416 lines
		
	
	
		
			12 KiB
		
	
	
	
		
			Perl
		
	
	
	
	
	
			
		
		
	
	
			416 lines
		
	
	
		
			12 KiB
		
	
	
	
		
			Perl
		
	
	
	
	
	
# SNMP::Info::Layer3::C6500
 | 
						|
# Max Baker
 | 
						|
#
 | 
						|
# Copyright (c) 2003,2004,2005 Max Baker
 | 
						|
# All rights reserved.
 | 
						|
# 
 | 
						|
# Redistribution and use in source and binary forms, with or without 
 | 
						|
# modification, are permitted provided that the following conditions are met:
 | 
						|
# 
 | 
						|
#     * Redistributions of source code must retain the above copyright notice,
 | 
						|
#       this list of conditions and the following disclaimer.
 | 
						|
#     * Redistributions in binary form must reproduce the above copyright notice,
 | 
						|
#       this list of conditions and the following disclaimer in the documentation
 | 
						|
#       and/or other materials provided with the distribution.
 | 
						|
#     * Neither the name of the Author, nor 
 | 
						|
#       names of its contributors may be used to endorse or promote products 
 | 
						|
#       derived from this software without specific prior written permission.
 | 
						|
# 
 | 
						|
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND
 | 
						|
# ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED 
 | 
						|
# WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE 
 | 
						|
# DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR
 | 
						|
# ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
 | 
						|
# (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; 
 | 
						|
# LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON
 | 
						|
# ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT 
 | 
						|
# (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS 
 | 
						|
# SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
 | 
						|
 | 
						|
package SNMP::Info::Layer3::C6500;
 | 
						|
# $Id$
 | 
						|
 | 
						|
use strict;
 | 
						|
 | 
						|
use Exporter;
 | 
						|
use SNMP::Info::CiscoVTP;
 | 
						|
use SNMP::Info::CiscoStack;
 | 
						|
use SNMP::Info::CDP;
 | 
						|
use SNMP::Info::CiscoStats;
 | 
						|
use SNMP::Info::CiscoImage;
 | 
						|
use SNMP::Info::CiscoPortSecurity;
 | 
						|
use SNMP::Info::CiscoConfig;
 | 
						|
use SNMP::Info::CiscoPower;
 | 
						|
use SNMP::Info::Layer3;
 | 
						|
 | 
						|
use vars qw/$VERSION $DEBUG %GLOBALS %MIBS %FUNCS %MUNGE $INIT/ ;
 | 
						|
$VERSION = '1.07';
 | 
						|
@SNMP::Info::Layer3::C6500::ISA = qw/SNMP::Info::CiscoVTP SNMP::Info::CiscoStack 
 | 
						|
                                    SNMP::Info::CDP SNMP::Info::CiscoStats 
 | 
						|
                                    SNMP::Info::CiscoImage 
 | 
						|
                                    SNMP::Info::CiscoPortSecurity
 | 
						|
                                    SNMP::Info::CiscoConfig
 | 
						|
                                    SNMP::Info::CiscoPower
 | 
						|
                                    SNMP::Info::Layer3
 | 
						|
                                    Exporter/;
 | 
						|
@SNMP::Info::Layer3::C6500::EXPORT_OK = qw//;
 | 
						|
 | 
						|
%MIBS =    (
 | 
						|
            %SNMP::Info::Layer3::MIBS,
 | 
						|
            %SNMP::Info::CiscoPower::MIBS,
 | 
						|
            %SNMP::Info::CiscoConfig::MIBS,
 | 
						|
            %SNMP::Info::CiscoPortSecurity::MIBS,
 | 
						|
            %SNMP::Info::CiscoImage::MIBS,
 | 
						|
            %SNMP::Info::CiscoStats::MIBS,
 | 
						|
            %SNMP::Info::CDP::MIBS,
 | 
						|
            %SNMP::Info::CiscoStack::MIBS,
 | 
						|
            %SNMP::Info::CiscoVTP::MIBS,
 | 
						|
           );
 | 
						|
 | 
						|
%GLOBALS = (
 | 
						|
            %SNMP::Info::Layer3::GLOBALS,
 | 
						|
            %SNMP::Info::CiscoPower::GLOBALS,
 | 
						|
            %SNMP::Info::CiscoConfig::GLOBALS,
 | 
						|
            %SNMP::Info::CiscoPortSecurity::GLOBALS,
 | 
						|
            %SNMP::Info::CiscoImage::GLOBALS,
 | 
						|
            %SNMP::Info::CiscoStats::GLOBALS,
 | 
						|
            %SNMP::Info::CDP::GLOBALS,
 | 
						|
            %SNMP::Info::CiscoStack::GLOBALS,
 | 
						|
            %SNMP::Info::CiscoVTP::GLOBALS,
 | 
						|
           );
 | 
						|
 | 
						|
%FUNCS = (
 | 
						|
            %SNMP::Info::Layer3::FUNCS,
 | 
						|
            %SNMP::Info::CiscoPower::FUNCS,
 | 
						|
            %SNMP::Info::CiscoConfig::FUNCS,
 | 
						|
            %SNMP::Info::CiscoPortSecurity::FUNCS,
 | 
						|
            %SNMP::Info::CiscoImage::FUNCS,
 | 
						|
            %SNMP::Info::CiscoStats::FUNCS,
 | 
						|
            %SNMP::Info::CDP::FUNCS,
 | 
						|
            %SNMP::Info::CiscoStack::FUNCS,
 | 
						|
            %SNMP::Info::CiscoVTP::FUNCS,
 | 
						|
         );
 | 
						|
 | 
						|
%MUNGE = (
 | 
						|
            %SNMP::Info::Layer3::MUNGE,
 | 
						|
            %SNMP::Info::CiscoPower::MUNGE,
 | 
						|
            %SNMP::Info::CiscoConfig::MUNGE,
 | 
						|
            %SNMP::Info::CiscoPortSecurity::MUNGE,
 | 
						|
            %SNMP::Info::CiscoImage::MUNGE,
 | 
						|
            %SNMP::Info::CiscoStats::MUNGE,
 | 
						|
            %SNMP::Info::CDP::MUNGE,
 | 
						|
            %SNMP::Info::CiscoStack::MUNGE,
 | 
						|
            %SNMP::Info::CiscoVTP::MUNGE,
 | 
						|
         );
 | 
						|
 | 
						|
sub vendor {
 | 
						|
    return 'cisco';
 | 
						|
}
 | 
						|
 | 
						|
sub cisco_comm_indexing { 1; }
 | 
						|
 | 
						|
#  Newer versions use the ETHERLIKE-MIB to report operational duplex.
 | 
						|
 | 
						|
sub i_duplex {
 | 
						|
    my $c6500 = shift;
 | 
						|
    my $partial = shift;
 | 
						|
 | 
						|
    my $el_duplex = $c6500->el_duplex($partial);
 | 
						|
 | 
						|
    # Newer software     
 | 
						|
    if (defined $el_duplex and scalar(keys %$el_duplex)){
 | 
						|
        my %i_duplex;
 | 
						|
        foreach my $el_port (keys %$el_duplex){
 | 
						|
            my $duplex = $el_duplex->{$el_port};
 | 
						|
            next unless defined $duplex;
 | 
						|
 | 
						|
            $i_duplex{$el_port} = 'half' if $duplex =~ /half/i;
 | 
						|
            $i_duplex{$el_port} = 'full' if $duplex =~ /full/i;
 | 
						|
        }
 | 
						|
        return \%i_duplex;
 | 
						|
    }
 | 
						|
    # Fall back to CiscoStack method
 | 
						|
    else {
 | 
						|
        return $c6500->SUPER::i_duplex($partial);
 | 
						|
    }
 | 
						|
}
 | 
						|
 | 
						|
# Newer software uses portDuplex as admin setting
 | 
						|
 | 
						|
sub i_duplex_admin {
 | 
						|
    my $c6500 = shift;
 | 
						|
    my $partial = shift;
 | 
						|
 | 
						|
    my $el_duplex = $c6500->el_duplex($partial);
 | 
						|
 | 
						|
    # Newer software     
 | 
						|
    if (defined $el_duplex and scalar(keys %$el_duplex)){
 | 
						|
        my $p_port   = $c6500->p_port()   || {};
 | 
						|
        my $p_duplex = $c6500->p_duplex() || {};
 | 
						|
        
 | 
						|
        my $i_duplex_admin = {};
 | 
						|
        foreach my $port (keys %$p_duplex) {
 | 
						|
            my $iid = $p_port->{$port};
 | 
						|
            next unless defined $iid;
 | 
						|
            next if (defined $partial and $iid !~ /^$partial$/);
 | 
						|
            
 | 
						|
            $i_duplex_admin->{$iid} = $p_duplex->{$port};
 | 
						|
        }
 | 
						|
        return $i_duplex_admin;
 | 
						|
    }
 | 
						|
    # Fall back to CiscoStack method
 | 
						|
    else {
 | 
						|
        return $c6500->SUPER::i_duplex_admin($partial);
 | 
						|
    }    
 | 
						|
}
 | 
						|
 | 
						|
sub set_i_duplex_admin {
 | 
						|
    # map a textual duplex to an integer one the switch understands
 | 
						|
    my %duplexes = qw/half 1 full 2 auto 4/;
 | 
						|
 | 
						|
    my $c6500 = shift;
 | 
						|
    my ($duplex, $iid) = @_;
 | 
						|
 | 
						|
    my $el_duplex = $c6500->el_duplex($iid);
 | 
						|
 | 
						|
    # Auto duplex only supported on newer software
 | 
						|
    if (defined $el_duplex and scalar(keys %$el_duplex)){
 | 
						|
        my $p_port  = $c6500->p_port() || {};
 | 
						|
        my %reverse_p_port = reverse %$p_port;
 | 
						|
 | 
						|
       $duplex = lc($duplex);
 | 
						|
 | 
						|
       return 0 unless defined $duplexes{$duplex};
 | 
						|
 | 
						|
       $iid = $reverse_p_port{$iid};
 | 
						|
 | 
						|
       return $c6500->set_p_duplex($duplexes{$duplex}, $iid);
 | 
						|
    }
 | 
						|
    else {
 | 
						|
        $c6500->SUPER::set_i_duplex_admin;
 | 
						|
    }
 | 
						|
}
 | 
						|
 | 
						|
1;
 | 
						|
__END__
 | 
						|
 | 
						|
=head1 NAME
 | 
						|
 | 
						|
SNMP::Info::Layer3::C6500 - SNMP Interface to Cisco Catalyst 6500 Layer 2/3
 | 
						|
Switches running IOS and/or CatOS
 | 
						|
 | 
						|
=head1 AUTHOR
 | 
						|
 | 
						|
Max Baker
 | 
						|
 | 
						|
=head1 SYNOPSIS
 | 
						|
 | 
						|
 # Let SNMP::Info determine the correct subclass for you. 
 | 
						|
 my $c6500 = new SNMP::Info(
 | 
						|
                        AutoSpecify => 1,
 | 
						|
                        Debug       => 1,
 | 
						|
                        # These arguments are passed directly to SNMP::Session
 | 
						|
                        DestHost    => 'myswitch',
 | 
						|
                        Community   => 'public',
 | 
						|
                        Version     => 2
 | 
						|
                        ) 
 | 
						|
    or die "Can't connect to DestHost.\n";
 | 
						|
 | 
						|
 my $class      = $c6500->class();
 | 
						|
 print "SNMP::Info determined this device to fall under subclass : $class\n";
 | 
						|
 | 
						|
=head1 DESCRIPTION
 | 
						|
 | 
						|
Abstraction subclass for Cisco Catalyst 6500 Layer 2/3 Switches.  
 | 
						|
 | 
						|
These devices run IOS but have some of the same charactersitics as the Catalyst
 | 
						|
WS-C family (5xxx). For example, forwarding tables are held in VLANs, and
 | 
						|
extended interface information is gleened from CISCO-SWITCH-MIB.
 | 
						|
 | 
						|
For speed or debugging purposes you can call the subclass directly, but not
 | 
						|
after determining a more specific class using the method above. 
 | 
						|
 | 
						|
 my $c6500 = new SNMP::Info::Layer3::C6500(...);
 | 
						|
 | 
						|
=head2 Inherited Classes
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=item SNMP::Info::CiscoVTP
 | 
						|
 | 
						|
=item SNMP::Info::CiscoStack
 | 
						|
 | 
						|
=item SNMP::Info::CDP
 | 
						|
 | 
						|
=item SNMP::Info::CiscoStats
 | 
						|
 | 
						|
=item SNMP::Info::CiscoImage
 | 
						|
 | 
						|
=item SNMP::Info::CiscoPortSecurity
 | 
						|
 | 
						|
=item SNMP::Info::CiscoConfig
 | 
						|
 | 
						|
=item SNMP::Info::CiscoPower
 | 
						|
 | 
						|
=item SNMP::Info::Layer3
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head2 Required MIBs
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=item Inherited Classes' MIBs
 | 
						|
 | 
						|
See L<SNMP::Info::CiscoVTP/"Required MIBs"> for its own MIB requirements.
 | 
						|
 | 
						|
See L<SNMP::Info::CiscoStack/"Required MIBs"> for its own MIB requirements.
 | 
						|
 | 
						|
See L<SNMP::Info::CDP/"Required MIBs"> for its own MIB requirements.
 | 
						|
 | 
						|
See L<SNMP::Info::CiscoStats/"Required MIBs"> for its own MIB requirements.
 | 
						|
 | 
						|
See L<SNMP::Info::CiscoImage/"Required MIBs"> for its own MIB requirements.
 | 
						|
 | 
						|
See L<SNMP::Info::CiscoPortSecurity/"Required MIBs"> for its own MIB requirements.
 | 
						|
 | 
						|
See L<SNMP::Info::CiscoConfig/"Required MIBs"> for its own MIB requirements.
 | 
						|
 | 
						|
See L<SNMP::Info::CiscoPower/"Required MIBs"> for its own MIB requirements.
 | 
						|
 | 
						|
See L<SNMP::Info::Layer3/"Required MIBs"> for its own MIB requirements.
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head1 GLOBALS
 | 
						|
 | 
						|
These are methods that return scalar value from SNMP
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=item $c6500->vendor()
 | 
						|
 | 
						|
    Returns 'cisco'
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head2 Global Methods imported from SNMP::Info::CiscoVTP
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::CiscoVTP/"GLOBALS"> for details.
 | 
						|
 | 
						|
=head2 Global Methods imported from SNMP::Info::CiscoStack
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::CiscoStack/"GLOBALS"> for details.
 | 
						|
 | 
						|
=head2 Globals imported from SNMP::Info::CDP
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::CDP/"GLOBALS"> for details.
 | 
						|
 | 
						|
=head2 Globals imported from SNMP::Info::CiscoStats
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::CiscoStats/"GLOBALS"> for details.
 | 
						|
 | 
						|
=head2 Globals imported from SNMP::Info::CiscoImage
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::CiscoImage/"GLOBALS"> for details.
 | 
						|
 | 
						|
=head2 Globals imported from SNMP::Info::CiscoPortSecurity
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::CiscoPortSecurity/"GLOBALS"> for details.
 | 
						|
 | 
						|
=head2 Globals imported from SNMP::Info::CiscoConfig
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::CiscoConfig/"GLOBALS"> for details.
 | 
						|
 | 
						|
=head2 Globals imported from SNMP::Info::CiscoPower
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::CiscoPower/"GLOBALS"> for details.
 | 
						|
 | 
						|
=head2 Globals imported from SNMP::Info::Layer3
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::Layer3/"GLOBALS"> for details.
 | 
						|
 | 
						|
=head1 TABLE METHODS
 | 
						|
 | 
						|
These are methods that return tables of information in the form of a reference
 | 
						|
to a hash.
 | 
						|
 | 
						|
=head2 Overrides
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=item $c6500->i_duplex()
 | 
						|
 | 
						|
Returns reference to hash of iid to current link duplex setting.
 | 
						|
 | 
						|
Newer software versions return duplex based upon the result of
 | 
						|
$c6500->el_duplex().  Otherwise it uses the result of the call to
 | 
						|
CiscoStack i_duplex().
 | 
						|
 | 
						|
See L<SNMP::Info::Etherlike> for el_duplex() method and
 | 
						|
L<SNMP::Info::CiscoStack> for its i_duplex() method.
 | 
						|
 | 
						|
=item $c6500->i_duplex_admin()
 | 
						|
 | 
						|
Returns reference to hash of iid to administrative duplex setting.
 | 
						|
 | 
						|
Newer software versions return duplex based upon the result of
 | 
						|
$c6500->p_duplex().  Otherwise it uses the result of the call to
 | 
						|
CiscoStack i_duplex().
 | 
						|
 | 
						|
See L<SNMP::Info::CiscoStack> for its i_duplex() and p_duplex() methods.
 | 
						|
 | 
						|
=item $c6500->set_i_duplex_admin(duplex, ifIndex)
 | 
						|
 | 
						|
Sets port duplex, must be supplied with duplex and port ifIndex.
 | 
						|
 | 
						|
Speed choices are 'auto', 'half', 'full'.
 | 
						|
 | 
						|
Crosses $c6500->p_port() with $c6500->p_duplex() to utilize port ifIndex.
 | 
						|
 | 
						|
    Example:
 | 
						|
    my %if_map = reverse %{$c6500->interfaces()};
 | 
						|
    $c6500->set_i_duplex_admin('auto', $if_map{'FastEthernet0/1'}) 
 | 
						|
        or die "Couldn't change port duplex. ",$c6500->error(1);
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head2 Table Methods imported from SNMP::Info::CiscoVTP
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::CiscoVTP/"TABLE METHODS"> for details.
 | 
						|
 | 
						|
=head2 Table Methods imported from SNMP::Info::CiscoStack
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::CiscoStack/"TABLE METHODS"> for details.
 | 
						|
 | 
						|
=head2 Table Methods imported from SNMP::Info::CDP
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::CDP/"TABLE METHODS"> for details.
 | 
						|
 | 
						|
=head2 Table Methods imported from SNMP::Info::CiscoStats
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::CiscoStats/"TABLE METHODS"> for details.
 | 
						|
 | 
						|
=head2 Table Methods imported from SNMP::Info::CiscoImage
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::CiscoImage/"TABLE METHODS"> for details.
 | 
						|
 | 
						|
=head2 Table Methods imported from SNMP::Info::CiscoPortSecurity
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::CiscoPortSecurity/"TABLE METHODS"> for details.
 | 
						|
 | 
						|
=head2 Table Methods imported from SNMP::Info::CiscoConfig
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::CiscoConfig/"TABLE METHODS"> for details.
 | 
						|
 | 
						|
=head2 Table Methods imported from SNMP::Info::CiscoPower
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::CiscoPower/"TABLE METHODS"> for details.
 | 
						|
 | 
						|
=head2 Table Methods imported from SNMP::Info::Layer3
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::Layer3/"TABLE METHODS"> for details.
 | 
						|
 | 
						|
=cut
 | 
						|
 |