# SNMP::Info::Layer3::Foundry - SNMP Interface to Foundry devices # $Id$ # # Copyright (c) 2008 Max Baker changes from version 0.8 and beyond. # # Copyright (c) 2002,2003 Regents of the University of California # All rights reserved. # # Redistribution and use in source and binary forms, with or without # modification, are permitted provided that the following conditions are met: # # * Redistributions of source code must retain the above copyright notice, # this list of conditions and the following disclaimer. # * Redistributions in binary form must reproduce the above copyright # notice, this list of conditions and the following disclaimer in the # documentation and/or other materials provided with the distribution. # * Neither the name of the University of California, Santa Cruz nor the # names of its contributors may be used to endorse or promote products # derived from this software without specific prior written permission. # # THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" # AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE # IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE # ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE # LIABLE FOR # ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR # CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF # SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS # INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN # CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) # ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE # POSSIBILITY OF SUCH DAMAGE. package SNMP::Info::Layer3::Foundry; use strict; use Exporter; use SNMP::Info::Layer3; use SNMP::Info::FDP; use SNMP::Info::LLDP; @SNMP::Info::Layer3::Foundry::ISA = qw/SNMP::Info::FDP SNMP::Info::LLDP SNMP::Info::Layer3 Exporter/; @SNMP::Info::Layer3::Foundry::EXPORT_OK = qw//; use vars qw/$VERSION %GLOBALS %FUNCS %MIBS %MUNGE/; $VERSION = '3.00_001'; %MIBS = ( %SNMP::Info::Layer3::MIBS, %SNMP::Info::LLDP::MIBS, %SNMP::Info::FDP::MIBS, 'FOUNDRY-SN-ROOT-MIB' => 'foundry', 'FOUNDRY-SN-AGENT-MIB' => 'snChasPwrSupplyDescription', 'FOUNDRY-SN-SWITCH-GROUP-MIB' => 'snSwGroupOperMode', ); %GLOBALS = ( %SNMP::Info::Layer3::GLOBALS, %SNMP::Info::LLDP::GLOBALS, %SNMP::Info::FDP::GLOBALS, 'mac' => 'ifPhysAddress.1', 'chassis' => 'entPhysicalDescr.1', 'temp' => 'snChasActualTemperature', 'ps1_type' => 'snChasPwrSupplyDescription.1', 'ps1_status' => 'snChasPwrSupplyOperStatus.1', 'fan' => 'snChasFanOperStatus.1', 'img_ver' => 'snAgImgVer', 'ch_serial' => 'snChasSerNum', ); %FUNCS = ( %SNMP::Info::Layer3::FUNCS, %SNMP::Info::LLDP::FUNCS, %SNMP::Info::FDP::FUNCS, # FOUNDRY-SN-SWITCH-GROUP-MIB # snSwPortInfoTable - Switch Port Information Group 'sw_index' => 'snSwPortIfIndex', 'sw_duplex' => 'snSwPortInfoChnMode', 'sw_type' => 'snSwPortInfoMediaType', 'sw_speed' => 'snSwPortInfoSpeed', ); %MUNGE = ( %SNMP::Info::Layer3::MUNGE, %SNMP::Info::LLDP::MUNGE, %SNMP::Info::FDP::MUNGE, ); sub i_ignore { my $foundry = shift; my $partial = shift; my $interfaces = $foundry->interfaces($partial) || {}; my %i_ignore; foreach my $if ( keys %$interfaces ) { if ( $interfaces->{$if} =~ /(tunnel|loopback|\blo\b|lb|null)/i ) { $i_ignore{$if}++; } } return \%i_ignore; } sub i_duplex { my $foundry = shift; my $partial = shift; my $sw_index = $foundry->sw_index($partial); my $sw_duplex = $foundry->sw_duplex($partial); unless ( defined $sw_index and defined $sw_duplex ) { return $foundry->SUPER::i_duplex(); } my %i_duplex; foreach my $sw_port ( keys %$sw_duplex ) { my $iid = $sw_index->{$sw_port}; my $duplex = $sw_duplex->{$sw_port}; next if $duplex =~ /none/i; $i_duplex{$iid} = 'half' if $duplex =~ /half/i; $i_duplex{$iid} = 'full' if $duplex =~ /full/i; } return \%i_duplex; } sub model { my $foundry = shift; my $id = $foundry->id(); my $model = &SNMP::translateObj($id); # EdgeIron if ( $id =~ /\.1991\.1\.[45]\./ ) { my $e_name = $foundry->e_name(); # Find entity table entry for "unit.1" my $unit_iid = undef; foreach my $e ( keys %$e_name ) { my $name = $e_name->{$e} || ''; $unit_iid = $e if $name eq 'unit.1'; } # Find Model Name my $e_model = $foundry->e_model(); if ( defined $e_model->{$unit_iid} ) { return $e_model->{$unit_iid}; } } return $id unless defined $model; $model =~ s/^sn//; return $model; } sub os { return 'brocade'; } sub vendor { return 'brocade'; } sub os_ver { my $foundry = shift; return $foundry->img_ver() if ( defined $foundry->img_ver() ); # Some older ones don't have this value,so we cull it from the description my $descr = $foundry->description(); if ( $descr =~ m/Version (\d\S*)/ ) { return $1; } # EdgeIron my $e_name = $foundry->e_name(); # find entity table entry for "stackmanaget.1" my $unit_iid = undef; foreach my $e ( keys %$e_name ) { my $name = $e_name->{$e} || ''; $unit_iid = $e if $name eq 'stackmanaget.1'; } if ( defined $unit_iid ) { # Find Model Name my $e_fwver = $foundry->e_fwver(); if ( defined $e_fwver->{$unit_iid} ) { return $e_fwver->{$unit_iid}; } } # See if we report from Flash if wouldn't report from running above return $foundry->snAgFlashImgVer() if ( defined $foundry->snAgFlashImgVer() ); # Last resort return $foundry->SUPER::os_ver(); } sub serial { my $foundry = shift; # Return chassis serial number if available return $foundry->ch_serial() if ( $foundry->ch_serial() ); # If no chassis serial use first module serial my $mod_serials = $foundry->snAgentConfigModuleSerialNumber() || {}; foreach my $mod ( sort keys %$mod_serials ) { my $serial = $mod_serials->{$mod} || ''; next unless defined $serial; return $serial; } # EdgeIron my $e_name = $foundry->e_name(); # find entity table entry for "unit.1" my $unit_iid = undef; foreach my $e ( keys %$e_name ) { my $name = $e_name->{$e} || ''; $unit_iid = $e if $name eq 'unit.1'; } if ( defined $unit_iid ) { # Look up serial of found entry. my $e_serial = $foundry->e_serial(); return $e_serial->{$unit_iid} if defined $e_serial->{$unit_iid}; } # Last resort return $foundry->SUPER::serial(); } sub interfaces { my $foundry = shift; my $partial = shift; my $i_descr = $foundry->i_description($partial) || {}; my $i_name = $foundry->i_name($partial) || {}; # Use ifName for EdgeIrons else use ifDescr foreach my $iid ( keys %$i_name ) { my $name = $i_name->{$iid}; next unless defined $name; $i_descr->{$iid} = $name if $name =~ /^port\d+/i; } return $i_descr; } # Reported hangs on a EdgeIron 24G sub stp_p_state { my $foundry = shift; my $partial = shift; my $descr = $foundry->description(); if ( $descr =~ m/\bEdgeIron 24G\b/ ) { return; } return $foundry->SUPER::stp_p_state($partial) || {}; } 1; __END__ =head1 NAME SNMP::Info::Layer3::Foundry - SNMP Interface to Brocade (Foundry) Network Devices =head1 AUTHOR Max Baker =head1 SYNOPSIS # Let SNMP::Info determine the correct subclass for you. my $foundry = new SNMP::Info( AutoSpecify => 1, Debug => 1, DestHost => 'myswitch', Community => 'public', Version => 1 ) or die "Can't connect to DestHost.\n"; my $class = $foundry->class(); print "SNMP::Info determined this device to fall under subclass : $class\n"; =head1 DESCRIPTION Abstraction subclass for Brocade (Foundry) Networks devices. For speed or debugging purposes you can call the subclass directly, but not after determining a more specific class using the method above. my $foundry = new SNMP::Info::Layer3::Foundry(...); =head2 Inherited Classes =over =item SNMP::Info::Layer3; =item SNMP::Info::FDP; =item SNMP::Info::LLDP; =back =head2 Required MIBs =over =item F =item F =item F =item Inherited Classes' MIBs See L for its own MIB requirements. See L for its own MIB requirements. See L for its own MIB requirements. =back =head1 GLOBALS These are methods that return scalar value from SNMP =over =item $foundry->model() Returns model type. Checks $foundry->id() against the F and removes 'C'. EdgeIron models determined through F. =item $foundry->vendor() Returns 'brocade' =item $foundry->os() Returns 'brocade' =item $foundry->os_ver() Returns the software version =item $foundry->mac() Returns MAC Address of root port. (C) =item $foundry->chassis() Returns Chassis type. (C) =item $foundry->serial() Returns serial number of device. =item $foundry->temp() Returns the chassis temperature (C) =item $foundry->ps1_type() Returns the Description for the power supply (C) =item $foundry->ps1_status() Returns the status of the power supply. (C) =item $foundry->fan() Returns the status of the chassis fan. (C) =item $foundry->img_ver() Returns device image version. (C) =item $foundry->ch_serial() Returns chassis serial number. (C) =back =head2 Global Methods imported from SNMP::Info::Layer3 See documentation in L for details. =head2 Global Methods imported from SNMP::Info::FDP See documentation in L for details. =head2 Global Methods imported from SNMP::Info::LLDP See documentation in L for details. =head1 TABLE METHODS These are methods that return tables of information in the form of a reference to a hash. =head2 Overrides =over =item $foundry->interfaces() Returns reference to hash of interface names to iids. =item $foundry->i_ignore() Returns reference to hash of interfaces to be ignored. Ignores interfaces with descriptions of tunnel,loopback,null =item $foundry->i_duplex() Returns reference to hash of interface link duplex status. Crosses $foundry->sw_duplex() with $foundry->sw_index() =item $foundry->stp_p_state() "The port's current state as defined by application of the Spanning Tree Protocol. Skipped if device is an EdgeIron 24G due to reports of hangs. (C) =back =head2 Foundry Switch Port Information Table (C) =over =item $foundry->sw_index() Returns reference to hash. Maps Table to Interface IID. (C) =item $foundry->sw_duplex() Returns reference to hash. Current duplex status for switch ports. (C) =item $foundry->sw_type() Returns reference to hash. Current Port Type . (C) =item $foundry->sw_speed() Returns reference to hash. Current Port Speed. (C) =back =head2 Table Methods imported from SNMP::Info::Layer3 See documentation in L for details. =head2 Table Methods imported from SNMP::Info::FDP See documentation in L for details. =head2 Table Methods imported from SNMP::Info::LLDP See documentation in L for details. =cut