313 lines
		
	
	
		
			7.7 KiB
		
	
	
	
		
			Perl
		
	
	
	
	
	
			
		
		
	
	
			313 lines
		
	
	
		
			7.7 KiB
		
	
	
	
		
			Perl
		
	
	
	
	
	
# SNMP::Info::Layer3::Scalance - SNMP Interface to Siemens Scalance
 | 
						|
#
 | 
						|
# Copyright (c) 2019 Christoph Handel GSI Helmholtzzentrum fuer
 | 
						|
# Schwerionenforschung
 | 
						|
#
 | 
						|
# Copyright (c) 2008-2009 Max Baker changes from version 0.8 and beyond.
 | 
						|
#
 | 
						|
# Copyright (c) 2002,2003 Regents of the University of California
 | 
						|
#
 | 
						|
# All rights reserved.
 | 
						|
#
 | 
						|
# Redistribution and use in source and binary forms, with or without
 | 
						|
# modification, are permitted provided that the following conditions are met:
 | 
						|
#
 | 
						|
#     * Redistributions of source code must retain the above copyright notice,
 | 
						|
#       this list of conditions and the following disclaimer.
 | 
						|
#     * Redistributions in binary form must reproduce the above copyright
 | 
						|
#       notice, this list of conditions and the following disclaimer in the
 | 
						|
#       documentation and/or other materials provided with the distribution.
 | 
						|
#     * Neither the name of the University of California, Santa Cruz , 
 | 
						|
#       the GSI Helmholtzzentrum fuer Schwerionenforschung, nor the
 | 
						|
#       names of its contributors may be used to endorse or promote products
 | 
						|
#       derived from this software without specific prior written permission
 | 
						|
#
 | 
						|
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
 | 
						|
# AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
 | 
						|
# IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
 | 
						|
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE
 | 
						|
# LIABLE FOR # ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
 | 
						|
# CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
 | 
						|
# SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
 | 
						|
# INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
 | 
						|
# CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
 | 
						|
# ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
 | 
						|
# POSSIBILITY OF SUCH DAMAGE.
 | 
						|
#
 | 
						|
 | 
						|
package SNMP::Info::Layer3::Scalance;
 | 
						|
 | 
						|
use strict;
 | 
						|
use warnings;
 | 
						|
use Exporter;
 | 
						|
use Socket;
 | 
						|
use SNMP::Info::Layer3;
 | 
						|
use SNMP::Info::MAU;
 | 
						|
 | 
						|
@SNMP::Info::Layer3::Scalance::ISA = qw/
 | 
						|
    SNMP::Info::Layer3
 | 
						|
    SNMP::Info::MAU
 | 
						|
    Exporter
 | 
						|
/;
 | 
						|
@SNMP::Info::Layer3::Scalance::EXPORT_OK = qw//;
 | 
						|
 | 
						|
our ($VERSION, %GLOBALS, %MIBS, %FUNCS, %PORTSTAT, %MODEL_MAP, %MUNGE);
 | 
						|
 | 
						|
$VERSION = '3.71';
 | 
						|
 | 
						|
%MIBS = (
 | 
						|
    %SNMP::Info::Layer3::MIBS,
 | 
						|
    %SNMP::Info::MAU::MIBS,
 | 
						|
    'SN-MSPS-SCX-MIB' => 'snMsps',
 | 
						|
    'AUTOMATION-SYSTEM-MIB' => 'automationManufacturerId',
 | 
						|
);
 | 
						|
 | 
						|
%GLOBALS = (
 | 
						|
    %SNMP::Info::Layer3::GLOBALS,
 | 
						|
    %SNMP::Info::MAU::GLOBALS,
 | 
						|
    'serial1'      => 'automationSerialNumber.0',
 | 
						|
    'ps1_status' => 'snMspsPowerSupply1State.0',
 | 
						|
    'ps2_status' => 'snMspsPowerSupply2State.0',
 | 
						|
    'os_ver'   => 'automationSwRevision.0',
 | 
						|
);
 | 
						|
 | 
						|
%FUNCS = (
 | 
						|
    %SNMP::Info::Layer3::FUNCS,
 | 
						|
    %SNMP::Info::MAU::FUNCS,
 | 
						|
);
 | 
						|
 | 
						|
%MUNGE = (
 | 
						|
    # Inherit all the built in munging
 | 
						|
    %SNMP::Info::Layer3::MUNGE,
 | 
						|
    %SNMP::Info::MAU::MUNGE,
 | 
						|
);
 | 
						|
 | 
						|
sub layers {
 | 
						|
    # at least x500 reports value 72, which is layer 4+7
 | 
						|
    # but it sure is a bridge and can do 2 and 3
 | 
						|
    return '00000111';
 | 
						|
}
 | 
						|
 | 
						|
sub os {
 | 
						|
    return 'scalance';
 | 
						|
}
 | 
						|
 | 
						|
sub vendor {
 | 
						|
    return 'siemens';
 | 
						|
}
 | 
						|
 | 
						|
sub model {
 | 
						|
    my $scalance = shift;
 | 
						|
    # object id is only the general class (x500, x400, etc)
 | 
						|
    # extract something meaningful from the description
 | 
						|
    # my $id = $scalance->id();
 | 
						|
    my $description = $scalance->description();
 | 
						|
    # Siemens, SIMATIC NET, SCALANCE XR524-8C 2PS, 6GK5 524-8GS00-4AR2, HW: Version 1,...
 | 
						|
    $description =~ s/.*?(SCALANCE .*?),.*/$1/;
 | 
						|
    return $description;
 | 
						|
}
 | 
						|
 | 
						|
sub mac {
 | 
						|
    # use dot1dBaseBridgeAddress
 | 
						|
    my $scalance = shift;
 | 
						|
    return $scalance->b_mac();
 | 
						|
}
 | 
						|
 | 
						|
sub os_ver {
 | 
						|
    # clean up os_ver string
 | 
						|
    my $scalance = shift;
 | 
						|
    my $result = $scalance->SUPER::os_ver();
 | 
						|
    $result =~ s/^V//;
 | 
						|
    return $result;
 | 
						|
}
 | 
						|
 | 
						|
sub i_description {
 | 
						|
    # munge interface descriptions, from
 | 
						|
    #
 | 
						|
    # Siemens, SIMATIC NET, SCALANCE XR524-8C 2PS, 6GK5 524-8GS00-4AR2, 
 | 
						|
    #    HW: Version 1, FW: Version V06.02.02, SERIAL, Ethernet Port, R0/S0/X1 P16
 | 
						|
    #
 | 
						|
    # to
 | 
						|
    #
 | 
						|
    # R0/S0/X1 P16
 | 
						|
 | 
						|
    my $scalance = shift;
 | 
						|
 | 
						|
    my $orig = $scalance->SUPER::i_description();
 | 
						|
    my %result;
 | 
						|
    foreach my $iid ( keys %$orig ) {
 | 
						|
        my $descr = $orig->{$iid};
 | 
						|
        my $short;
 | 
						|
        ($short) = $descr =~ /.*(?:Port, |VLAN, )(.*)$/;
 | 
						|
        if ( ! $short ) {
 | 
						|
            # splitting at VLAN/PORT failed, just the part after the last comma
 | 
						|
            ($short) = $descr =~ /.*, (.*)$/;
 | 
						|
        }
 | 
						|
        $result{$iid} = $short;
 | 
						|
    }
 | 
						|
    return \%result;
 | 
						|
}
 | 
						|
 | 
						|
sub lldp_ip {
 | 
						|
    my $scalance = shift;
 | 
						|
    my %result;
 | 
						|
    my $remotes = $scalance->lldp_rem_sysname();
 | 
						|
    foreach my $port ( keys %$remotes) {
 | 
						|
	my $ip = gethostbyname($remotes->{$port});
 | 
						|
	if ($ip) {
 | 
						|
	    $result{$port} = inet_ntoa($ip);
 | 
						|
	}
 | 
						|
    }
 | 
						|
    return \%result
 | 
						|
};
 | 
						|
 | 
						|
 | 
						|
1;
 | 
						|
__END__
 | 
						|
 | 
						|
=head1 NAME
 | 
						|
 | 
						|
SNMP::Info::Layer3::Scalance - SNMP Interface to Siemens Scalance Switches
 | 
						|
 | 
						|
=head1 AUTHOR
 | 
						|
 | 
						|
Christoph Handel
 | 
						|
 | 
						|
=head1 SYNOPSIS
 | 
						|
 | 
						|
 # Let SNMP::Info determine the correct subclass for you.
 | 
						|
 my $scalance = new SNMP::Info(
 | 
						|
                          AutoSpecify => 1,
 | 
						|
                          Debug       => 1,
 | 
						|
                          DestHost    => 'myswitch',
 | 
						|
                          Community   => 'public',
 | 
						|
                          Version     => 2
 | 
						|
                        )
 | 
						|
    or die "Can't connect to DestHost.\n";
 | 
						|
 | 
						|
 my $class      = $scalance->class();
 | 
						|
 print "SNMP::Info determined this device to fall under subclass : $class\n";
 | 
						|
 | 
						|
=head1 DESCRIPTION
 | 
						|
 | 
						|
Provides abstraction to the configuration information obtainable from a
 | 
						|
Siemens Scalance Switch via SNMP.
 | 
						|
 | 
						|
Tested only with scalance xr524
 | 
						|
 | 
						|
=head2 Inherited Classes
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=item SNMP::Info::Layer3
 | 
						|
 | 
						|
=item SNMP::Info::MAU
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head2 Required MIBs
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=item F<AUTOMATION-SMI>
 | 
						|
 | 
						|
=item F<AUTOMATION-SYSTEM-MIB>
 | 
						|
 | 
						|
=item F<AUTOMATION-TC>
 | 
						|
 | 
						|
=item F<SIEMENS-SMI>
 | 
						|
 | 
						|
=item F<SN-MSPS-SCX-MIB>
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
L<https://support.industry.siemens.com/cs/document/22015045/private-mibs%3A-scalance-x-scalance-w-and-snmp-opc-profile?dti=0&lc=en-DE>
 | 
						|
 | 
						|
L<https://support.industry.siemens.com/cs/document/67637278/automationmib-now-available-for-download-in-version-v02-00-00-02-?dti=0&lc=en-TN>
 | 
						|
 | 
						|
 | 
						|
=head1 Change Log
 | 
						|
 | 
						|
=head1 GLOBALS
 | 
						|
 | 
						|
These are methods that return scalar value from SNMP
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=item $scalance->layers()
 | 
						|
 | 
						|
Overwrite snmp value, we support 1-3
 | 
						|
 | 
						|
=item $scalance->os()
 | 
						|
 | 
						|
Returns scalance
 | 
						|
 | 
						|
=item $scalance->vendor()
 | 
						|
 | 
						|
Returns siemens
 | 
						|
 | 
						|
=item $scalance->model()
 | 
						|
 | 
						|
extract a meaningful name from description
 | 
						|
 | 
						|
=item $scalance->mac()
 | 
						|
 | 
						|
use the dot1dBaseBridgeAddress
 | 
						|
 | 
						|
=item $scalance->os_ver()
 | 
						|
 | 
						|
clean up os_version string
 | 
						|
 | 
						|
=item $scalance->i_description()
 | 
						|
 | 
						|
siemens returns a description including firmware, switch serial, etc
 | 
						|
clean it up. Try to use anything past VLAN or Port. And if this fails 
 | 
						|
past the last comma
 | 
						|
 | 
						|
=item $scalance->lldp_ip()
 | 
						|
 | 
						|
simatic does not implement lldpRemManAddrIfSubtype
 | 
						|
but remote system names are available
 | 
						|
try to resolve them via DNS and use that
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head2 Globals imported from SNMP::Info::Layer3
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::Layer3/"GLOBALS"> for details.
 | 
						|
 | 
						|
=head2 Globals imported from SNMP::Info::MAU
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::MAU/"GLOBALS"> for details.
 | 
						|
 | 
						|
=head1 TABLE METHODS
 | 
						|
 | 
						|
These are methods that return tables of information in the form of a reference
 | 
						|
to a hash.
 | 
						|
 | 
						|
=head2 Overrides
 | 
						|
 | 
						|
=over 4
 | 
						|
 | 
						|
=item $scalance->lldp_ip()
 | 
						|
 | 
						|
Returns reference to hash of ports to remote ips.
 | 
						|
 | 
						|
simatic does not implement lldpRemManAddrIfSubtype
 | 
						|
but remote system names are available
 | 
						|
try to resolve them via DNS and use that.
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head2 Table Methods imported from SNMP::Info::Layer3
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::Layer3/"TABLE METHODS"> for details.
 | 
						|
 | 
						|
=head2 Table Methods imported from SNMP::Info::MAU
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::MAU/"TABLE METHODS"> for details.
 | 
						|
 | 
						|
=cut
 | 
						|
 | 
						|
# vim: filetype=perl ts=4 sw=4 sta et sts=4 ai
 |