| # SNMP::Info::Layer3::Foundry - SNMP Interface to Foundry devices
 | |
| # Max Baker
 | |
| #
 | |
| # Copyright (c) 2004,2005 Max Baker changes from version 0.8 and beyond.
 | |
| #
 | |
| # Copyright (c) 2002,2003 Regents of the University of California
 | |
| # All rights reserved.
 | |
| # 
 | |
| # Redistribution and use in source and binary forms, with or without 
 | |
| # modification, are permitted provided that the following conditions are met:
 | |
| # 
 | |
| #     * Redistributions of source code must retain the above copyright notice,
 | |
| #       this list of conditions and the following disclaimer.
 | |
| #     * Redistributions in binary form must reproduce the above copyright notice,
 | |
| #       this list of conditions and the following disclaimer in the documentation
 | |
| #       and/or other materials provided with the distribution.
 | |
| #     * Neither the name of the University of California, Santa Cruz nor the 
 | |
| #       names of its contributors may be used to endorse or promote products 
 | |
| #       derived from this software without specific prior written permission.
 | |
| # 
 | |
| # THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND
 | |
| # ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED 
 | |
| # WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE 
 | |
| # DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR
 | |
| # ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
 | |
| # (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; 
 | |
| # LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON
 | |
| # ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT 
 | |
| # (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS 
 | |
| # SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
 | |
| 
 | |
| package SNMP::Info::Layer3::Foundry;
 | |
| # $Id$
 | |
| 
 | |
| use strict;
 | |
| 
 | |
| use Exporter;
 | |
| use SNMP::Info::Layer3;
 | |
| use SNMP::Info::FDP;
 | |
| 
 | |
| use vars qw/$VERSION $DEBUG %GLOBALS %FUNCS $INIT %MIBS %MUNGE/;
 | |
| 
 | |
| $VERSION = 1.0;
 | |
| 
 | |
| @SNMP::Info::Layer3::Foundry::ISA = qw/SNMP::Info::Layer3 SNMP::Info::FDP Exporter/;
 | |
| @SNMP::Info::Layer3::Foundry::EXPORT_OK = qw//;
 | |
| 
 | |
| %MIBS = ( %SNMP::Info::Layer3::MIBS,
 | |
|           %SNMP::Info::FDP::MIBS,
 | |
|           'FOUNDRY-SN-ROOT-MIB' => 'foundry',
 | |
|           'FOUNDRY-SN-AGENT-MIB' => 'snChasPwrSupplyDescription',
 | |
|           # IP-FORWARD-MIB
 | |
|           # ETHERLIKE-MIB
 | |
|           # RFC1398-MIB
 | |
|           # RMON-MIB
 | |
|           # IF-MIB
 | |
|         );
 | |
| 
 | |
| %GLOBALS = (
 | |
|             %SNMP::Info::Layer3::GLOBALS,
 | |
|             %SNMP::Info::FDP::GLOBALS,
 | |
|             'mac'        => 'ifPhysAddress.1',
 | |
|             'chassis'    => 'entPhysicalDescr.1',
 | |
|             'serial'     => 'snChasSerNum',
 | |
|             'temp'       => 'snChasActualTemperature',
 | |
|             'ps1_type'   => 'snChasPwrSupplyDescription.1',
 | |
|             'ps1_status' => 'snChasPwrSupplyOperStatus.1',
 | |
|             'fan'        => 'snChasFanOperStatus.1',
 | |
|             #'serial'   => 'enterprises.1991.1.1.1.1.2.0',
 | |
|             #'temp'     => 'enterprises.1991.1.1.1.1.18.0',
 | |
|             #'ps1_type' => 'enterprises.1991.1.1.1.2.1.1.2.1',
 | |
|             #'ps1_status' => 'enterprises.1991.1.1.1.2.1.1.3.1',
 | |
|             #'fan'   => 'enterprises.1991.1.1.1.3.1.1.3.1'
 | |
|            );
 | |
| 
 | |
| %FUNCS   = (
 | |
|             %SNMP::Info::Layer3::FUNCS,
 | |
|             %SNMP::Info::FDP::FUNCS,
 | |
|             'i_name2'    => 'ifName',
 | |
|             # FOUNDRY-MIB
 | |
|             #   snSwPortInfoTable - Switch Port Information Group
 | |
|             'sw_index'    => 'snSwPortIfIndex',
 | |
|             'sw_duplex'   => 'snSwPortInfoChnMode',
 | |
|             'sw_type'     => 'snSwPortInfoMediaType',
 | |
|             'sw_speed'    => 'snSwPortInfoSpeed',
 | |
|            );
 | |
| 
 | |
| %MUNGE = (
 | |
|             # Inherit all the built in munging
 | |
|             %SNMP::Info::Layer3::MUNGE,
 | |
|             %SNMP::Info::FDP::MUNGE,
 | |
|             'at_paddr' => \&SNMP::Info::munge_mac,
 | |
|          );
 | |
| 
 | |
| 
 | |
| # Method OverRides
 | |
| 
 | |
| sub bulkwalk_no { 1; }
 | |
| 
 | |
| # Add our i_aliases if they are set (manually)
 | |
| sub i_name {
 | |
|     my $foundry = shift;
 | |
|     my $i_name = $foundry->i_name2();
 | |
| 
 | |
|     my $i_alias = $foundry->i_alias();
 | |
| 
 | |
|     foreach my $iid (keys %$i_name){
 | |
|         my $alias = $i_alias->{$iid};
 | |
|         next unless defined $alias;
 | |
|         next unless length($alias);
 | |
|         $i_name->{$iid} = $i_alias->{$iid};
 | |
|     }
 | |
| 
 | |
|     return $i_name;
 | |
| }
 | |
| 
 | |
| sub i_ignore {
 | |
|     my $foundry = shift;
 | |
|     
 | |
|     my $interfaces = $foundry->interfaces();
 | |
|     my $i_descr    = $foundry->i_descr();
 | |
| 
 | |
|     my %i_ignore;
 | |
|     foreach my $if (keys %$interfaces) {
 | |
|         # lo -> cisco aironet 350 loopback
 | |
|         if ($interfaces->{$if} =~ /(tunnel|loopback|lo|lb|null)/i){
 | |
|             $i_ignore{$if}++;
 | |
|         }
 | |
|     }
 | |
|     return \%i_ignore;
 | |
| }
 | |
| 
 | |
| sub i_duplex {
 | |
|     my $foundry = shift;
 | |
|     my $sw_index = $foundry->sw_index();
 | |
|     my $sw_duplex= $foundry->sw_duplex();
 | |
| 
 | |
|     unless (defined $sw_index and defined $sw_duplex){
 | |
|        return $foundry->SUPER::i_duplex(); 
 | |
|     }
 | |
|     
 | |
|     my %i_duplex;
 | |
|     foreach my $sw_port (keys %$sw_duplex){
 | |
|         my $iid = $sw_index->{$sw_port};
 | |
|         my $duplex = $sw_duplex->{$sw_port};
 | |
|         next if $duplex =~ /none/i;
 | |
|         $i_duplex{$iid} = 'half' if $duplex =~ /half/i;
 | |
|         $i_duplex{$iid} = 'full' if $duplex =~ /full/i;
 | |
|     }
 | |
|     return \%i_duplex;
 | |
| }
 | |
| 
 | |
| sub i_type {
 | |
|     my $foundry = shift;
 | |
|     my $sw_index = $foundry->sw_index();
 | |
|     my $sw_type= $foundry->sw_type();
 | |
| 
 | |
|     unless (defined $sw_index and defined $sw_type){
 | |
|        return $foundry->SUPER::i_type(); 
 | |
|     }
 | |
|     
 | |
|     my %i_type;
 | |
|     foreach my $sw_port (keys %$sw_type){
 | |
|         my $iid = $sw_index->{$sw_port};
 | |
|         my $type = $sw_type->{$sw_port};
 | |
|         next unless defined $type;
 | |
|         $i_type{$iid} = $type;
 | |
|     }
 | |
|     return \%i_type;
 | |
| }
 | |
| 
 | |
| sub i_speed {
 | |
|     my $foundry = shift;
 | |
|     my $sw_index = $foundry->sw_index();
 | |
|     my $sw_speed= $foundry->sw_speed();
 | |
| 
 | |
|     unless (defined $sw_index and defined $sw_speed){
 | |
|        return $foundry->SUPER::i_speed(); 
 | |
|     }
 | |
|     
 | |
|     my %i_speed;
 | |
|     foreach my $sw_port (keys %$sw_speed){
 | |
|         my $iid = $sw_index->{$sw_port};
 | |
|         my $speed = $sw_speed->{$sw_port};
 | |
|         next unless defined $speed;
 | |
|         $speed = 'auto'     if $speed =~ /auto/i;
 | |
|         $speed = '10 Mbps'  if $speed =~ /s10m/i;
 | |
|         $speed = '100 Mbps' if $speed =~ /s100m/i;
 | |
|         $speed = '1.0 Gbps' if $speed =~ /s1g/i;
 | |
|         $speed = '45 Mbps' if $speed =~ /s45M/i;
 | |
|         $speed = '155 Mbps' if $speed =~ /s155M/i;
 | |
|         $i_speed{$iid} = $speed;
 | |
|     }
 | |
|     return \%i_speed;
 | |
| }
 | |
| 
 | |
| # $foundry->model() - looks for xxnnnn in the description
 | |
| sub model {
 | |
|     my $foundry = shift;
 | |
|     my $id = $foundry->id();
 | |
|     my $desc = $foundry->description();
 | |
|     my $model = &SNMP::translateObj($id);
 | |
| 
 | |
|     $model = $1 if $desc =~ /\s+([a-z]{2}\d{4})\D/i;
 | |
|     $model = $1 if $desc =~ /\b(FW[A-Z\d]+)/;
 | |
| 
 | |
|     $model =~ s/^sn//;
 | |
| 
 | |
|     return $model;
 | |
| }
 | |
| 
 | |
| sub os {
 | |
|     my $foundry = shift;
 | |
|     my $descr = $foundry->description();
 | |
|     if ($descr =~ m/IronWare/i) {
 | |
|         return 'IronWare';
 | |
|     }
 | |
| 
 | |
|     return 'foundry';
 | |
| }
 | |
| sub os_ver {
 | |
|     my $foundry = shift;
 | |
|     my $os_version = $foundry->os_version();
 | |
|     return $os_version if defined $os_version;
 | |
|     # Some older ones don't have this value,so we cull it from the description
 | |
|     my $descr = $foundry->description();
 | |
|     if ($descr =~ m/Version (\d\S*)/) {
 | |
|         return $1;
 | |
|     }
 | |
|     return undef;
 | |
| }
 | |
| 
 | |
| 
 | |
| # $foundry->interfaces() - Map the Interfaces to their physical names
 | |
| sub interfaces {
 | |
|     my $foundry = shift;
 | |
|     my $interfaces = $foundry->i_index();
 | |
|     
 | |
|     my $descriptions = $foundry->i_description();
 | |
| 
 | |
|     my %ifs = ();
 | |
|     foreach my $iid (keys %$interfaces){
 | |
|         $ifs{$iid} = $descriptions->{$iid}; 
 | |
|     }
 | |
|     
 | |
|     return \%ifs;
 | |
| }
 | |
| 
 | |
| sub vendor {
 | |
|     return 'foundry';
 | |
| }
 | |
| 
 | |
| 1;
 | |
| __END__
 | |
| 
 | |
| =head1 NAME
 | |
| 
 | |
| SNMP::Info::Layer3::Foundry - Perl5 Interface to Foundry FastIron Network Devices
 | |
| 
 | |
| =head1 AUTHOR
 | |
| 
 | |
| Max Baker
 | |
| 
 | |
| =head1 SYNOPSIS
 | |
| 
 | |
|  # Let SNMP::Info determine the correct subclass for you. 
 | |
|  my $foundry = new SNMP::Info(
 | |
|                           AutoSpecify => 1,
 | |
|                           Debug       => 1,
 | |
|                           # These arguments are passed directly on to SNMP::Session
 | |
|                           DestHost    => 'myswitch',
 | |
|                           Community   => 'public',
 | |
|                           Version     => 1
 | |
|                         ) 
 | |
|     or die "Can't connect to DestHost.\n";
 | |
| 
 | |
|  my $class      = $foundry->class();
 | |
| 
 | |
|  print "SNMP::Info determined this device to fall under subclass : $class\n";
 | |
| 
 | |
| =head1 DESCRIPTION
 | |
| 
 | |
| This module provides limited functionality from some L2+L3 and L3 Foundry devices.
 | |
| 
 | |
| Specifically designed for a FI4802. Works on a FWSX424.
 | |
| 
 | |
| For speed or debugging purposes you can call the subclass directly, but not after determining
 | |
| a more specific class using the method above.  Turn off the AutoSpecify flag.
 | |
| 
 | |
|  my $foundry = new SNMP::Info::Layer3::Foundry(...);
 | |
| 
 | |
| =head2 Inherited Classes
 | |
| 
 | |
| =over
 | |
| 
 | |
| =item SNMP::Info
 | |
| 
 | |
| 
 | |
| =back
 | |
| 
 | |
| =head2 Required MIBs
 | |
| 
 | |
| =over
 | |
| 
 | |
| =item FOUNDRY-SN-ROOT-MIB
 | |
| 
 | |
| =item Inherited Classes' MIBs
 | |
| 
 | |
| See classes listed above for their required MIBs.
 | |
| 
 | |
| =back
 | |
| 
 | |
| The Foundry MIBS can be downloaded from www.mibdepot.com and ??
 | |
| 
 | |
| =head1 GLOBALS
 | |
| 
 | |
| These are methods that return scalar value from SNMP
 | |
| 
 | |
| =over
 | |
| 
 | |
| =item $foundry->model()
 | |
| 
 | |
| Returns model type.  Checks $foundry->id() against the 
 | |
| FOUNDRY-SN-ROOT-MIB and then parses out xxNNNN
 | |
| 
 | |
| =item $foundry->vendor()
 | |
| 
 | |
| Returns 'foundry' :)
 | |
| 
 | |
| =item $foundry->mac()
 | |
| 
 | |
| Returns MAC Address of root port.
 | |
| 
 | |
| (B<ifPhysAddress.1>)
 | |
| 
 | |
| =item $foundry->chassis()
 | |
| 
 | |
| Returns Chassis type.
 | |
| 
 | |
| (B<entPhysicalDescr.1>)
 | |
| 
 | |
| =item $foundry->serial()
 | |
| 
 | |
| Returns serial number of device.
 | |
| 
 | |
| (B<snChasSerNum>)
 | |
| 
 | |
| =item $foundry->temp()
 | |
| 
 | |
| Returns the chassis temperature
 | |
| 
 | |
| (B<snChasActualTemperature>)
 | |
| 
 | |
| =item $foundry->ps1_type()
 | |
| 
 | |
| Returns the Description for the power supply
 | |
| 
 | |
| (B<snChasPwrSupplyDescription.1>)
 | |
| 
 | |
| =item $foundry->ps1_status()
 | |
| 
 | |
| Returns the status of the power supply.
 | |
| 
 | |
| (B<snChasPwrSupplyOperStatus.1>)
 | |
| 
 | |
| =item $foundry->fan()
 | |
| 
 | |
| Returns the status of the chassis fan.
 | |
| 
 | |
| (B<snChasFanOperStatus.1>)
 | |
| 
 | |
| =back
 | |
| 
 | |
| =head2 Globals imported from SNMP::Info
 | |
| 
 | |
| See documentation in SNMP::Info for details.
 | |
| 
 | |
| =head1 TABLE ENTRIES
 | |
| 
 | |
| These are methods that return tables of information in the form of a reference
 | |
| to a hash.
 | |
| 
 | |
| =head2 Overrides
 | |
| 
 | |
| =over
 | |
| 
 | |
| =item $foundry->interfaces()
 | |
| 
 | |
| Returns reference to hash of interface names to iids.
 | |
| 
 | |
| Uses B<ifDescr>.
 | |
| 
 | |
| =item $foundry->i_name()
 | |
| 
 | |
| Returns reference to hash of interface names.  
 | |
| Trys for B<ifAlias> and Defaults to B<ifName>
 | |
| 
 | |
| =item $foundry->i_ignore()
 | |
| 
 | |
| Returns reference to hash of interfaces to be ignored.
 | |
| 
 | |
| Ignores interfaces with descriptions of  tunnel,loopback,null 
 | |
| 
 | |
| =item $foundry->i_duplex()
 | |
| 
 | |
| Returns reference to hash of interface link duplex status. 
 | |
| 
 | |
| Crosses $foundry->sw_duplex() with $foundry->sw_index()
 | |
| 
 | |
| =item $foundry->i_type()
 | |
| 
 | |
| Returns reference to hash of interface types.
 | |
| 
 | |
| Crosses $foundry->sw_type() with $foundry->sw_index()
 | |
| 
 | |
| =item $foundry->i_speed()
 | |
| 
 | |
| Returns reference to hash of interface speeds .
 | |
| 
 | |
| Crosses $foundry->sw_speeD() with $foundry->sw_index() and 
 | |
| does a little munging.
 | |
| 
 | |
| =back
 | |
| 
 | |
| =head2 RFC1213 Arp Cache Table (B<ipNetToMediaTable>)
 | |
| 
 | |
| =over
 | |
| 
 | |
| =item $foundry->at_index()
 | |
| 
 | |
| Returns reference to hash.  Maps ARP table entries to Interface IIDs 
 | |
| 
 | |
| (B<ipNetToMediaIfIndex>)
 | |
| 
 | |
| =item $foundry->at_paddr()
 | |
| 
 | |
| Returns reference to hash.  Maps ARP table entries to MAC addresses. 
 | |
| 
 | |
| (B<ipNetToMediaPhysAddress>)
 | |
| 
 | |
| =item $foundry->at_netaddr()
 | |
| 
 | |
| Returns reference to hash.  Maps ARP table entries to IPs 
 | |
| 
 | |
| (B<ipNetToMediaNetAddress>)
 | |
| 
 | |
| =back
 | |
| 
 | |
| =head2 Foundry Switch Port Information Table (B<snSwPortIfTable>)
 | |
| 
 | |
| =over
 | |
| 
 | |
| =item $foundry->sw_index()
 | |
| 
 | |
| Returns reference to hash.  Maps Table to Interface IID. 
 | |
| 
 | |
| (B<snSwPortIfIndex>)
 | |
| 
 | |
| =item $foundry->sw_duplex()
 | |
| 
 | |
| Returns reference to hash.   Current duplex status for switch ports. 
 | |
| 
 | |
| (B<snSwPortInfoChnMode>)
 | |
| 
 | |
| =item $foundry->sw_type()
 | |
| 
 | |
| Returns reference to hash.  Current Port Type .
 | |
| 
 | |
| (B<snSwPortInfoMediaType>)
 | |
| 
 | |
| =item $foundry->sw_speed()
 | |
| 
 | |
| Returns reference to hash.  Current Port Speed. 
 | |
| 
 | |
| (B<snSwPortInfoSpeed>)
 | |
| 
 | |
| =back
 | |
| 
 | |
| =head2 Table Methods imported from SNMP::Info
 | |
| 
 | |
| See documentation in SNMP::Info for details.
 | |
| 
 | |
| =cut
 | 