524 lines
13 KiB
Perl
524 lines
13 KiB
Perl
# SNMP::Info::Layer3::Dell - SNMP Interface to Dell devices
|
|
#
|
|
# Copyright (c) 2008 Eric Miller
|
|
# All rights reserved.
|
|
#
|
|
# Redistribution and use in source and binary forms, with or without
|
|
# modification, are permitted provided that the following conditions are met:
|
|
#
|
|
# * Redistributions of source code must retain the above copyright notice,
|
|
# this list of conditions and the following disclaimer.
|
|
# * Redistributions in binary form must reproduce the above copyright
|
|
# notice, this list of conditions and the following disclaimer in the
|
|
# documentation and/or other materials provided with the distribution.
|
|
# * Neither the name of the University of California, Santa Cruz nor the
|
|
# names of its contributors may be used to endorse or promote products
|
|
# derived from this software without specific prior written permission.
|
|
#
|
|
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
|
|
# AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
|
# IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
|
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE
|
|
# LIABLE FOR # ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
|
|
# CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
|
|
# SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
|
|
# INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
|
|
# CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
|
|
# ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
|
|
# POSSIBILITY OF SUCH DAMAGE.
|
|
|
|
package SNMP::Info::Layer3::Dell;
|
|
|
|
use strict;
|
|
use warnings;
|
|
use Exporter;
|
|
use SNMP::Info::Layer3;
|
|
|
|
@SNMP::Info::Layer3::Dell::ISA = qw/SNMP::Info::Layer3 Exporter/;
|
|
@SNMP::Info::Layer3::Dell::EXPORT_OK = qw//;
|
|
|
|
our ($VERSION, %GLOBALS, %FUNCS, %MIBS, %MUNGE);
|
|
|
|
$VERSION = '3.70';
|
|
|
|
%MIBS = (
|
|
%SNMP::Info::Layer3::MIBS,
|
|
'RADLAN-COPY-MIB' => 'rlCopySourceLocation',
|
|
'RADLAN-Physicaldescription-MIB' => 'rlPhdStackReorder',
|
|
'RADLAN-rlInterfaces' => 'rlIfNumOfLoopbackPorts',
|
|
'RADLAN-HWENVIROMENT' => 'rlEnvPhysicalDescription',
|
|
'Dell-Vendor-MIB' => 'productIdentificationVersion',
|
|
'DELL-REF-MIB' => 'dell6224Switch',
|
|
);
|
|
|
|
%GLOBALS = (
|
|
%SNMP::Info::Layer3::GLOBALS,
|
|
'dell_os_ver' => 'productIdentificationVersion',
|
|
'dell_id_name' => 'productIdentificationDisplayName',
|
|
);
|
|
|
|
%FUNCS = (
|
|
%SNMP::Info::Layer3::FUNCS,
|
|
|
|
# RADLAN-rlInterfaces:swIfTable
|
|
'dell_duplex_admin' => 'swIfDuplexAdminMode',
|
|
'dell_duplex' => 'swIfDuplexOperMode',
|
|
'dell_tag_mode' => 'swIfTaggedMode',
|
|
'dell_i_type' => 'swIfType',
|
|
'dell_fc_admin' => 'swIfFlowControlMode',
|
|
'dell_speed_admin' => 'swIfSpeedAdminMode',
|
|
'dell_auto' => 'swIfSpeedDuplexAutoNegotiation',
|
|
'dell_fc' => 'swIfOperFlowControlMode',
|
|
|
|
# RADLAN-Physicaldescription-MIB:rlPhdUnitGenParamTable
|
|
'dell_unit' => 'rlPhdUnitGenParamStackUnit',
|
|
'dell_sw_ver' => 'rlPhdUnitGenParamSoftwareVersion',
|
|
'dell_fw_ver' => 'rlPhdUnitGenParamFirmwareVersion',
|
|
'dell_hw_ver' => 'rlPhdUnitGenParamHardwareVersion',
|
|
'dell_serial_no' => 'rlPhdUnitGenParamSerialNum',
|
|
'dell_asset_no' => 'rlPhdUnitGenParamAssetTag',
|
|
|
|
# RADLAN-COPY-MIB:rlCopyTable
|
|
'dell_cp_idx' => 'rlCopyIndex',
|
|
'dell_cp_sloc' => 'rlCopySourceLocation',
|
|
'dell_cp_sip' => 'rlCopySourceIpAddress',
|
|
'dell_cp_sunit' => 'rlCopySourceUnitNumber',
|
|
'dell_cp_sfile' => 'rlCopySourceFileName',
|
|
'dell_cp_stype' => 'rlCopySourceFileType',
|
|
'dell_cp_dloc' => 'rlCopyDestinationLocation',
|
|
'dell_cp_dip' => 'rlCopyDestinationIpAddress',
|
|
'dell_cp_dunit' => 'rlCopyDestinationUnitNumber',
|
|
'dell_cp_dfile' => 'rlCopyDestinationFileName',
|
|
'dell_cp_dtype' => 'rlCopyDestinationFileType',
|
|
'dell_cp_state' => 'rlCopyOperationState',
|
|
'dell_cp_bkgnd' => 'rlCopyInBackground',
|
|
'dell_cp_rstatus' => 'rlCopyRowStatus',
|
|
|
|
# RADLAN-HWENVIROMENT:rlEnvMonSupplyStatusTable
|
|
'dell_pwr_src' => 'rlEnvMonSupplySource',
|
|
'dell_pwr_state' => 'rlEnvMonSupplyState',
|
|
'dell_pwr_desc' => 'rlEnvMonSupplyStatusDescr',
|
|
|
|
# RADLAN-HWENVIROMENT:rlEnvMonFanStatusTable
|
|
'dell_fan_state' => 'rlEnvMonFanState',
|
|
'dell_fan_desc' => 'rlEnvMonFanStatusDescr',
|
|
);
|
|
|
|
%MUNGE = ( %SNMP::Info::Layer3::MUNGE, );
|
|
|
|
# Method OverRides
|
|
|
|
sub model {
|
|
my $dell = shift;
|
|
|
|
my $name = $dell->dell_id_name();
|
|
my $id = $dell->id();
|
|
|
|
if ( defined $name and $name =~ m/(\d+)/ ) {
|
|
return $1;
|
|
}
|
|
|
|
return unless defined $id;
|
|
|
|
my $model = SNMP::translateObj($id);
|
|
|
|
if (defined $model) {
|
|
$model =~ s/^dell//;
|
|
$model =~ s/Switch$//;
|
|
return $model;
|
|
}
|
|
return $id;
|
|
}
|
|
|
|
sub vendor {
|
|
my $dell = shift;
|
|
|
|
return $dell->_vendor();
|
|
}
|
|
|
|
sub os {
|
|
my $dell = shift;
|
|
|
|
return $dell->_vendor();
|
|
}
|
|
|
|
sub os_ver {
|
|
my $dell = shift;
|
|
|
|
my $entity_os = $dell->entity_derived_os_ver();
|
|
if ( defined $entity_os and $entity_os !~ /^\s*$/ ){
|
|
return $entity_os;
|
|
}
|
|
|
|
my $dell_os = $dell->dell_os_ver();
|
|
if ( defined $dell_os and $dell_os !~ /^\s*$/ ) {
|
|
return $dell_os;
|
|
}
|
|
return;
|
|
}
|
|
|
|
# check all fans, and report overall status
|
|
sub fan {
|
|
my $dell = shift;
|
|
|
|
my $fan = $dell->dell_fan_desc() || {};
|
|
my $state = $dell->dell_fan_state() || {};
|
|
|
|
if (scalar keys %$fan) {
|
|
my @messages = ();
|
|
|
|
foreach my $k (keys %$fan) {
|
|
next if $state->{$k} and $state->{$k} eq 'normal';
|
|
push @messages, "$fan->{$k}: $state->{$k}";
|
|
}
|
|
|
|
push @messages, ((scalar keys %$fan). " fans OK")
|
|
if scalar @messages == 0;
|
|
|
|
return (join ", ", @messages);
|
|
}
|
|
return;
|
|
}
|
|
|
|
sub ps1_type {
|
|
my $dell = shift;
|
|
|
|
my $src = $dell->dell_pwr_src() || {};
|
|
|
|
foreach my $k (sort keys %$src) {
|
|
next unless $src->{$k};
|
|
return $src->{$k};
|
|
}
|
|
return;
|
|
}
|
|
|
|
sub ps2_type {
|
|
my $dell = shift;
|
|
|
|
my $src = $dell->dell_pwr_src() || {};
|
|
|
|
my $i = 0;
|
|
foreach my $k (sort keys %$src) {
|
|
$i++;
|
|
next unless $src->{$k} and $i == 2;
|
|
return $src->{$k};
|
|
}
|
|
return;
|
|
}
|
|
|
|
sub ps1_status {
|
|
my $dell = shift;
|
|
|
|
my $status = $dell->dell_pwr_state() || {};
|
|
|
|
foreach my $k (sort keys %$status) {
|
|
next unless $status->{$k};
|
|
return $status->{$k};
|
|
}
|
|
return;
|
|
}
|
|
|
|
sub ps2_status {
|
|
my $dell = shift;
|
|
|
|
my $status = $dell->dell_pwr_state() || {};
|
|
|
|
my $i = 0;
|
|
foreach my $k (sort keys %$status) {
|
|
$i++;
|
|
next unless $status->{$k} and $i == 2;
|
|
return $status->{$k};
|
|
}
|
|
return;
|
|
}
|
|
|
|
sub interfaces {
|
|
my $dell = shift;
|
|
my $partial = shift;
|
|
|
|
my $i_descr = $dell->i_description($partial) || {};
|
|
my $i_name = $dell->orig_i_name($partial) || {};
|
|
|
|
# Descriptions are all the same on some Dells, so use name instead if
|
|
# available
|
|
foreach my $iid ( keys %$i_name ) {
|
|
my $name = $i_name->{$iid};
|
|
next unless defined $name;
|
|
$i_descr->{$iid} = $name;
|
|
}
|
|
|
|
return $i_descr;
|
|
}
|
|
|
|
sub i_duplex {
|
|
my $dell = shift;
|
|
my $partial = shift;
|
|
|
|
my $dell_duplex = $dell->dell_duplex($partial) || {};
|
|
|
|
my %i_duplex;
|
|
foreach my $if ( keys %$dell_duplex ) {
|
|
my $duplex = $dell_duplex->{$if};
|
|
next unless defined $duplex;
|
|
next if $duplex eq 'unknown';
|
|
|
|
$i_duplex{$if} = $duplex;
|
|
}
|
|
return \%i_duplex;
|
|
}
|
|
|
|
sub i_duplex_admin {
|
|
my $dell = shift;
|
|
my $partial = shift;
|
|
|
|
my $interfaces = $dell->interfaces($partial) || {};
|
|
my $dell_duplex = $dell->dell_duplex_admin($partial) || {};
|
|
my $dell_auto = $dell->dell_auto($partial) || {};
|
|
|
|
my %i_duplex_admin;
|
|
foreach my $if ( keys %$interfaces ) {
|
|
my $duplex = $dell_duplex->{$if};
|
|
next unless defined $duplex;
|
|
my $auto = $dell_auto->{$if} || 'disabled';
|
|
|
|
$duplex = 'half' if ( $duplex eq 'half' and $auto eq 'disabled' );
|
|
$duplex = 'full' if ( $duplex eq 'full' and $auto eq 'disabled' );
|
|
$duplex = 'auto' if $auto eq 'enabled';
|
|
$i_duplex_admin{$if} = $duplex;
|
|
}
|
|
return \%i_duplex_admin;
|
|
}
|
|
|
|
sub _vendor {
|
|
my $dell = shift;
|
|
|
|
my $id = $dell->id() || 'undef';
|
|
my %oidmap = (
|
|
2 => 'ibm',
|
|
674 => 'dell',
|
|
3955 => 'linksys',
|
|
);
|
|
$id = $1 if ( defined($id) && $id =~ /^\.1\.3\.6\.1\.4\.1\.(\d+)/ );
|
|
|
|
if ( defined($id) and exists( $oidmap{$id} ) ) {
|
|
return $oidmap{$id};
|
|
}
|
|
else {
|
|
return $id;
|
|
}
|
|
}
|
|
|
|
# dot1qTpFdbTable uses dot1qVlanIndex rather than dot1qFdbId as index,
|
|
# so pretend we don't have the mapping
|
|
sub qb_fdb_index {return}
|
|
|
|
1;
|
|
__END__
|
|
|
|
=head1 NAME
|
|
|
|
SNMP::Info::Layer3::Dell - SNMP Interface to Dell Power Connect Network
|
|
Devices
|
|
|
|
=head1 AUTHOR
|
|
|
|
Eric Miller
|
|
|
|
=head1 SYNOPSIS
|
|
|
|
# Let SNMP::Info determine the correct subclass for you.
|
|
my $dell = new SNMP::Info(
|
|
AutoSpecify => 1,
|
|
Debug => 1,
|
|
DestHost => 'myswitch',
|
|
Community => 'public',
|
|
Version => 2
|
|
)
|
|
or die "Can't connect to DestHost.\n";
|
|
|
|
my $class = $dell->class();
|
|
|
|
print "SNMP::Info determined this device to fall under subclass : $class\n";
|
|
|
|
=head1 DESCRIPTION
|
|
|
|
Provides abstraction to the configuration information obtainable from an
|
|
Dell Power Connect device through SNMP. D-Link and the IBM BladeCenter
|
|
Gigabit Ethernet Switch Module also use this module based upon MIB support.
|
|
|
|
For speed or debugging purposes you can call the subclass directly, but not
|
|
after determining a more specific class using the method above.
|
|
|
|
my $dell = new SNMP::Info::Layer3::Dell(...);
|
|
|
|
=head2 Inherited Classes
|
|
|
|
=over
|
|
|
|
=item SNMP::Info::Layer3
|
|
|
|
=back
|
|
|
|
=head2 Required MIBs
|
|
|
|
=over
|
|
|
|
=item F<DELL-REF-MIB>
|
|
|
|
=item F<Dell-Vendor-MIB>
|
|
|
|
=item F<RADLAN-COPY-MIB>
|
|
|
|
=item F<RADLAN-HWENVIROMENT>
|
|
|
|
=item F<RADLAN-Physicaldescription-MIB>
|
|
|
|
=item F<RADLAN-rlInterfaces>
|
|
|
|
=item Inherited Classes' MIBs
|
|
|
|
See classes listed above for their required MIBs.
|
|
|
|
=back
|
|
|
|
=head1 GLOBALS
|
|
|
|
These are methods that return scalar value from SNMP
|
|
|
|
=over
|
|
|
|
=item $dell->os_ver()
|
|
|
|
(C<productIdentificationVersion>)
|
|
|
|
=item $dell->dell_id_name()
|
|
|
|
(C<productIdentificationDisplayName>)
|
|
|
|
=item $dell->model()
|
|
|
|
Returns model type. Returns numeric from
|
|
(C<productIdentificationDisplayName>) if available, otherwise if returns
|
|
description().
|
|
|
|
=item $dell->vendor()
|
|
|
|
Returns 'dell', 'dlink', or 'ibm' based upon the IANA enterprise number in
|
|
id(). Defaults to 'dlink'.
|
|
|
|
=item $dell->os()
|
|
|
|
Returns 'dell', 'dlink', or 'ibm' based upon the IANA enterprise number in
|
|
id(). Defaults to 'dlink'.
|
|
|
|
=item $dell->fan()
|
|
|
|
Return the status of all fans from the F<Dell-Vendor-MIB>
|
|
|
|
=item $dell->ps1_type()
|
|
|
|
Return the type of the first power supply from the F<Dell-Vendor-MIB>
|
|
|
|
=item $dell->ps2_type()
|
|
|
|
Return the type of the second power supply from the F<Dell-Vendor-MIB>
|
|
|
|
=item $dell->ps1_status()
|
|
|
|
Return the status of the first power supply from the F<Dell-Vendor-MIB>
|
|
|
|
=item $dell->ps2_status()
|
|
|
|
Return the status of the second power supply from the F<Dell-Vendor-MIB>
|
|
|
|
=back
|
|
|
|
=head2 Overrides
|
|
|
|
=over
|
|
|
|
=item $dell->serial()
|
|
|
|
Returns serial number. Returns (C<rlPhdUnitGenParamSerialNum>) if available,
|
|
otherwise uses the Layer3 serial method.
|
|
|
|
=back
|
|
|
|
=head2 Globals imported from SNMP::Info::Layer3
|
|
|
|
See documentation in L<SNMP::Info::Layer3/"GLOBALS"> for details.
|
|
|
|
=head1 TABLE METHODS
|
|
|
|
These are methods that return tables of information in the form of a reference
|
|
to a hash.
|
|
|
|
=head2 RADLAN Interface Table (C<swIfTable>)
|
|
|
|
=over
|
|
|
|
=item $dell->dell_duplex_admin()
|
|
|
|
(C<swIfDuplexAdminMode>)
|
|
|
|
=item $dell->dell_duplex()
|
|
|
|
(C<swIfDuplexOperMode>)
|
|
|
|
=item $dell->dell_tag_mode()
|
|
|
|
(C<swIfTaggedMode>)
|
|
|
|
=item $dell->dell_i_type()
|
|
|
|
(C<swIfType>)
|
|
|
|
=item $dell->dell_fc_admin()
|
|
|
|
(C<swIfFlowControlMode>)
|
|
|
|
=item $dell->dell_speed_admin()
|
|
|
|
(C<swIfSpeedAdminMode>)
|
|
|
|
=item $dell->dell_auto()
|
|
|
|
(C<swIfSpeedDuplexAutoNegotiation>)
|
|
|
|
=item $dell->dell_fc()
|
|
|
|
(C<swIfOperFlowControlMode>)
|
|
|
|
=back
|
|
|
|
=head2 Overrides
|
|
|
|
=over
|
|
|
|
=item $dell->interfaces()
|
|
|
|
Returns the map between SNMP Interface Identifier (iid) and physical port
|
|
name. Uses name if available instead of description since descriptions are
|
|
sometimes not unique.
|
|
|
|
=item $dell->i_duplex()
|
|
|
|
Returns reference to map of IIDs to current link duplex.
|
|
|
|
=item $dell->i_duplex_admin()
|
|
|
|
Returns reference to hash of iid to current link administrative duplex
|
|
setting.
|
|
|
|
=item $dell->qb_fdb_index()
|
|
|
|
Returns nothing to work around incorrect indexing of C<dot1qTpFdbTable>
|
|
|
|
=back
|
|
|
|
=head2 Table Methods imported from SNMP::Info::Layer3
|
|
|
|
See documentation in L<SNMP::Info::Layer3/"TABLE METHODS"> for details.
|
|
|
|
=cut
|