# SNMP::Info::Layer3::Extreme - SNMP Interface to Extreme devices
 | 
						|
# Eric Miller
 | 
						|
#
 | 
						|
# Copyright (c) 2005 Eric Miller
 | 
						|
#
 | 
						|
# Copyright (c) 2002,2003 Regents of the University of California
 | 
						|
# All rights reserved.
 | 
						|
# 
 | 
						|
# Redistribution and use in source and binary forms, with or without 
 | 
						|
# modification, are permitted provided that the following conditions are met:
 | 
						|
# 
 | 
						|
#     * Redistributions of source code must retain the above copyright notice,
 | 
						|
#       this list of conditions and the following disclaimer.
 | 
						|
#     * Redistributions in binary form must reproduce the above copyright notice,
 | 
						|
#       this list of conditions and the following disclaimer in the documentation
 | 
						|
#       and/or other materials provided with the distribution.
 | 
						|
#     * Neither the name of the University of California, Santa Cruz nor the 
 | 
						|
#       names of its contributors may be used to endorse or promote products 
 | 
						|
#       derived from this software without specific prior written permission.
 | 
						|
# 
 | 
						|
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND
 | 
						|
# ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED 
 | 
						|
# WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE 
 | 
						|
# DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR
 | 
						|
# ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
 | 
						|
# (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; 
 | 
						|
# LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON
 | 
						|
# ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT 
 | 
						|
# (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS 
 | 
						|
# SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
 | 
						|
 | 
						|
package SNMP::Info::Layer3::Extreme;
 | 
						|
# $Id$
 | 
						|
 | 
						|
use strict;
 | 
						|
 | 
						|
use Exporter;
 | 
						|
use SNMP::Info::Layer3;
 | 
						|
use SNMP::Info::MAU;
 | 
						|
 | 
						|
use vars qw/$VERSION $DEBUG %GLOBALS %FUNCS $INIT %MIBS %MUNGE/;
 | 
						|
 | 
						|
$VERSION = '1.04';
 | 
						|
 | 
						|
@SNMP::Info::Layer3::Extreme::ISA = qw/SNMP::Info::Layer3 SNMP::Info::MAU Exporter/;
 | 
						|
@SNMP::Info::Layer3::Extreme::EXPORT_OK = qw//;
 | 
						|
 | 
						|
%MIBS = ( %SNMP::Info::Layer3::MIBS,
 | 
						|
          %SNMP::Info::MAU::MIBS,
 | 
						|
          'EXTREME-BASE-MIB'   => 'extremeAgent',
 | 
						|
          'EXTREME-SYSTEM-MIB' => 'extremeSystem',
 | 
						|
          'EXTREME-FDB-MIB'    => 'extremeSystem',
 | 
						|
        );
 | 
						|
 | 
						|
%GLOBALS = (
 | 
						|
            %SNMP::Info::Layer3::GLOBALS,
 | 
						|
            %SNMP::Info::MAU::GLOBALS,
 | 
						|
            'serial'     => 'extremeSystemID',
 | 
						|
            'temp'       => 'extremeCurrentTemperature',
 | 
						|
            'ps1_status' => 'extremePowerSupplyStatus.1',
 | 
						|
            'fan'        => 'extremeFanOperational.1',
 | 
						|
            'mac'        => 'dot1dBaseBridgeAddress',
 | 
						|
           );
 | 
						|
 | 
						|
%FUNCS   = (
 | 
						|
            %SNMP::Info::Layer3::FUNCS,
 | 
						|
            %SNMP::Info::MAU::FUNCS,
 | 
						|
            # EXTREME-FDB-MIB:extremeFdbMacFdbTable
 | 
						|
            'fw_mac'     => 'extremeFdbMacFdbMacAddress',
 | 
						|
            'fw_port'    => 'extremeFdbMacFdbPortIfIndex',
 | 
						|
            'fw_status'  => 'extremeFdbMacFdbStatus',
 | 
						|
           );
 | 
						|
 | 
						|
%MUNGE = (
 | 
						|
            # Inherit all the built in munging
 | 
						|
            %SNMP::Info::Layer3::MUNGE,
 | 
						|
            %SNMP::Info::MAU::MUNGE,
 | 
						|
         );
 | 
						|
 | 
						|
# Method OverRides
 | 
						|
 | 
						|
sub bulkwalk_no { 1; }
 | 
						|
 | 
						|
*SNMP::Info::Layer3::Extreme::i_duplex       = \&SNMP::Info::MAU::mau_i_duplex;
 | 
						|
*SNMP::Info::Layer3::Extreme::i_duplex_admin = \&SNMP::Info::MAU::mau_i_duplex_admin;
 | 
						|
 | 
						|
sub model {
 | 
						|
    my $extreme = shift;
 | 
						|
    my $id = $extreme->id();
 | 
						|
    
 | 
						|
    unless (defined $id){
 | 
						|
        print " SNMP::Info::Layer3::Extreme::model() - Device does not support sysObjectID\n" if $extreme->debug(); 
 | 
						|
        return undef;
 | 
						|
    }
 | 
						|
    
 | 
						|
    my $model = &SNMP::translateObj($id);
 | 
						|
 | 
						|
    return $id unless defined $model;
 | 
						|
 | 
						|
    return $model;
 | 
						|
}
 | 
						|
 | 
						|
sub vendor {
 | 
						|
    return 'extreme';
 | 
						|
}
 | 
						|
 | 
						|
sub os {
 | 
						|
    return 'extreme';
 | 
						|
}
 | 
						|
 | 
						|
sub os_ver {
 | 
						|
    my $extreme = shift;
 | 
						|
    my $descr = $extreme->description();
 | 
						|
    return undef unless defined $descr;
 | 
						|
 | 
						|
    if ($descr =~ m/Version ([\d.]*)/){
 | 
						|
        return $1;
 | 
						|
    }
 | 
						|
 | 
						|
    return undef;
 | 
						|
}
 | 
						|
 | 
						|
# We're not using BRIDGE-MIB
 | 
						|
sub bp_index {
 | 
						|
    my $extreme = shift;
 | 
						|
    my $if_index = $extreme->i_index();
 | 
						|
 | 
						|
    my %bp_index;
 | 
						|
    foreach my $iid (keys %$if_index){
 | 
						|
        $bp_index{$iid} = $iid;
 | 
						|
    }
 | 
						|
    return \%bp_index;
 | 
						|
}
 | 
						|
 | 
						|
# Index values in the Q-BRIDGE-MIB are the same
 | 
						|
# as in the BRIDGE-MIB and do not match ifIndex.
 | 
						|
sub i_vlan {
 | 
						|
    my $extreme = shift;
 | 
						|
    my $qb_i_vlan = $extreme->qb_i_vlan();
 | 
						|
    my $bp_index = $extreme->bp_index();
 | 
						|
 | 
						|
    my %i_vlan;
 | 
						|
    foreach my $v_index (keys %$qb_i_vlan){
 | 
						|
        my $vlan = $qb_i_vlan->{$v_index};
 | 
						|
        my $iid  = $bp_index->{$v_index};
 | 
						|
 | 
						|
        unless (defined $iid) {
 | 
						|
            print "  Port $v_index has no bp_index mapping. Skipping\n"
 | 
						|
                if $DEBUG;
 | 
						|
            next;
 | 
						|
        }
 | 
						|
        $i_vlan{$iid}=$vlan; 
 | 
						|
    }
 | 
						|
    return \%i_vlan;
 | 
						|
}
 | 
						|
 | 
						|
1;
 | 
						|
__END__
 | 
						|
 | 
						|
=head1 NAME
 | 
						|
 | 
						|
SNMP::Info::Layer3::Extreme - Perl5 Interface to Extreme Network Devices
 | 
						|
 | 
						|
=head1 AUTHOR
 | 
						|
 | 
						|
Eric Miller
 | 
						|
 | 
						|
=head1 SYNOPSIS
 | 
						|
 | 
						|
 # Let SNMP::Info determine the correct subclass for you. 
 | 
						|
 my $extreme = new SNMP::Info(
 | 
						|
                          AutoSpecify => 1,
 | 
						|
                          Debug       => 1,
 | 
						|
                          # These arguments are passed directly on to SNMP::Session
 | 
						|
                          DestHost    => 'myswitch',
 | 
						|
                          Community   => 'public',
 | 
						|
                          Version     => 1
 | 
						|
                        ) 
 | 
						|
    or die "Can't connect to DestHost.\n";
 | 
						|
 | 
						|
 my $class      = $extreme->class();
 | 
						|
 | 
						|
 print "SNMP::Info determined this device to fall under subclass : $class\n";
 | 
						|
 | 
						|
=head1 DESCRIPTION
 | 
						|
 | 
						|
Provides abstraction to the configuration information obtainable from an 
 | 
						|
Extreme device through SNMP. 
 | 
						|
 | 
						|
For speed or debugging purposes you can call the subclass directly, but not after determining
 | 
						|
a more specific class using the method above. 
 | 
						|
 | 
						|
my $extreme = new SNMP::Info::Layer3::Extreme(...);
 | 
						|
 | 
						|
=head2 Inherited Classes
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=item SNMP::Info::Layer3
 | 
						|
 | 
						|
=item SNMP::Info::MAU
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head2 Required MIBs
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=item EXTREME-BASE-MIB
 | 
						|
 | 
						|
=item EXTREME-SYSTEM-MIB
 | 
						|
 | 
						|
=item EXTREME-FDB-MIB
 | 
						|
 | 
						|
=item Inherited Classes' MIBs
 | 
						|
 | 
						|
See classes listed above for their required MIBs.
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head1 GLOBALS
 | 
						|
 | 
						|
These are methods that return scalar value from SNMP
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=item $extreme->bulkwalk_no
 | 
						|
 | 
						|
Return C<1>.  Bulkwalk is currently turned off for this class.
 | 
						|
 | 
						|
=item $extreme->model()
 | 
						|
 | 
						|
Returns model type.  Checks $extreme->id() against the EXTREME-BASE-MIB.
 | 
						|
 | 
						|
=item $extreme->vendor()
 | 
						|
 | 
						|
Returns extreme
 | 
						|
 | 
						|
=item $extreme->os()
 | 
						|
 | 
						|
Returns extreme
 | 
						|
 | 
						|
=item $extreme->serial()
 | 
						|
 | 
						|
Returns serial number
 | 
						|
 | 
						|
(B<extremeSystemID>)
 | 
						|
 | 
						|
=item $extreme->temp()
 | 
						|
 | 
						|
Returns system temperature
 | 
						|
 | 
						|
(B<extremeCurrentTemperature>)
 | 
						|
 | 
						|
=item $extreme->ps1_status()
 | 
						|
 | 
						|
Returns status of power supply 1
 | 
						|
 | 
						|
(B<extremePowerSupplyStatus.1>)
 | 
						|
 | 
						|
=item $extreme->fan()
 | 
						|
 | 
						|
Returns fan status
 | 
						|
 | 
						|
(B<extremeFanOperational.1>)
 | 
						|
 | 
						|
=item $extreme->mac()
 | 
						|
 | 
						|
Returns base mac
 | 
						|
 | 
						|
(B<dot1dBaseBridgeAddress>)
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head2 Overrides
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head2 Globals imported from SNMP::Info::Layer3
 | 
						|
 | 
						|
See documentation in SNMP::Info::Layer3 for details.
 | 
						|
 | 
						|
=head2 Globals imported from SNMP::Info::MAU
 | 
						|
 | 
						|
See documentation in SNMP::Info::MAU for details.
 | 
						|
 | 
						|
=head1 TABLE ENTRIES
 | 
						|
 | 
						|
These are methods that return tables of information in the form of a reference
 | 
						|
to a hash.
 | 
						|
 | 
						|
=head2 Overrides
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=item $extreme->fw_mac()
 | 
						|
 | 
						|
(B<extremeFdbMacFdbMacAddress>)
 | 
						|
 | 
						|
=item $extreme->fw_port()
 | 
						|
 | 
						|
(B<extremeFdbMacFdbPortIfIndex>)
 | 
						|
 | 
						|
=item $extreme->fw_status()
 | 
						|
 | 
						|
(B<extremeFdbMacFdbStatus>)
 | 
						|
 | 
						|
=item $extreme->i_vlan()
 | 
						|
 | 
						|
Returns a mapping between ifIndex and the VLAN.
 | 
						|
 | 
						|
=item $stack->bp_index()
 | 
						|
 | 
						|
Returns reference to hash of bridge port table entries map back to interface identifier (iid)
 | 
						|
 | 
						|
Returns (B<ifIndex>) for both key and value since we're using EXTREME-FDB-MIB
 | 
						|
rather than BRIDGE-MIB.
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head2 Table Methods imported from SNMP::Info::Layer3
 | 
						|
 | 
						|
See documentation in SNMP::Info::Layer3 for details.
 | 
						|
 | 
						|
=head2 Table Methods imported from SNMP::Info::MAU
 | 
						|
 | 
						|
See documentation in SNMP::Info::MAU for details.
 | 
						|
 | 
						|
=cut
 |