524 lines
		
	
	
		
			13 KiB
		
	
	
	
		
			Perl
		
	
	
	
	
	
			
		
		
	
	
			524 lines
		
	
	
		
			13 KiB
		
	
	
	
		
			Perl
		
	
	
	
	
	
| # SNMP::Info::Layer3::Dell - SNMP Interface to Dell devices
 | |
| #
 | |
| # Copyright (c) 2008 Eric Miller
 | |
| # All rights reserved.
 | |
| #
 | |
| # Redistribution and use in source and binary forms, with or without
 | |
| # modification, are permitted provided that the following conditions are met:
 | |
| #
 | |
| #     * Redistributions of source code must retain the above copyright notice,
 | |
| #       this list of conditions and the following disclaimer.
 | |
| #     * Redistributions in binary form must reproduce the above copyright
 | |
| #       notice, this list of conditions and the following disclaimer in the
 | |
| #       documentation and/or other materials provided with the distribution.
 | |
| #     * Neither the name of the University of California, Santa Cruz nor the
 | |
| #       names of its contributors may be used to endorse or promote products
 | |
| #       derived from this software without specific prior written permission.
 | |
| #
 | |
| # THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
 | |
| # AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
 | |
| # IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
 | |
| # ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE
 | |
| # LIABLE FOR # ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
 | |
| # CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
 | |
| # SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
 | |
| # INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
 | |
| # CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
 | |
| # ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
 | |
| # POSSIBILITY OF SUCH DAMAGE.
 | |
| 
 | |
| package SNMP::Info::Layer3::Dell;
 | |
| 
 | |
| use strict;
 | |
| use warnings;
 | |
| use Exporter;
 | |
| use SNMP::Info::Layer3;
 | |
| 
 | |
| @SNMP::Info::Layer3::Dell::ISA       = qw/SNMP::Info::Layer3 Exporter/;
 | |
| @SNMP::Info::Layer3::Dell::EXPORT_OK = qw//;
 | |
| 
 | |
| our ($VERSION, %GLOBALS, %FUNCS, %MIBS, %MUNGE);
 | |
| 
 | |
| $VERSION = '3.70';
 | |
| 
 | |
| %MIBS = (
 | |
|     %SNMP::Info::Layer3::MIBS,
 | |
|     'RADLAN-COPY-MIB'                => 'rlCopySourceLocation',
 | |
|     'RADLAN-Physicaldescription-MIB' => 'rlPhdStackReorder',
 | |
|     'RADLAN-rlInterfaces'            => 'rlIfNumOfLoopbackPorts',
 | |
|     'RADLAN-HWENVIROMENT'            => 'rlEnvPhysicalDescription',
 | |
|     'Dell-Vendor-MIB'                => 'productIdentificationVersion',
 | |
|     'DELL-REF-MIB'                   => 'dell6224Switch',
 | |
| );
 | |
| 
 | |
| %GLOBALS = (
 | |
|     %SNMP::Info::Layer3::GLOBALS,
 | |
|     'dell_os_ver'  => 'productIdentificationVersion',
 | |
|     'dell_id_name' => 'productIdentificationDisplayName',
 | |
| );
 | |
| 
 | |
| %FUNCS = (
 | |
|     %SNMP::Info::Layer3::FUNCS,
 | |
| 
 | |
|     # RADLAN-rlInterfaces:swIfTable
 | |
|     'dell_duplex_admin' => 'swIfDuplexAdminMode',
 | |
|     'dell_duplex'       => 'swIfDuplexOperMode',
 | |
|     'dell_tag_mode'     => 'swIfTaggedMode',
 | |
|     'dell_i_type'       => 'swIfType',
 | |
|     'dell_fc_admin'     => 'swIfFlowControlMode',
 | |
|     'dell_speed_admin'  => 'swIfSpeedAdminMode',
 | |
|     'dell_auto'         => 'swIfSpeedDuplexAutoNegotiation',
 | |
|     'dell_fc'           => 'swIfOperFlowControlMode',
 | |
| 
 | |
|     # RADLAN-Physicaldescription-MIB:rlPhdUnitGenParamTable
 | |
|     'dell_unit'      => 'rlPhdUnitGenParamStackUnit',
 | |
|     'dell_sw_ver'    => 'rlPhdUnitGenParamSoftwareVersion',
 | |
|     'dell_fw_ver'    => 'rlPhdUnitGenParamFirmwareVersion',
 | |
|     'dell_hw_ver'    => 'rlPhdUnitGenParamHardwareVersion',
 | |
|     'dell_serial_no' => 'rlPhdUnitGenParamSerialNum',
 | |
|     'dell_asset_no'  => 'rlPhdUnitGenParamAssetTag',
 | |
| 
 | |
|     # RADLAN-COPY-MIB:rlCopyTable
 | |
|     'dell_cp_idx'     => 'rlCopyIndex',
 | |
|     'dell_cp_sloc'    => 'rlCopySourceLocation',
 | |
|     'dell_cp_sip'     => 'rlCopySourceIpAddress',
 | |
|     'dell_cp_sunit'   => 'rlCopySourceUnitNumber',
 | |
|     'dell_cp_sfile'   => 'rlCopySourceFileName',
 | |
|     'dell_cp_stype'   => 'rlCopySourceFileType',
 | |
|     'dell_cp_dloc'    => 'rlCopyDestinationLocation',
 | |
|     'dell_cp_dip'     => 'rlCopyDestinationIpAddress',
 | |
|     'dell_cp_dunit'   => 'rlCopyDestinationUnitNumber',
 | |
|     'dell_cp_dfile'   => 'rlCopyDestinationFileName',
 | |
|     'dell_cp_dtype'   => 'rlCopyDestinationFileType',
 | |
|     'dell_cp_state'   => 'rlCopyOperationState',
 | |
|     'dell_cp_bkgnd'   => 'rlCopyInBackground',
 | |
|     'dell_cp_rstatus' => 'rlCopyRowStatus',
 | |
| 
 | |
|     # RADLAN-HWENVIROMENT:rlEnvMonSupplyStatusTable
 | |
|     'dell_pwr_src'   => 'rlEnvMonSupplySource',
 | |
|     'dell_pwr_state' => 'rlEnvMonSupplyState',
 | |
|     'dell_pwr_desc'  => 'rlEnvMonSupplyStatusDescr',
 | |
| 
 | |
|     # RADLAN-HWENVIROMENT:rlEnvMonFanStatusTable
 | |
|     'dell_fan_state' => 'rlEnvMonFanState',
 | |
|     'dell_fan_desc'  => 'rlEnvMonFanStatusDescr',
 | |
| );
 | |
| 
 | |
| %MUNGE = ( %SNMP::Info::Layer3::MUNGE, );
 | |
| 
 | |
| # Method OverRides
 | |
| 
 | |
| sub model {
 | |
|     my $dell = shift;
 | |
| 
 | |
|     my $name  = $dell->dell_id_name();
 | |
|     my $id    = $dell->id();
 | |
| 
 | |
|     if ( defined $name and $name =~ m/(\d+)/ ) {
 | |
|         return $1;
 | |
|     }
 | |
| 
 | |
|     return unless defined $id;
 | |
| 
 | |
|     my $model = SNMP::translateObj($id);
 | |
| 
 | |
|     if (defined $model) {
 | |
|         $model =~ s/^dell//;
 | |
|         $model =~ s/Switch$//;
 | |
|         return $model;
 | |
|     }
 | |
|     return $id;
 | |
| }
 | |
| 
 | |
| sub vendor {
 | |
|     my $dell = shift;
 | |
| 
 | |
|     return $dell->_vendor();
 | |
| }
 | |
| 
 | |
| sub os {
 | |
|     my $dell = shift;
 | |
| 
 | |
|     return $dell->_vendor();
 | |
| }
 | |
| 
 | |
| sub os_ver {
 | |
|     my $dell = shift;
 | |
| 
 | |
|     my $entity_os = $dell->entity_derived_os_ver();
 | |
|     if ( defined $entity_os and $entity_os !~ /^\s*$/ ){
 | |
|         return $entity_os;
 | |
|     }
 | |
| 
 | |
|     my $dell_os  = $dell->dell_os_ver();
 | |
|     if ( defined $dell_os and $dell_os !~ /^\s*$/ ) {
 | |
|         return $dell_os;
 | |
|     }
 | |
|     return;
 | |
| }
 | |
| 
 | |
| # check all fans, and report overall status
 | |
| sub fan {
 | |
|     my $dell = shift;
 | |
| 
 | |
|     my $fan   = $dell->dell_fan_desc()  || {};
 | |
|     my $state = $dell->dell_fan_state() || {};
 | |
| 
 | |
|     if (scalar keys %$fan) {
 | |
|         my @messages = ();
 | |
| 
 | |
|         foreach my $k (keys %$fan) {
 | |
|             next if $state->{$k} and $state->{$k} eq 'normal';
 | |
|             push @messages, "$fan->{$k}: $state->{$k}";
 | |
|         }
 | |
| 
 | |
|         push @messages, ((scalar keys %$fan). " fans OK")
 | |
|             if scalar @messages == 0;
 | |
| 
 | |
|         return (join ", ", @messages);
 | |
|         }
 | |
|     return;
 | |
| }
 | |
| 
 | |
| sub ps1_type {
 | |
|     my $dell = shift;
 | |
| 
 | |
|     my $src  = $dell->dell_pwr_src()  || {};
 | |
| 
 | |
|     foreach my $k (sort keys %$src) {
 | |
|         next unless $src->{$k};
 | |
|         return $src->{$k};
 | |
|     }
 | |
|     return;
 | |
| }
 | |
| 
 | |
| sub ps2_type {
 | |
|     my $dell = shift;
 | |
| 
 | |
|     my $src  = $dell->dell_pwr_src()  || {};
 | |
| 
 | |
|     my $i = 0;
 | |
|     foreach my $k (sort keys %$src) {
 | |
|         $i++;
 | |
|         next unless $src->{$k} and $i == 2;
 | |
|         return $src->{$k};
 | |
|     }
 | |
|     return;
 | |
| }
 | |
| 
 | |
| sub ps1_status {
 | |
|     my $dell = shift;
 | |
| 
 | |
|     my $status  = $dell->dell_pwr_state()  || {};
 | |
| 
 | |
|     foreach my $k (sort keys %$status) {
 | |
|         next unless $status->{$k};
 | |
|         return $status->{$k};
 | |
|     }
 | |
|     return;
 | |
| }
 | |
| 
 | |
| sub ps2_status {
 | |
|     my $dell = shift;
 | |
| 
 | |
|     my $status  = $dell->dell_pwr_state()  || {};
 | |
| 
 | |
|     my $i = 0;
 | |
|     foreach my $k (sort keys %$status) {
 | |
|         $i++;
 | |
|         next unless $status->{$k} and $i == 2;
 | |
|         return $status->{$k};
 | |
|     }
 | |
|     return;
 | |
| }
 | |
| 
 | |
| sub interfaces {
 | |
|     my $dell    = shift;
 | |
|     my $partial = shift;
 | |
| 
 | |
|     my $i_descr = $dell->i_description($partial) || {};
 | |
|     my $i_name  = $dell->orig_i_name($partial)   || {};
 | |
| 
 | |
|     # Descriptions are all the same on some Dells, so use name instead if
 | |
|     # available
 | |
|     foreach my $iid ( keys %$i_name ) {
 | |
|         my $name = $i_name->{$iid};
 | |
|         next unless defined $name;
 | |
|         $i_descr->{$iid} = $name;
 | |
|     }
 | |
| 
 | |
|     return $i_descr;
 | |
| }
 | |
| 
 | |
| sub i_duplex {
 | |
|     my $dell    = shift;
 | |
|     my $partial = shift;
 | |
| 
 | |
|     my $dell_duplex = $dell->dell_duplex($partial) || {};
 | |
| 
 | |
|     my %i_duplex;
 | |
|     foreach my $if ( keys %$dell_duplex ) {
 | |
|         my $duplex = $dell_duplex->{$if};
 | |
|         next unless defined $duplex;
 | |
|         next if $duplex eq 'unknown';
 | |
| 
 | |
|         $i_duplex{$if} = $duplex;
 | |
|     }
 | |
|     return \%i_duplex;
 | |
| }
 | |
| 
 | |
| sub i_duplex_admin {
 | |
|     my $dell    = shift;
 | |
|     my $partial = shift;
 | |
| 
 | |
|     my $interfaces  = $dell->interfaces($partial)        || {};
 | |
|     my $dell_duplex = $dell->dell_duplex_admin($partial) || {};
 | |
|     my $dell_auto   = $dell->dell_auto($partial)         || {};
 | |
| 
 | |
|     my %i_duplex_admin;
 | |
|     foreach my $if ( keys %$interfaces ) {
 | |
|         my $duplex = $dell_duplex->{$if};
 | |
|         next unless defined $duplex;
 | |
|         my $auto = $dell_auto->{$if} || 'disabled';
 | |
| 
 | |
|         $duplex = 'half' if ( $duplex eq 'half' and $auto eq 'disabled' );
 | |
|         $duplex = 'full' if ( $duplex eq 'full' and $auto eq 'disabled' );
 | |
|         $duplex = 'auto' if $auto eq 'enabled';
 | |
|         $i_duplex_admin{$if} = $duplex;
 | |
|     }
 | |
|     return \%i_duplex_admin;
 | |
| }
 | |
| 
 | |
| sub _vendor {
 | |
|     my $dell = shift;
 | |
| 
 | |
|     my $id = $dell->id() || 'undef';
 | |
|     my %oidmap = (
 | |
|         2    => 'ibm',
 | |
|         674  => 'dell',
 | |
|         3955 => 'linksys',
 | |
|     );
 | |
|     $id = $1 if ( defined($id) && $id =~ /^\.1\.3\.6\.1\.4\.1\.(\d+)/ );
 | |
| 
 | |
|     if ( defined($id) and exists( $oidmap{$id} ) ) {
 | |
|         return $oidmap{$id};
 | |
|     }
 | |
|     else {
 | |
|         return $id;
 | |
|     }
 | |
| }
 | |
| 
 | |
| # dot1qTpFdbTable uses dot1qVlanIndex rather than dot1qFdbId as index,
 | |
| # so pretend we don't have the mapping
 | |
| sub qb_fdb_index {return}
 | |
| 
 | |
| 1;
 | |
| __END__
 | |
| 
 | |
| =head1 NAME
 | |
| 
 | |
| SNMP::Info::Layer3::Dell - SNMP Interface to Dell Power Connect Network
 | |
| Devices
 | |
| 
 | |
| =head1 AUTHOR
 | |
| 
 | |
| Eric Miller
 | |
| 
 | |
| =head1 SYNOPSIS
 | |
| 
 | |
|  # Let SNMP::Info determine the correct subclass for you.
 | |
|  my $dell = new SNMP::Info(
 | |
|                           AutoSpecify => 1,
 | |
|                           Debug       => 1,
 | |
|                           DestHost    => 'myswitch',
 | |
|                           Community   => 'public',
 | |
|                           Version     => 2
 | |
|                         )
 | |
|     or die "Can't connect to DestHost.\n";
 | |
| 
 | |
|  my $class = $dell->class();
 | |
| 
 | |
|  print "SNMP::Info determined this device to fall under subclass : $class\n";
 | |
| 
 | |
| =head1 DESCRIPTION
 | |
| 
 | |
| Provides abstraction to the configuration information obtainable from an
 | |
| Dell Power Connect device through SNMP.  D-Link and the IBM BladeCenter
 | |
| Gigabit Ethernet Switch Module also use this module based upon MIB support.
 | |
| 
 | |
| For speed or debugging purposes you can call the subclass directly, but not
 | |
| after determining a more specific class using the method above.
 | |
| 
 | |
| my $dell = new SNMP::Info::Layer3::Dell(...);
 | |
| 
 | |
| =head2 Inherited Classes
 | |
| 
 | |
| =over
 | |
| 
 | |
| =item SNMP::Info::Layer3
 | |
| 
 | |
| =back
 | |
| 
 | |
| =head2 Required MIBs
 | |
| 
 | |
| =over
 | |
| 
 | |
| =item F<DELL-REF-MIB>
 | |
| 
 | |
| =item F<Dell-Vendor-MIB>
 | |
| 
 | |
| =item F<RADLAN-COPY-MIB>
 | |
| 
 | |
| =item F<RADLAN-HWENVIROMENT>
 | |
| 
 | |
| =item F<RADLAN-Physicaldescription-MIB>
 | |
| 
 | |
| =item F<RADLAN-rlInterfaces>
 | |
| 
 | |
| =item Inherited Classes' MIBs
 | |
| 
 | |
| See classes listed above for their required MIBs.
 | |
| 
 | |
| =back
 | |
| 
 | |
| =head1 GLOBALS
 | |
| 
 | |
| These are methods that return scalar value from SNMP
 | |
| 
 | |
| =over
 | |
| 
 | |
| =item $dell->os_ver()
 | |
| 
 | |
| (C<productIdentificationVersion>)
 | |
| 
 | |
| =item $dell->dell_id_name()
 | |
| 
 | |
| (C<productIdentificationDisplayName>)
 | |
| 
 | |
| =item $dell->model()
 | |
| 
 | |
| Returns model type.  Returns numeric from
 | |
| (C<productIdentificationDisplayName>) if available, otherwise if returns
 | |
| description().
 | |
| 
 | |
| =item $dell->vendor()
 | |
| 
 | |
| Returns 'dell', 'dlink', or 'ibm' based upon the IANA enterprise number in
 | |
| id().  Defaults to 'dlink'.
 | |
| 
 | |
| =item $dell->os()
 | |
| 
 | |
| Returns 'dell', 'dlink', or 'ibm' based upon the IANA enterprise number in
 | |
| id().  Defaults to 'dlink'.
 | |
| 
 | |
| =item $dell->fan()
 | |
| 
 | |
| Return the status of all fans from the F<Dell-Vendor-MIB>
 | |
| 
 | |
| =item $dell->ps1_type()
 | |
| 
 | |
| Return the type of the first power supply from the F<Dell-Vendor-MIB>
 | |
| 
 | |
| =item $dell->ps2_type()
 | |
| 
 | |
| Return the type of the second power supply from the F<Dell-Vendor-MIB>
 | |
| 
 | |
| =item $dell->ps1_status()
 | |
| 
 | |
| Return the status of the first power supply from the F<Dell-Vendor-MIB>
 | |
| 
 | |
| =item $dell->ps2_status()
 | |
| 
 | |
| Return the status of the second power supply from the F<Dell-Vendor-MIB>
 | |
| 
 | |
| =back
 | |
| 
 | |
| =head2 Overrides
 | |
| 
 | |
| =over
 | |
| 
 | |
| =item $dell->serial()
 | |
| 
 | |
| Returns serial number. Returns (C<rlPhdUnitGenParamSerialNum>) if available,
 | |
| otherwise uses the Layer3 serial method.
 | |
| 
 | |
| =back
 | |
| 
 | |
| =head2 Globals imported from SNMP::Info::Layer3
 | |
| 
 | |
| See documentation in L<SNMP::Info::Layer3/"GLOBALS"> for details.
 | |
| 
 | |
| =head1 TABLE METHODS
 | |
| 
 | |
| These are methods that return tables of information in the form of a reference
 | |
| to a hash.
 | |
| 
 | |
| =head2 RADLAN Interface Table (C<swIfTable>)
 | |
| 
 | |
| =over
 | |
| 
 | |
| =item $dell->dell_duplex_admin()
 | |
| 
 | |
| (C<swIfDuplexAdminMode>)
 | |
| 
 | |
| =item $dell->dell_duplex()
 | |
| 
 | |
| (C<swIfDuplexOperMode>)
 | |
| 
 | |
| =item $dell->dell_tag_mode()
 | |
| 
 | |
| (C<swIfTaggedMode>)
 | |
| 
 | |
| =item $dell->dell_i_type()
 | |
| 
 | |
| (C<swIfType>)
 | |
| 
 | |
| =item $dell->dell_fc_admin()
 | |
| 
 | |
| (C<swIfFlowControlMode>)
 | |
| 
 | |
| =item $dell->dell_speed_admin()
 | |
| 
 | |
| (C<swIfSpeedAdminMode>)
 | |
| 
 | |
| =item $dell->dell_auto()
 | |
| 
 | |
| (C<swIfSpeedDuplexAutoNegotiation>)
 | |
| 
 | |
| =item $dell->dell_fc()
 | |
| 
 | |
| (C<swIfOperFlowControlMode>)
 | |
| 
 | |
| =back
 | |
| 
 | |
| =head2 Overrides
 | |
| 
 | |
| =over
 | |
| 
 | |
| =item $dell->interfaces()
 | |
| 
 | |
| Returns the map between SNMP Interface Identifier (iid) and physical port
 | |
| name.  Uses name if available instead of description since descriptions are
 | |
| sometimes not unique.
 | |
| 
 | |
| =item $dell->i_duplex()
 | |
| 
 | |
| Returns reference to map of IIDs to current link duplex.
 | |
| 
 | |
| =item $dell->i_duplex_admin()
 | |
| 
 | |
| Returns reference to hash of iid to current link administrative duplex
 | |
| setting.
 | |
| 
 | |
| =item $dell->qb_fdb_index()
 | |
| 
 | |
| Returns nothing to work around incorrect indexing of C<dot1qTpFdbTable>
 | |
| 
 | |
| =back
 | |
| 
 | |
| =head2 Table Methods imported from SNMP::Info::Layer3
 | |
| 
 | |
| See documentation in L<SNMP::Info::Layer3/"TABLE METHODS"> for details.
 | |
| 
 | |
| =cut
 |