|
|
||||||
=item $hp->vendor_i_type()
|
=item $hp->vendor_i_type()
|
||||||
|
|
||||||
Returns reference to hash of IIDs to HP specific port type (hpSwitchPortType).
|
Returns reference to hash of IIDs to HP specific port type
|
||||||
|
(C<hpSwitchPortType>).
|
||||||
|
|
||||||
=item $hp->i_name()
|
=item $hp->i_name()
|
||||||
|
|
||||||
|
|||||||
@@ -150,7 +150,7 @@ These are methods that return scalar value from SNMP
|
|||||||
|
|
||||||
=item $hp->os()
|
=item $hp->os()
|
||||||
|
|
||||||
Returns hpvc
|
Returns C<'hpvc'>
|
||||||
|
|
||||||
=item $hp->os_bin()
|
=item $hp->os_bin()
|
||||||
|
|
||||||
|
|||||||
@@ -863,7 +863,7 @@ Returns 'trapeze'
|
|||||||
|
|
||||||
Tries to reference $nwss2300->id() to F<NTWS-REGISTRATION-DEVICES-MIB>
|
Tries to reference $nwss2300->id() to F<NTWS-REGISTRATION-DEVICES-MIB>
|
||||||
|
|
||||||
Removes 'ntwsSwitch' for readability.
|
Removes C<'ntwsSwitch'> for readability.
|
||||||
|
|
||||||
=item $nwss2300->serial()
|
=item $nwss2300->serial()
|
||||||
|
|
||||||
@@ -1170,7 +1170,7 @@ for Ethernet interfaces, nwss2300_ap_name() for thin AP interfaces.
|
|||||||
=item $nwss2300->i_type()
|
=item $nwss2300->i_type()
|
||||||
|
|
||||||
Returns reference to map of IIDs to interface descriptions. Returns
|
Returns reference to map of IIDs to interface descriptions. Returns
|
||||||
C<ifType> for Ethernet interfaces and 'capwapWtpVirtualRadio' for thin AP
|
C<ifType> for Ethernet interfaces and C<'capwapWtpVirtualRadio'> for thin AP
|
||||||
interfaces.
|
interfaces.
|
||||||
|
|
||||||
=item $nwss2300->i_up()
|
=item $nwss2300->i_up()
|
||||||
|
|||||||
@@ -141,7 +141,7 @@ Returns C<'sgos'>
|
|||||||
|
|
||||||
=item $router->os_ver()
|
=item $router->os_ver()
|
||||||
|
|
||||||
Tries to resolve version string from "sgProxyVersion"
|
Tries to resolve version string from C<"sgProxyVersion">.
|
||||||
|
|
||||||
=back
|
=back
|
||||||
|
|
||||||
|
|||||||
@@ -202,17 +202,17 @@ to a hash.
|
|||||||
=item $fwsm->at_paddr()
|
=item $fwsm->at_paddr()
|
||||||
|
|
||||||
This function derives the at_paddr information from the n2p_paddr() table as
|
This function derives the at_paddr information from the n2p_paddr() table as
|
||||||
the MIB to provide that information isn't supported on FWSMs.
|
the MIB to provide that information isn't supported on FWSM.
|
||||||
|
|
||||||
=item $fwsm->at_netaddr()
|
=item $fwsm->at_netaddr()
|
||||||
|
|
||||||
This function derives the at_netaddr information from the n2p_paddr() table as
|
This function derives the at_netaddr information from the n2p_paddr() table as
|
||||||
the MIB to provide that information isn't supported on FWSMs.
|
the MIB to provide that information isn't supported on FWSM.
|
||||||
|
|
||||||
=item $fwsm->at_ifaddr()
|
=item $fwsm->at_ifaddr()
|
||||||
|
|
||||||
This function derives the at_ifaddr information from the n2p_paddr() table as
|
This function derives the at_ifaddr information from the n2p_paddr() table as
|
||||||
the MIB to provide that information isn't supported on FWSMs.
|
the MIB to provide that information isn't supported on FWSM.
|
||||||
|
|
||||||
=back
|
=back
|
||||||
|
|
||||||
|
|||||||
@@ -390,8 +390,8 @@ identifier (iid).
|
|||||||
|
|
||||||
The LLDP table time filter implementation continuously increments when
|
The LLDP table time filter implementation continuously increments when
|
||||||
walked and we may never reach the end of the table. This behavior can be
|
walked and we may never reach the end of the table. This behavior can be
|
||||||
modified with the "set snmp timefilter break disable" command,
|
modified with the C<"set snmp timefilter break disable"> command,
|
||||||
unfortunately it is not the default. These methods are overriden to
|
unfortunately it is not the default. These methods are overridden to
|
||||||
supply a partial value of zero which means no time filter.
|
supply a partial value of zero which means no time filter.
|
||||||
|
|
||||||
=over
|
=over
|
||||||
|
|||||||
@@ -957,7 +957,7 @@ Power supplied by PoE ports, in milliwatts
|
|||||||
|
|
||||||
=item $extreme->peth_power_watts()
|
=item $extreme->peth_power_watts()
|
||||||
|
|
||||||
The configured maximum amount of inline power available to the slot.
|
The configured maximum amount of in-line power available to the slot.
|
||||||
|
|
||||||
(C<extremePethSlotPowerLimit>)
|
(C<extremePethSlotPowerLimit>)
|
||||||
|
|
||||||
|
|||||||
@@ -405,7 +405,7 @@ Returns the human set port name if exists.
|
|||||||
|
|
||||||
=item $f5->i_type()
|
=item $f5->i_type()
|
||||||
|
|
||||||
Returns 'ethernetCsmacd' for each C<ifIndex>.
|
Returns C<'ethernetCsmacd'> for each C<ifIndex>.
|
||||||
|
|
||||||
=back
|
=back
|
||||||
|
|
||||||
|
|||||||
@@ -294,7 +294,7 @@ These are methods that return scalar values from SNMP:
|
|||||||
|
|
||||||
=item $force10->vendor()
|
=item $force10->vendor()
|
||||||
|
|
||||||
Returns 'force10'
|
Returns C<'force10'>
|
||||||
|
|
||||||
=item $force10->hasCDP()
|
=item $force10->hasCDP()
|
||||||
|
|
||||||
@@ -306,7 +306,7 @@ Tries to reference $force10->id() to the Force10 product MIB listed above.
|
|||||||
|
|
||||||
=item $force10->os()
|
=item $force10->os()
|
||||||
|
|
||||||
Returns 'ftos'
|
Returns C<'ftos'>.
|
||||||
|
|
||||||
=item $force10->os_ver()
|
=item $force10->os_ver()
|
||||||
|
|
||||||
|
|||||||
@@ -575,7 +575,7 @@ Subclass for Juniper Devices running JUNOS
|
|||||||
|
|
||||||
=over
|
=over
|
||||||
|
|
||||||
=item F<JUNIPER-VLAN-MIB> dated "200901090000Z" -- Fri Jan 09 00:00:00 2009 UTC or later.
|
=item F<JUNIPER-VLAN-MIB> dated "200901090000Z" or later.
|
||||||
|
|
||||||
=item F<JUNIPER-CHASSIS-DEFINES-MIB>
|
=item F<JUNIPER-CHASSIS-DEFINES-MIB>
|
||||||
|
|
||||||
|
|||||||
@@ -134,11 +134,11 @@ These are methods that return scalar value from SNMP
|
|||||||
|
|
||||||
=item $mikrotik->vendor()
|
=item $mikrotik->vendor()
|
||||||
|
|
||||||
Returns 'mikrotik'.
|
Returns C<'mikrotik'>.
|
||||||
|
|
||||||
=item $mikrotik->os()
|
=item $mikrotik->os()
|
||||||
|
|
||||||
Returns 'routeros'.
|
Returns C<'routeros'>.
|
||||||
|
|
||||||
=item $mikrotik->model()
|
=item $mikrotik->model()
|
||||||
|
|
||||||
|
|||||||
@@ -544,11 +544,11 @@ Tries to reference $netscreen->id() to F<NETSCREEN-PRODUCTS-MIB>
|
|||||||
|
|
||||||
=item $netscreen->vendor()
|
=item $netscreen->vendor()
|
||||||
|
|
||||||
Returns 'juniper'
|
Returns C<'juniper'>
|
||||||
|
|
||||||
=item $netscreen->os()
|
=item $netscreen->os()
|
||||||
|
|
||||||
Returns 'screenos'
|
Returns C<'screenos'>
|
||||||
|
|
||||||
=item $netscreen->os_ver()
|
=item $netscreen->os_ver()
|
||||||
|
|
||||||
|
|||||||
@@ -280,11 +280,11 @@ Returns 'cisco'
|
|||||||
|
|
||||||
=item $nexus->os()
|
=item $nexus->os()
|
||||||
|
|
||||||
Returns 'nx-os'
|
Returns C<'nx-os'>
|
||||||
|
|
||||||
=item $nexus->os_ver()
|
=item $nexus->os_ver()
|
||||||
|
|
||||||
Returns operating system version extracted fron C<sysDescr>.
|
Returns operating system version extracted from C<sysDescr>.
|
||||||
|
|
||||||
=item $nexus->serial()
|
=item $nexus->serial()
|
||||||
|
|
||||||
@@ -294,7 +294,7 @@ Returns the serial number of the chassis from F<ENTITY-MIB>.
|
|||||||
|
|
||||||
Tries to reference $nexus->id() to F<CISCO-ENTITY-VENDORTYPE-OID-MIB>
|
Tries to reference $nexus->id() to F<CISCO-ENTITY-VENDORTYPE-OID-MIB>
|
||||||
|
|
||||||
Removes 'cevChassis' for readability.
|
Removes C<'cevChassis'> for readability.
|
||||||
|
|
||||||
=item $nexus->mac()
|
=item $nexus->mac()
|
||||||
|
|
||||||
|
|||||||
@@ -175,7 +175,7 @@ These are methods that return scalar value from SNMP
|
|||||||
|
|
||||||
=item $pfront->vendor()
|
=item $pfront->vendor()
|
||||||
|
|
||||||
Returns 'packetfront'.
|
Returns C<'packetfront'>.
|
||||||
|
|
||||||
=item $pfront->os()
|
=item $pfront->os()
|
||||||
|
|
||||||
@@ -187,7 +187,7 @@ Returns the software version extracted from C<sysDescr>.
|
|||||||
|
|
||||||
=item $pfront->serial()
|
=item $pfront->serial()
|
||||||
|
|
||||||
Returns the value of productSerialNo.
|
Returns the value of C<productSerialNo>.
|
||||||
|
|
||||||
=back
|
=back
|
||||||
|
|
||||||
|
|||||||
@@ -199,18 +199,18 @@ These are methods that return scalar values from SNMP
|
|||||||
|
|
||||||
=item $tasman->vendor()
|
=item $tasman->vendor()
|
||||||
|
|
||||||
Returns 'avaya'
|
Returns C<'avaya'>
|
||||||
|
|
||||||
=item $tasman->model()
|
=item $tasman->model()
|
||||||
|
|
||||||
Tries to get the model from C<nnchassisModel> and if not available
|
Tries to get the model from C<nnchassisModel> and if not available
|
||||||
cross references $tasman->id() to F<NT-ENTERPRISE-DATA-MIB>.
|
cross references $tasman->id() to F<NT-ENTERPRISE-DATA-MIB>.
|
||||||
|
|
||||||
Substitutes 'SR' for 'ntSecureRouter' in the name for readability.
|
Substitutes 'SR' for C<'ntSecureRouter'> in the name for readability.
|
||||||
|
|
||||||
=item $tasman->os()
|
=item $tasman->os()
|
||||||
|
|
||||||
Returns 'tasman'
|
Returns C<'tasman'>
|
||||||
|
|
||||||
=item $tasman->os_ver()
|
=item $tasman->os_ver()
|
||||||
|
|
||||||
@@ -250,8 +250,8 @@ Grabs the os version from C<nnsysVersion>
|
|||||||
|
|
||||||
=item $tasman->serial()
|
=item $tasman->serial()
|
||||||
|
|
||||||
Tries both (C<nnchassisOperStatus>) and (C<nnchassisSerialNumber>) as OID's
|
Tries both (C<nnchassisOperStatus>) and (C<nnchassisSerialNumber>) as oid
|
||||||
were redefined between versions.
|
was redefined between versions.
|
||||||
|
|
||||||
=back
|
=back
|
||||||
|
|
||||||
|
|||||||
@@ -161,7 +161,7 @@ These are methods that return scalar value from SNMP
|
|||||||
|
|
||||||
=item $apc->os()
|
=item $apc->os()
|
||||||
|
|
||||||
Returns 'aos'
|
Returns C<'aos'>
|
||||||
|
|
||||||
=item $apc->os_bin()
|
=item $apc->os_bin()
|
||||||
|
|
||||||
@@ -178,7 +178,7 @@ card serial C<POWERNET-MIB::experimental.2.4.1.2.1> into a pretty string.
|
|||||||
|
|
||||||
=item $apc->vendor()
|
=item $apc->vendor()
|
||||||
|
|
||||||
apc
|
Returns C<'apc'>
|
||||||
|
|
||||||
=item $apc->model()
|
=item $apc->model()
|
||||||
|
|
||||||
|
|||||||
@@ -132,7 +132,7 @@ Returns 'juniper'.
|
|||||||
|
|
||||||
=item $neoteris->os()
|
=item $neoteris->os()
|
||||||
|
|
||||||
Returns 'ive'.
|
Returns C<'ive'>.
|
||||||
|
|
||||||
=item $neoteris->os_ver()
|
=item $neoteris->os_ver()
|
||||||
|
|
||||||
|
|||||||
@@ -18,6 +18,7 @@ __DATA__
|
|||||||
5000BH
|
5000BH
|
||||||
accelar
|
accelar
|
||||||
acl
|
acl
|
||||||
|
ADSL
|
||||||
adsl
|
adsl
|
||||||
af
|
af
|
||||||
agere
|
agere
|
||||||
@@ -29,8 +30,10 @@ alcatel
|
|||||||
alteon
|
alteon
|
||||||
Altiga
|
Altiga
|
||||||
altiga
|
altiga
|
||||||
|
anycast
|
||||||
AOS
|
AOS
|
||||||
ap
|
ap
|
||||||
|
APC
|
||||||
APs
|
APs
|
||||||
Arista
|
Arista
|
||||||
arista
|
arista
|
||||||
@@ -43,9 +46,13 @@ ascii
|
|||||||
asn
|
asn
|
||||||
ati
|
ati
|
||||||
attr
|
attr
|
||||||
|
ATUC
|
||||||
|
ATUR
|
||||||
augenstein
|
augenstein
|
||||||
autonegotiate
|
autonegotiate
|
||||||
autospecify
|
autospecify
|
||||||
|
Avaya
|
||||||
|
avaya
|
||||||
baetz
|
baetz
|
||||||
bayrs
|
bayrs
|
||||||
baystack
|
baystack
|
||||||
@@ -62,6 +69,7 @@ bpdus
|
|||||||
BSSID
|
BSSID
|
||||||
bulkrepeaters
|
bulkrepeaters
|
||||||
bulkwalk
|
bulkwalk
|
||||||
|
Bulley
|
||||||
cabletron
|
cabletron
|
||||||
catos
|
catos
|
||||||
cdp
|
cdp
|
||||||
@@ -70,20 +78,26 @@ circuitless
|
|||||||
cisco
|
cisco
|
||||||
cisco's
|
cisco's
|
||||||
ciscovtp
|
ciscovtp
|
||||||
|
Citrix
|
||||||
|
citrix
|
||||||
cli
|
cli
|
||||||
conf
|
conf
|
||||||
config
|
config
|
||||||
contivity
|
contivity
|
||||||
CPAN
|
CPAN
|
||||||
|
CPE
|
||||||
cpu
|
cpu
|
||||||
ctron
|
ctron
|
||||||
cyclades
|
cyclades
|
||||||
|
DataSMART
|
||||||
datatype
|
datatype
|
||||||
deauthenticate
|
deauthenticate
|
||||||
debugsnmp
|
debugsnmp
|
||||||
|
dhcp
|
||||||
dlink
|
dlink
|
||||||
dmitry
|
dmitry
|
||||||
DOCSIS
|
DOCSIS
|
||||||
|
DRG
|
||||||
ds
|
ds
|
||||||
dslam
|
dslam
|
||||||
dslams
|
dslams
|
||||||
@@ -103,14 +117,18 @@ fastiron
|
|||||||
fdb
|
fdb
|
||||||
fdp
|
fdp
|
||||||
fenner
|
fenner
|
||||||
|
FreeBSD
|
||||||
fsm
|
fsm
|
||||||
|
FTOS
|
||||||
FWSM
|
FWSM
|
||||||
fwsm
|
fwsm
|
||||||
gbe
|
gbe
|
||||||
gbesm
|
gbesm
|
||||||
|
Gbps
|
||||||
getnext
|
getnext
|
||||||
Ghz
|
Ghz
|
||||||
gigabit
|
gigabit
|
||||||
|
Gorwits
|
||||||
hartmaier
|
hartmaier
|
||||||
iana
|
iana
|
||||||
ibm
|
ibm
|
||||||
@@ -119,17 +137,21 @@ ieee
|
|||||||
ietf
|
ietf
|
||||||
ifindex
|
ifindex
|
||||||
igmp
|
igmp
|
||||||
|
IgnoreNetSNMPConf
|
||||||
iid
|
iid
|
||||||
iids
|
iids
|
||||||
indices
|
indices
|
||||||
ingen
|
ingen
|
||||||
|
IOS
|
||||||
ios
|
ios
|
||||||
ip
|
ip
|
||||||
IPV
|
IPV
|
||||||
IPv
|
IPv
|
||||||
jeroen
|
jeroen
|
||||||
junos
|
junos
|
||||||
|
Kentrox
|
||||||
kramarov
|
kramarov
|
||||||
|
ladvd
|
||||||
lans
|
lans
|
||||||
linksys
|
linksys
|
||||||
lldp
|
lldp
|
||||||
@@ -152,6 +174,7 @@ mibdirs
|
|||||||
mib
|
mib
|
||||||
mibs
|
mibs
|
||||||
milliwatts
|
milliwatts
|
||||||
|
Mikrotik
|
||||||
msb
|
msb
|
||||||
mtu
|
mtu
|
||||||
multi
|
multi
|
||||||
@@ -165,11 +188,14 @@ ndp
|
|||||||
netdisco
|
netdisco
|
||||||
netgear
|
netgear
|
||||||
netmask
|
netmask
|
||||||
|
Netscaler
|
||||||
|
netscaler
|
||||||
netscreen
|
netscreen
|
||||||
nmm
|
nmm
|
||||||
nopassword
|
nopassword
|
||||||
nortel
|
nortel
|
||||||
nosuch
|
nosuch
|
||||||
|
NX
|
||||||
oem
|
oem
|
||||||
ofdm
|
ofdm
|
||||||
oid
|
oid
|
||||||
@@ -179,8 +205,10 @@ os
|
|||||||
osi
|
osi
|
||||||
ospf
|
ospf
|
||||||
overridable
|
overridable
|
||||||
|
PacketFront
|
||||||
pae
|
pae
|
||||||
petri
|
petri
|
||||||
|
pfSense
|
||||||
phy
|
phy
|
||||||
pinkoski
|
pinkoski
|
||||||
poe
|
poe
|
||||||
@@ -194,17 +222,21 @@ qbridge
|
|||||||
qos
|
qos
|
||||||
queueing
|
queueing
|
||||||
radlan
|
radlan
|
||||||
|
Radware
|
||||||
|
radware
|
||||||
rapidcity
|
rapidcity
|
||||||
readme
|
readme
|
||||||
readonly
|
readonly
|
||||||
rebranded
|
rebranded
|
||||||
retrynosuch
|
retrynosuch
|
||||||
rom
|
rom
|
||||||
|
RouterOS
|
||||||
rtt
|
rtt
|
||||||
rttmon
|
rttmon
|
||||||
sca
|
sca
|
||||||
Schenau
|
Schenau
|
||||||
sergienko
|
sergienko
|
||||||
|
SG
|
||||||
sieborger
|
sieborger
|
||||||
SNMP
|
SNMP
|
||||||
snmp
|
snmp
|
||||||
@@ -213,10 +245,12 @@ snmpv2
|
|||||||
snmpv3
|
snmpv3
|
||||||
snmpwalk
|
snmpwalk
|
||||||
solaris
|
solaris
|
||||||
|
SonicWALL
|
||||||
sonmp
|
sonmp
|
||||||
ssid
|
ssid
|
||||||
SSID's
|
SSID's
|
||||||
SSIDs
|
SSIDs
|
||||||
|
SSL
|
||||||
Stickland
|
Stickland
|
||||||
stackable
|
stackable
|
||||||
stdout
|
stdout
|
||||||
@@ -228,8 +262,10 @@ sunos
|
|||||||
supply's
|
supply's
|
||||||
synoptics
|
synoptics
|
||||||
sys
|
sys
|
||||||
|
Telesis
|
||||||
telesyn
|
telesyn
|
||||||
telesys
|
telesys
|
||||||
|
terabit
|
||||||
tftp
|
tftp
|
||||||
tftpfilename
|
tftpfilename
|
||||||
tftpserver
|
tftpserver
|
||||||
@@ -238,11 +274,13 @@ tmnxModel
|
|||||||
todo
|
todo
|
||||||
tuttle
|
tuttle
|
||||||
ucsc
|
ucsc
|
||||||
|
unicast
|
||||||
uninstall
|
uninstall
|
||||||
uptime
|
uptime
|
||||||
vlan
|
vlan
|
||||||
vlans
|
vlans
|
||||||
vpn
|
vpn
|
||||||
|
VSP
|
||||||
vtp
|
vtp
|
||||||
watanabe
|
watanabe
|
||||||
wlan
|
wlan
|
||||||
|
|||||||
Reference in New Issue
Block a user