# SNMP::Info - Max Baker # $Id$ # # Copyright (c) 2002-3, Regents of the University of California # All rights reserved. # # See COPYRIGHT below package SNMP::Info; $VERSION = 0.2; use strict; use Exporter; use SNMP; use Carp; @SNMP::Info::ISA = qw/Exporter/; @SNMP::Info::EXPORT_OK = qw//; use vars qw/$VERSION %FUNCS %GLOBALS %MIBS %MUNGE $AUTOLOAD $INIT $DEBUG %SPEED_MAP/; $DEBUG=0; =head1 NAME SNMP::Info - Perl5 Interface to Network devices through SNMP. =head1 VERSION SNMP::Info - Version 0.1 =head1 AUTHOR Max Baker (C) SNMP::Info was created for the Netdisco application at UCSC =head1 COPYRIGHT AND LICENCE Copyright (c) 2002-3, Regents of the University of California All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: * Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. * Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. * Neither the name of the University of California, Santa Cruz nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. =head1 SYNOPSIS # Connect with generic Info object my $info = new SNMP::Info( DestHost => 'router' , Community => 'public' ); $name = $info->name(); # Try and find a more specific subclass of SNMP::Info my $object_class = $info->device_type(); my $more_specific_device = new $object_class( 'Desthost' => 'mydevice', 'Community' => 'public'); # Find out the Duplex status for the ports my $interfaces = $more_specific_device->interfaces(); my $i_duplex = $more_specific_device->i_duplex(); foreach my $iid (keys %$interfaces){ my $duplex = $i_duplex->{$iid}; # Print out physical port name, not snmp iid my $port = $interfaces->{$iid}; print "$port : $duplex\n"; } =head1 REQUIREMENTS =over =item 1. Net-SNMP To use this module, you must have Net-SNMP installed on your system. Net-SNMP can be found at http://net-snmp.sourceforge.net . Version 5.0.2 or greater is recommended. The Perl module C is found inside the distribution. Go to the F directory and install it from there, or run C<./configure --with-perl-modules> . =item 2. MIBS Each sub-module that you use will also require specific MIBs, usually obtainable on the net. See the list above for a quick glance, and the documentation in each sub module for more information. Make sure that your snmp.conf is updated to point to your MIB directory and that the MIBs are world-readable. SNMP::Info requires RFC1213-MIB (and whatever supporting MIBs that are referenced). A good starting point are the Version 2 MIBs from Cisco, found at ftp://ftp.cisco.com/pub/mibs/v2/v2.tar.gz Run C to install them. Then run C and setup that directory as default. Move F into F when you are done. =back =head1 DESCRIPTION SNMP::Info gives an object oriented interface to information obtained through SNMP. This module is geared towards network devices. Speciality sub-classes exist for a number of vendors and products (see below). =head2 Design Goals =over =item 1. Use of MIB variables and values instead of purely numeric OID All values are retrieved via MIB Leaf node names. This means that SNMP::Info only asks SNMP::Session to look for ``sysName'' instead of 1.3.6.1.2.1.1.5. It also means that you need to download MIB files for each sub module that you use. The other side effect to using MIBs is data results come back as meaningful text, instead of integers. Instead of looking up 1.3.6.1.2.1.2.2.1.3 and getting back C<23> SNMP::Info will ask for C and will get back C. =item 2. SNMP::Info is easily extended to new devices You can create a new sub class for a device by filling in Four hashes %GLOBALS, %MIBS, %FUNCS, and %MUNGE with the names of the SNMP attributes that are specific to your device. See the bottom of this document for a sample Sub Class. When you make a new sub class for a device, please be sure to send it back to the developers at snmp@warped.org for inclusion in the next version. =back =head1 Sub Classes =over =item SNMP::Info::Bridge =item SNMP::Info::CDP =item SNMP::Info::EtherLike =item SNMP::Info::MAU =item SNMP::Info::Layer1 =item SNMP::Info::Layer2 =item SNMP::Info::Layer3 =item SNMP::Info::Layer1::Allied =item SNMP::Info::Layer1::Asante =item SNMP::Info::Layer2::Bay =item SNMP::Info::Layer2::C1900 =item SNMP::Info::Layer2::C2900 =item SNMP::Info::Layer2::Catalyst =item SNMP::Info::Layer2::HP =item SNMP::Info::Layer3::Aironet =item SNMP::Info::Layer3::Foundry =back =head2 Details =over =item * SNMP::Info::Bridge - BRIDGE-MIB - RFC1286 Support Requires BRIDGE-MIB =item * SNMP::Info::CDP - Cisco Discovery Protocol (CDP) Support. Provides Layer 2 Topology Information on Cisco and some HP Devices. Requires CISCO-CDP-MIB =item * SNMP::Info::EtherLike Requires ETHERLIKE-MIB - RFC1398 =item * SNMP::Info::Layer1 - Generic Layer 1 Device Support Requires Standard V1 and V2 MIBs =item * SNMP::Info::Layer2 - Generic Layer 2 Device Support Inherits: SNMP::Info::CDP SNMP::Info::Bridge Required MIBs: CISCO-PRODUCTS-MIB - Gives model information for Cisco HP-ICF-OID - Gives model information for HPs =item * SNMP::Info::Layer3 - Generic Layer 3 and Layer 2/3 Device Support Inherits: SNMP::Info::Bridge - For Layer 2/3 devices SNMP::Info::CDP SNMP::Info::EtherLike Required MIBs: CISCO-PRODUCTS-MIB - Gives model information for Cisco HP-ICF-OID - Gives model information for HPs ENTITY-MIB - Gives some chassis information OSPF-MIB - Gives router information =item * SNMP::Info::MAU - RFC2668 - Media Access Unit (MAU) MAU-MIB =item * SNMP::Info::Layer1::Allied - Allied TeleSys Hub Support Requires ATI-MIB - Allied Devices MIB downloadable from http://www.allied-telesyn.com/allied/support/ =item * SNMP::Info::Layer1::Asante - Asante 1012 Hubs Requires ASANTE-HUB1012-MIB - Download from http://www.mibdepot.com =item * SNMP::Info::Layer2::Bay - Bay Networks BayStack Switch Support Required MIBs: SYNOPTICS-ROOT-MIB - Gives model information for Bay S5-ETH-MULTISEG-TOPOLOGY-MIB - Gives Layer 2 topology information for Bay Other supporting MIBs needed, see SNMP::Info::Bay for more info =item * SNMP::Info::Layer2::C1900 - Cisco 1900 and 1900c Device Support Requires STAND-ALONE-ETHERNET-SWITCH-MIB (ESSWITCH-MIB) =item * SNMP::Info::Layer2::C2900 - Cisco 2900 Series Device Support. Requires CISCO-C2900-MIB =item * SNMP::Info::Layer2::Catalyst - Cisco Catalyst WSC Series Switch Support Requires MIBs: CISCO-STACK-MIB CISCO-VTP-MIB =item * SNMP::Info::Layer2::HP - HP Procurve Switch Support Inherits: SNMP::Info::MAU Required MIBs: ENTITY-MIB RFC1271-MIB HP-ICF-OID =item * SNMP::Info::Layer3::Aironet - Cisco Aironet Wireless Access Points (AP) Support Required MIBs: AWCVX-MIB - Aironet Specific MIB values IEEE802dot11-MIB - IEEE 802.11 Specific MIB (currently draft) =item * SNMP::Info::Layer3::Foundry - Older Foundry Networks Devices Support Inherits SNMP::Info::Bridge Requires FOUNDRY-SN-ROOT-MIB - Foundry specific values. See SNMP::Info::Layer3::Foundry for more information. =back =head1 METHODS These are generic methods from RFC1213. Some subset of these is probably available for any network device that speaks SNMP. =head2 Constructor =over =item new() Creates a new object and connects via SNMP::Session. Arguments given are passed to SNMP::Session and can be used to overide defaults. =cut sub new { my $class = shift; my %args = @_; my $new_obj = {}; bless $new_obj,$class; $new_obj->{_class} = $class; # load references to all the subclass data structures { no strict 'refs'; $new_obj->{_init} = \${$class . '::INIT'}; $new_obj->{_mibs} = \%{$class . '::MIBS'}; $new_obj->{_globals} = \%{$class . '::GLOBALS'}; $new_obj->{_funcs} = \%{$class . '::FUNCS'}; $new_obj->{_munge} = \%{$class . '::MUNGE'}; } # SNMP version $new_obj->{_version} = $args{Version}; $new_obj->{_community} = $args{Community}; # Initialize mibs if not done my $init_ref = $new_obj->{_init}; unless ( $$init_ref ) { $new_obj->init(); $$init_ref=1; } # These session defaults can be overwritten with @_ my $sess = new SNMP::Session( #'Version' => 2, 'UseEnums' => 1, %args ); unless (defined $sess){ # How do i get error messages back from SNMP? #print $SNMP::ErrorStr; return undef; } $new_obj->{sess} = $sess; my $store = {}; $new_obj->{store} = $store; return $new_obj; } =back =head2 Data is Cached A call to any of these methods will load the data once, and then return cached versions of that data. Use load_METHOD() to reload from the device $data = $cdp->c_ip(); ... $cdp->load_c_ip(); $newdata = $cdp->c_ip(); =head2 Scalar Methods =over =item $info->device_type() Returns the SubClass name for this device. C is returned if no more specific class is available. First the device is checked for Layer 3 support and a specific subclass, then Layer 2 support and subclasses are checked for. This means that Layer 2 / 3 switches and routers will fall under the SNMP::Info::Layer3 subclasses. If the device still can be connected to via SNMP::Info, then SNMP::Info is returned. Algorithm for SubClass Detection: Layer3 Support -> SNMP::Info::Layer3 Aironet -> SNMP::Info::Layer3::Aironet Catalyst 3550 -> SNMP::Info::Layer3::C3550 Foundry -> SNMP::Info::Layer3::Foundry Elsif Layer2 (no Layer3) -> SNMP::Info::Layer2 Bay Networks -> SNMP::Info::Layer2::Bay Catalyst 1900 -> SNMP::Info::Layer2::C1900 Catalyst 2900XL (IOS) -> SNMP::Info::Layer2::C2900 Catalyst WS-C (2926,5xxx,6xxx) -> SNMP::Info::Layer2::Catalyst HP Procurve -> SNMP::Info::Layer2::HP Elsif Layer1 Support -> SNMP::Info::Layer1 Allied -> SNMP::Info::Layer1::Allied Asante -> SNMP::Info::Layer1::Asante Else -> SNMP::Info =cut sub device_type { my $info = shift; my $objtype = "SNMP::Info"; my $layers = $info->layers(); my $desc = $info->description(); # if we dont have sysServices, we dont have anything else either probably. return undef unless (defined $layers and length($layers)); # Layer 3 Supported # (usually has layer2 as well, so we check for 3 first) if ($info->has_layer(3)) { $objtype = 'SNMP::Info::Layer3'; # Device Type Overrides return $objtype unless (defined $desc and length($desc)); $objtype = 'SNMP::Info::Layer3::C3550' if $desc =~ /C3550/ ; $objtype = 'SNMP::Info::Layer3::Foundry' if $desc =~ /foundry/i ; $objtype = 'SNMP::Info::Layer3::Aironet' if ($desc =~ /cisco/i and $desc =~ /\D3[45]0\D/) ; # Layer 2 Supported } elsif ($info->has_layer(2)) { $objtype = 'SNMP::Info::Layer2'; return $objtype unless (defined $desc and $desc !~ /^\s*$/); # Device Type Overrides # Catalyst 1900 series override $objtype = 'SNMP::Info::Layer2::C1900' if ($desc =~ /catalyst/i and $desc =~ /\D19\d{2}/); # Catalyst 2900 (IOS) series override $objtype = 'SNMP::Info::Layer2::C2900' if ($desc =~ /C2900XL/i ); # Catalyst WS-C series override (2926,5xxx,6xxx) $objtype = 'SNMP::Info::Layer2::Catalyst' if ($desc =~ /WS-C\d{4}/); # HP $objtype = 'SNMP::Info::Layer2::HP' if ($desc =~ /hp/i); # Bay Switch $objtype = 'SNMP::Info::Layer2::Bay' if ($desc =~ /bay/i); } elsif ($info->has_layer(1)) { $objtype = 'SNMP::Info::Layer1'; # Allied crap-o-hub $objtype = 'SNMP::Info::Layer1::Allied' if ($desc =~ /allied/i); $objtype = 'SNMP::Info::Layer1::Asante' if ($desc =~ /asante/i); } return $objtype; } =item $info->has_layer(3) Returns non-zero if the device has the supplied layer in the OSI Model Returns C if the device doesn't support the layers() call. =cut sub has_layer { my $self = shift; my $check_for = shift; my $layers = $self->layers(); return undef unless defined $layers; return undef unless length($layers); return substr($layers,8-$check_for, 1); } =item $info->uptime() Uptime in hundreths of seconds since device became available. (B) =item $info->contact() (B) =item $info->name() (B) =item $info->location() (B) =item $info->layers() This returns a binary encoded string where each digit represents a layer of the OSI model served by the device. eg: 01000010 means layers 2 (physical) and 7 (Application) are served. Note: This string is 8 digits long. (B) =item $info->ports() Number of interfaces available on this device. (B) =back =head2 Table Methods Each of these methods returns a hash_reference to a hash keyed on the interface index in SNMP. Example : $cdp->c_ip() returns { '304' => '123.123.231.12' } =head3 Interfaces =over =item $info->interfaces() This methods is overriden in each subclass to provide a mapping between the Interface Table Index (iid) and the physical port name. =item $info->if_ignore() Returns a reference to a hash where key values that exist are interfaces to ignore. Ignored interfaces are ones that are usually not Physical ports or Virtual Lans (VLANs) such as the Loopback interface, or the CPU interface. SNMP::Info and it's subclasses tries to provide data on Physical ports. =cut sub if_ignore { my %nothing; return \%nothing; } =item $info->i_index() Defaults to $info->interfaces() (B) =item $info->i_description() Returns reference to hash keyed by iid. Values are the Textual Description of the interface (port). Usually the physical / human-friendly name. (B) =item $info->i_type() Returns reference to hash keyed by iid. Values are the port type, such as Vlan, 10baseT, Ethernet, Serial... (B) =item $info->i_mtu() Returns reference to hash keyed by iid. Values are the MTU value for the port. (B) =item $info->i_speed() Returns reference to hash keyed by iid. Values are the speed of the link. (B) =item $info->i_mac() Returns reference to hash keyed by iid. Values are the MAC address of the interface. Note this is just the MAC of the port, not anything connected to it. (B) =item $info->i_up() Returns reference to hash keyed by iid. Values are the Link Status of the interface. Typical values are 'up' and 'down'. (B) =item $info->i_up_admin() Returns reference to hash keyed by iid. Values are the administrative status of the port. Typical values are 'enabled' and 'disabled'. (B) =item $info->i_name() Returns reference to hash keyed by iid. Values are the Interface Name field. Supported by a smaller subset of devices, this fields is often human set. (B) =item $info->i_alias() Returns reference to hash keyed by iid. Values are a differnent version of the Interface Description or Interface Name. For certain devices this is a more human friendly form of i_description() . For others it is a human set field like i_name(). (B) =back =head3 IP Address Table Each entry in this table is an IP address in use on this device. Usually this is implemented in Layer3 Devices. =over =item $info->ip_index() Maps the IP Table to the IID (B) =item $info->ip_table() Maps the Table to the IP address (B) =item $info->ip_netmask() Gives netmask setting for IP table entry. (B) =item $info->ip_broadcast() Gives broadcast address for IP table entry. (B) =back =head2 Default %MUNGE ip -> &munge_ip mac -> &munge_mac i_mac -> &munge_mac layers -> &munge_dec2bin =cut =head1 CREATING SUBCLASSES =head2 Data Structures Used in SNMP::Info and SubClasses A class inheriting this class must implement these data structures : =over =item $INIT Used to flag if the MIBs have been loaded yet. =cut $INIT = 0; =item %GLOBALS Contains a hash in the form ( method_name => SNMP iid name ) These are scalar values such as name,uptime, etc. When choosing the name for the methods, be aware that other new Sub Modules might inherit this one to get it's features. Try to choose a prefix for methods that will give it's own name space inside the SNMP::Info methods. =cut %GLOBALS = ( # from SNMPv2-MIB 'id' => 'sysObjectID', 'description' => 'sysDescr', 'uptime' => 'sysUpTime', 'contact' => 'sysContact', 'name' => 'sysName', 'location' => 'sysLocation', 'layers' => 'sysServices', 'ports' => 'ifNumber', ); =item %FUNCS Contains a hash in the form ( method_name => SNMP iid) These are table entries, such as the IfIndex =cut %FUNCS = ( 'interfaces' => 'ifIndex', # from SNMPv2-MIB 'i_index' => 'ifIndex', 'i_description' => 'ifDescr', 'i_type' => 'ifType', 'i_mtu' => 'ifMtu', 'i_speed' => 'ifSpeed', 'i_mac' => 'ifPhysAddress', 'i_up' => 'ifOperStatus', 'i_up_admin' => 'ifAdminStatus', 'i_name' => 'ifName', 'i_alias' => 'ifAlias', # IP Address Table 'ip_index' => 'ipAdEntIfIndex', 'ip_table' => 'ipAdEntAddr', 'ip_netmask' => 'ipAdEntNetMask', 'ip_broadcast' => 'ipAdEntBcastAddr', ); =item %MIBS A list of each mib needed. ('MIB-NAME' => 'itemToTestForPresence') The value for each entry should be a MIB object to check for to make sure that the MIB is present and has loaded correctly. $info->init() will throw an exception if a MIB does not load. =cut %MIBS = ('RFC1213-MIB' => 'sysName'); =item %MUNGE A map between method calls (from %FUNCS or %GLOBALS) and sub routine methods. The subroutine called will be passed the data as it gets it from SNMP and it should return that same data in a more human friendly format. =cut %MUNGE = ('ip' => \&munge_ip, 'mac' => \&munge_mac, 'i_mac' => \&munge_mac, 'layers' => \&munge_dec2bin, 'i_speed'=> \&munge_speed ); =back =head2 Sample Sub Class Let's make a sample Layer 2 Device subclass : # SNMP::Info::Layer2::Sample package SNMP::Info::Layer2::Sample; $VERSION = 0.1; use strict; use Exporter; use SNMP::Info::Layer2; @SNMP::Info::Layer2::Sample::ISA = qw/SNMP::Info::Layer2 Exporter/; @SNMP::Info::Layer2::Sample::EXPORT_OK = qw//; use vars qw/$VERSION %FUNCS %GLOBALS %MIBS %MUNGE $AUTOLOAD $INIT $DEBUG/; %MIBS = (%SNMP::Info::Layer2::MIBS, 'SUPER-DOOPER-MIB' => 'supermibobject' ); %GLOBALS = (%SNMP::Info::Layer2::GLOBALS, 'name' => 'supermib_supername', 'favorite_color' => 'supermib_fav_color_object', 'favorite_movie' => 'supermib_fav_movie_val' ); %FUNCS = (%SNMP::Info::Layer2::FUNCS, # Super Dooper MIB - Super Hero Table 'super_hero_index' => 'SuperHeroIfIndex', 'super_hero_name' => 'SuperHeroIfName', 'super_hero_powers' => 'SuperHeroIfPowers' ); %MUNGE = (%SNMP::Info::Layer2::MUNGE, 'super_hero_powers' => \&munge_powers ); # OverRide uptime() method from %SNMP::Info::GLOBALS sub uptime { my $sample = shift; my $name = $sample->name(); # this is silly but you get the idea return '600' if defined $name ; } # Create our own munge function sub munge_powers { my $power = shift; # Take the returned obscure value and return something useful. return 'Fire' if $power =~ /reallyhot/i; return 'Ice' if $power =~ /reallycold/i; # Else return $power; } # Add Copious Documentation here!!! Be sure and send the debugged version to snmp@warped.org to be included in the next version of SNMP::Info. =head2 Data Munging Callback Subs =over =item munge_speed() Makes human friendly speed ratings using %SPEED_MAP %SPEED_MAP = ( '64000' => '64 kbps', '1500000' => '1.5 Mbps', '1544000' => 'T1', '2000000' => '2.0 Mbps', '2048000' => '2.048 Mbps', '4000000' => '4.0 Mbps', '10000000' => '10 Mbps', '11000000' => '11 Mbps', '20000000' => '20 Mbps', '16000000' => '16 Mbps', '45000000' => 'DS3', '45045000' => 'DS3', '64000000' => '64 Mbps', '100000000' => '100 Mbps', '149760000' => 'OC-1' '155000000' => 'OC-1' '400000000' => '400 Mbps', '622000000' => 'OC-12', '599040000' => 'OC-12', '1000000000' => '1.0 Gbps', ); =cut %SPEED_MAP = ( '64000' => '64 kbps', '1500000' => '1.5 Mbps', '1544000' => 'T1', '2000000' => '2.0 Mbps', '2048000' => '2.048 Mbps', '4000000' => '4.0 Mbps', '10000000' => '10 Mbps', '11000000' => '11 Mbps', '20000000' => '20 Mbps', '16000000' => '16 Mbps', '45000000' => '45 Mbps', '45045000' => 'DS3', '64000000' => '64 Mbps', '100000000' => '100 Mbps', '149760000' => 'OC-1', '155000000' => 'OC-1', '400000000' => '400 Mbps', '622000000' => 'OC-12', '599040000' => 'OC-12', '1000000000' => '1.0 Gbps', ); sub munge_speed { my $speed = shift; return defined $SPEED_MAP{$speed} ? $SPEED_MAP{$speed} : $speed; } =item munge_ip() Takes a binary IP and makes it dotted ASCII =cut sub munge_ip { my $ip = shift; return join('.',unpack('C4',$ip)); } =item munge_mac() Takes an octet stream (HEX-STRING) and returns a colon separated ASCII hex string. =cut sub munge_mac { my $mac = shift; return undef unless defined $mac; return undef unless length $mac; return join(':',map { sprintf "%02x",$_ } unpack('C*',$mac)); } =item munge_octet2hex() Takes a binary octet stream and returns an ASCII hex string =cut sub munge_octet2hex { my $oct = shift; return join('',map {sprintf "%x",$_} unpack('C*',$oct)); } =item munge_dec2bin() Takes a binary char and returns its ASCII binary representation =cut sub munge_dec2bin { my $num = shift; return undef unless defined $num; #return undef unless length($num); $num = unpack("B32",pack("N",$num)); # return last 8 characters only $num =~ s/.*(.{8})$/$1/; return $num } =item munge_bits Takes a SNMP2 'BITS' field and returns the ASCII bit string =cut sub munge_bits { my $bits = shift; return undef unless defined $bits; return unpack("b*",$bits); } =back =head2 Internaly Used Functions =over =item $info->init() Used internally. Loads all entries in %MIBS. =cut sub init { my $self = shift; my $ver = $self->{_version}; if (defined $ver and $ver == 1){ # do nothing } &SNMP::initMib; my $version = $SNMP::VERSION; my ($major,$minor,$rev) = split('\.',$version); if ($major < 5){ # Seems to work under 4.2.0 } elsif ($major == 5 and $minor == 0 and $rev < 2){ carp("SNMP 5.0.1 seems to be rather buggy. Upgrade.\n"); # This is a bug in net-snmp 5.0.1 perl module # see http://groups.google.com/groups?th=47aed6bf7be6a0f5 &SNMP::init_snmp("perl"); } my $mibs = $self->mibs(); foreach my $mib (keys %$mibs){ &SNMP::loadModules("$mib"); unless (defined $SNMP::MIB{$mibs->{$mib}}){ croak "The $mib did not load. See README for $self->{_class}\n"; } } } =item $info->debug(1) Turns on debugging info for this class and SNMP =cut sub debug { my $self = shift; my $debug = shift; $DEBUG=$debug; $SNMP::debugging=$debug; } =item $info->class() Returns the class name of the object. =cut sub class { my $self=shift; return $self->{_class}; } =item $info->funcs() Returns a reference to the %FUNCS hash. =cut sub funcs { my $self=shift; return $self->{_funcs}; } =item $info->mibs() Returns a reference to the %MIBS hash. =cut sub mibs { my $self=shift; return $self->{_mibs}; } =item $info->globals() Returns a reference to the %GLOBALS hash. =cut sub globals { my $self=shift; return $self->{_globals}; } =item $info->munge() Returns a reference ot the %MUNGE hash. =cut sub munge { my $self=shift; return $self->{_munge}; } =item $info->session() Gets or Sets the SNMP::Session object. =cut sub session { my $self = shift; $self->{sess} = $_[0] if @_; return $self->{sess}; } =back =head3 Functions for SNMP Scalars (%GLOBALS) =over =item $info->_global() Used internally by AUTOLOAD to load dynmaic methods from %GLOBALS. Example: $info->name() calls autoload which calls $info->_global('name'). =cut sub _global{ my $self = shift; my $attr = shift; my $sess = $self->{sess}; return undef unless defined $sess; my $globals = $self->globals(); my $oid = $globals->{$attr}; # Tag on .0 unless the leaf ends in .number unless ($oid =~ /\.\d+$/) { $oid .= ".0"; } $DEBUG and print "SNMP::Info::_global $attr : $oid\n"; my $val = $sess->get($oid); # Get the callback hash for data munging my $munge = $self->munge(); # Data Munging if (defined $munge->{$attr}){ my $subref = $munge->{$attr}; $val = &$subref($val); } return $val; } =item $info->_set(attr,val,iid) Used internally by AUTOLOAD to run an SNMP set command for dynamic methods listed in either %GLOBALS or %FUNCS. Example: $info->set_name('dog',3) uses autoload to resolve to $info->_set('name','dog',3); =cut sub _set { my ($self,$attr,$val,$iid) = @_; $iid = defined $iid ? $iid : '.0'; # prepend dot if necessary to $iid $iid = ".$iid" unless $iid =~ /^\./; my $sess = $self->{sess}; return undef unless defined $sess; my $funcs = $self->funcs(); my $globals = $self->globals(); my $oid = undef; # Lookup oid $oid = $globals->{$attr} if defined $globals->{$attr}; $oid = $funcs->{$attr} if defined $funcs->{$attr}; unless (defined $oid) { print "SNMP::Info::_set($attr,$val) - Failed to find $attr in \%GLOBALS or \%FUNCS \n"; return undef; } $oid .= $iid; print "SNMP::Info::_set $attr$iid ($oid) = $val\n" if $DEBUG; my $rv = $sess->set($oid,$val); return $rv; } =back =head3 Functions for SNMP Tables (%FUNCS) =over =item $info->load_all() Runs $info->load_METHOD() for each entry in %FUNCS. Returns { iid => values_hash } where value_hash is in the format: { attribute => value } =cut sub load_all { my $self = shift; my $sess = $self->{sess}; return undef unless defined $sess; my $funcs = $self->funcs(); foreach my $attrib (keys %$funcs) { $attrib = "load_$attrib"; $self->$attrib(); } $self->{_all}++; return $self->{store} if defined wantarray; } =item $info->all() Runs $info->load_all() once then returns the cached data. Use $info->load_all() to reload the data. =cut sub all { my $self = shift; my $sess = $self->{sess}; return undef unless defined $sess; $self->load_all() unless defined $self->{_all}; return $self->{store}; } =item $info->_load_attr() Used internally by AUTOLOAD to fetch data called from methods listed in %FUNCS. Called from $info->load_METHOD(); =cut sub _load_attr { my $self = shift; my ($attr,$leaf) = @_; my $sess = $self->{sess}; my $store = $self->{store}; return undef unless defined $sess; # Get the callback hash for data munging my $munge = $self->munge(); $DEBUG and print "SNMP::Info::_load_attr $attr : $leaf\n"; my $var = new SNMP::Varbind([$leaf]); while (! $sess->{ErrorNum} ){ $sess->getnext($var); last if $var->[0] ne $leaf; my $iid = $var->[1]; my $val = $var->[2]; unless (defined $iid){ $DEBUG and print "SNMP::Info::_load_attr: $attr not here\n"; next; } # Data Munging # Checks for an entry in %munge and runs the subroutine if (defined $munge->{$attr}){ my $subref = $munge->{$attr}; $val = &$subref($val); } $store->{$iid}->{$attr}=$val; } # mark data as loaded $self->{"_${attr}"}++; } =item $info->_show_attr() Used internaly by AUTOLOAD to return data called by methods listed in %FUNCS. Called like $info->METHOD(). The first time ran, it will call $info->load_METHOD(). Every time after it will return cached data. =cut sub _show_attr { my $self = shift; my $attr = shift; my $store = $self->{store}; return undef unless (scalar keys %$store); my %ret_hash; foreach my $iid (keys %$store){ next unless (defined $store->{$iid}->{$attr}); my $val = $store->{$iid}->{$attr}; $ret_hash{$iid}= $val; } return \%ret_hash; } =back =head2 AUTOLOAD Each entry in either %FUNCS or %GLOBALS is used by AUTOLOAD() to create dynamic methods. First Autoload sees if the method name is listed in either of the two hashes. If the method exists in globals, it runs $info->_global(method). Next it will check %FUNCS, run $info->_load_attr(method) if needed and return $info->_show_attr(method). Override any dynamic method listed in one of these hashes by creating a sub with the same name. Example : Override $info->name() by creating `` sub name {}'' in your Module. =cut sub AUTOLOAD { my $self = shift; my $sub_name = $AUTOLOAD; return if $sub_name =~ /DESTROY$/; # package is the first part (my $package = $sub_name) =~ s/[^:]*$//; # Sub name is the last part $sub_name =~ s/.*://; my $attr = $sub_name; $attr =~ s/^(load|set)_//; # Let's use the %GLOBALS and %FUNCS from the class that # inherited us. my (%funcs,%globals); { no strict 'refs'; %funcs = %{$package.'FUNCS'}; %globals = %{$package.'GLOBALS'}; } unless( defined $funcs{$attr} or defined $globals{$attr} ) { #print "$attr not found in ",join(',',keys %funcs),"\n"; return; } # Check for load_ ing. if ($sub_name =~ /^load_/){ $self->_load_attr( $attr,$funcs{$attr} ); return $self->_show_attr( $attr ) if defined wantarray; } if ($sub_name =~ /^set_/){ return $self->_set( $attr, @_); } # First check %GLOBALS and return _scalar(global) if (defined $globals{$attr} ){ return $self->_global( $attr ); } # Otherwise we must be listed in %FUNCS # Load data if not already cached $self->_load_attr( $attr, $funcs{$attr} ) unless defined $self->{"_${attr}"}; return $self->_show_attr($attr); } 1;