# SNMP::Info::Layer3::Dell - SNMP Interface to Dell devices
 | 
						|
#
 | 
						|
# Copyright (c) 2008 Eric Miller
 | 
						|
# All rights reserved.
 | 
						|
#
 | 
						|
# Redistribution and use in source and binary forms, with or without
 | 
						|
# modification, are permitted provided that the following conditions are met:
 | 
						|
#
 | 
						|
#     * Redistributions of source code must retain the above copyright notice,
 | 
						|
#       this list of conditions and the following disclaimer.
 | 
						|
#     * Redistributions in binary form must reproduce the above copyright
 | 
						|
#       notice, this list of conditions and the following disclaimer in the
 | 
						|
#       documentation and/or other materials provided with the distribution.
 | 
						|
#     * Neither the name of the University of California, Santa Cruz nor the
 | 
						|
#       names of its contributors may be used to endorse or promote products
 | 
						|
#       derived from this software without specific prior written permission.
 | 
						|
#
 | 
						|
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
 | 
						|
# AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
 | 
						|
# IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
 | 
						|
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE
 | 
						|
# LIABLE FOR # ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
 | 
						|
# CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
 | 
						|
# SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
 | 
						|
# INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
 | 
						|
# CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
 | 
						|
# ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
 | 
						|
# POSSIBILITY OF SUCH DAMAGE.
 | 
						|
 | 
						|
package SNMP::Info::Layer3::Dell;
 | 
						|
 | 
						|
use strict;
 | 
						|
use warnings;
 | 
						|
use Exporter;
 | 
						|
use SNMP::Info::Layer3;
 | 
						|
 | 
						|
@SNMP::Info::Layer3::Dell::ISA       = qw/SNMP::Info::Layer3 Exporter/;
 | 
						|
@SNMP::Info::Layer3::Dell::EXPORT_OK = qw//;
 | 
						|
 | 
						|
our ($VERSION, %GLOBALS, %FUNCS, %MIBS, %MUNGE);
 | 
						|
 | 
						|
$VERSION = '3.71';
 | 
						|
 | 
						|
%MIBS = (
 | 
						|
    %SNMP::Info::Layer3::MIBS,
 | 
						|
    'RADLAN-COPY-MIB'                => 'rlCopySourceLocation',
 | 
						|
    'RADLAN-Physicaldescription-MIB' => 'rlPhdStackReorder',
 | 
						|
    'RADLAN-rlInterfaces'            => 'rlIfNumOfLoopbackPorts',
 | 
						|
    'RADLAN-HWENVIROMENT'            => 'rlEnvPhysicalDescription',
 | 
						|
    'Dell-Vendor-MIB'                => 'productIdentificationVersion',
 | 
						|
    'DELL-REF-MIB'                   => 'dell6224Switch',
 | 
						|
);
 | 
						|
 | 
						|
%GLOBALS = (
 | 
						|
    %SNMP::Info::Layer3::GLOBALS,
 | 
						|
    'dell_os_ver'  => 'productIdentificationVersion',
 | 
						|
    'dell_id_name' => 'productIdentificationDisplayName',
 | 
						|
);
 | 
						|
 | 
						|
%FUNCS = (
 | 
						|
    %SNMP::Info::Layer3::FUNCS,
 | 
						|
 | 
						|
    # RADLAN-rlInterfaces:swIfTable
 | 
						|
    'dell_duplex_admin' => 'swIfDuplexAdminMode',
 | 
						|
    'dell_duplex'       => 'swIfDuplexOperMode',
 | 
						|
    'dell_tag_mode'     => 'swIfTaggedMode',
 | 
						|
    'dell_i_type'       => 'swIfType',
 | 
						|
    'dell_fc_admin'     => 'swIfFlowControlMode',
 | 
						|
    'dell_speed_admin'  => 'swIfSpeedAdminMode',
 | 
						|
    'dell_auto'         => 'swIfSpeedDuplexAutoNegotiation',
 | 
						|
    'dell_fc'           => 'swIfOperFlowControlMode',
 | 
						|
 | 
						|
    # RADLAN-Physicaldescription-MIB:rlPhdUnitGenParamTable
 | 
						|
    'dell_unit'      => 'rlPhdUnitGenParamStackUnit',
 | 
						|
    'dell_sw_ver'    => 'rlPhdUnitGenParamSoftwareVersion',
 | 
						|
    'dell_fw_ver'    => 'rlPhdUnitGenParamFirmwareVersion',
 | 
						|
    'dell_hw_ver'    => 'rlPhdUnitGenParamHardwareVersion',
 | 
						|
    'dell_serial_no' => 'rlPhdUnitGenParamSerialNum',
 | 
						|
    'dell_asset_no'  => 'rlPhdUnitGenParamAssetTag',
 | 
						|
 | 
						|
    # RADLAN-COPY-MIB:rlCopyTable
 | 
						|
    'dell_cp_idx'     => 'rlCopyIndex',
 | 
						|
    'dell_cp_sloc'    => 'rlCopySourceLocation',
 | 
						|
    'dell_cp_sip'     => 'rlCopySourceIpAddress',
 | 
						|
    'dell_cp_sunit'   => 'rlCopySourceUnitNumber',
 | 
						|
    'dell_cp_sfile'   => 'rlCopySourceFileName',
 | 
						|
    'dell_cp_stype'   => 'rlCopySourceFileType',
 | 
						|
    'dell_cp_dloc'    => 'rlCopyDestinationLocation',
 | 
						|
    'dell_cp_dip'     => 'rlCopyDestinationIpAddress',
 | 
						|
    'dell_cp_dunit'   => 'rlCopyDestinationUnitNumber',
 | 
						|
    'dell_cp_dfile'   => 'rlCopyDestinationFileName',
 | 
						|
    'dell_cp_dtype'   => 'rlCopyDestinationFileType',
 | 
						|
    'dell_cp_state'   => 'rlCopyOperationState',
 | 
						|
    'dell_cp_bkgnd'   => 'rlCopyInBackground',
 | 
						|
    'dell_cp_rstatus' => 'rlCopyRowStatus',
 | 
						|
 | 
						|
    # RADLAN-HWENVIROMENT:rlEnvMonSupplyStatusTable
 | 
						|
    'dell_pwr_src'   => 'rlEnvMonSupplySource',
 | 
						|
    'dell_pwr_state' => 'rlEnvMonSupplyState',
 | 
						|
    'dell_pwr_desc'  => 'rlEnvMonSupplyStatusDescr',
 | 
						|
 | 
						|
    # RADLAN-HWENVIROMENT:rlEnvMonFanStatusTable
 | 
						|
    'dell_fan_state' => 'rlEnvMonFanState',
 | 
						|
    'dell_fan_desc'  => 'rlEnvMonFanStatusDescr',
 | 
						|
);
 | 
						|
 | 
						|
%MUNGE = ( %SNMP::Info::Layer3::MUNGE, );
 | 
						|
 | 
						|
# Method OverRides
 | 
						|
 | 
						|
sub model {
 | 
						|
    my $dell = shift;
 | 
						|
 | 
						|
    my $name  = $dell->dell_id_name();
 | 
						|
    my $id    = $dell->id();
 | 
						|
 | 
						|
    if ( defined $name and $name =~ m/(\d+)/ ) {
 | 
						|
        return $1;
 | 
						|
    }
 | 
						|
 | 
						|
    return unless defined $id;
 | 
						|
 | 
						|
    my $model = SNMP::translateObj($id);
 | 
						|
 | 
						|
    if (defined $model) {
 | 
						|
        $model =~ s/^dell//;
 | 
						|
        $model =~ s/Switch$//;
 | 
						|
        return $model;
 | 
						|
    }
 | 
						|
    return $id;
 | 
						|
}
 | 
						|
 | 
						|
sub vendor {
 | 
						|
    my $dell = shift;
 | 
						|
 | 
						|
    return $dell->_vendor();
 | 
						|
}
 | 
						|
 | 
						|
sub os {
 | 
						|
    my $dell = shift;
 | 
						|
 | 
						|
    return $dell->_vendor();
 | 
						|
}
 | 
						|
 | 
						|
sub os_ver {
 | 
						|
    my $dell = shift;
 | 
						|
 | 
						|
    my $entity_os = $dell->entity_derived_os_ver();
 | 
						|
    if ( defined $entity_os and $entity_os !~ /^\s*$/ ){
 | 
						|
        return $entity_os;
 | 
						|
    }
 | 
						|
 | 
						|
    my $dell_os  = $dell->dell_os_ver();
 | 
						|
    if ( defined $dell_os and $dell_os !~ /^\s*$/ ) {
 | 
						|
        return $dell_os;
 | 
						|
    }
 | 
						|
    return;
 | 
						|
}
 | 
						|
 | 
						|
# check all fans, and report overall status
 | 
						|
sub fan {
 | 
						|
    my $dell = shift;
 | 
						|
 | 
						|
    my $fan   = $dell->dell_fan_desc()  || {};
 | 
						|
    my $state = $dell->dell_fan_state() || {};
 | 
						|
 | 
						|
    if (scalar keys %$fan) {
 | 
						|
        my @messages = ();
 | 
						|
 | 
						|
        foreach my $k (keys %$fan) {
 | 
						|
            next if $state->{$k} and $state->{$k} eq 'normal';
 | 
						|
            push @messages, "$fan->{$k}: $state->{$k}";
 | 
						|
        }
 | 
						|
 | 
						|
        push @messages, ((scalar keys %$fan). " fans OK")
 | 
						|
            if scalar @messages == 0;
 | 
						|
 | 
						|
        return (join ", ", @messages);
 | 
						|
        }
 | 
						|
    return;
 | 
						|
}
 | 
						|
 | 
						|
sub ps1_type {
 | 
						|
    my $dell = shift;
 | 
						|
 | 
						|
    my $src  = $dell->dell_pwr_src()  || {};
 | 
						|
 | 
						|
    foreach my $k (sort keys %$src) {
 | 
						|
        next unless $src->{$k};
 | 
						|
        return $src->{$k};
 | 
						|
    }
 | 
						|
    return;
 | 
						|
}
 | 
						|
 | 
						|
sub ps2_type {
 | 
						|
    my $dell = shift;
 | 
						|
 | 
						|
    my $src  = $dell->dell_pwr_src()  || {};
 | 
						|
 | 
						|
    my $i = 0;
 | 
						|
    foreach my $k (sort keys %$src) {
 | 
						|
        $i++;
 | 
						|
        next unless $src->{$k} and $i == 2;
 | 
						|
        return $src->{$k};
 | 
						|
    }
 | 
						|
    return;
 | 
						|
}
 | 
						|
 | 
						|
sub ps1_status {
 | 
						|
    my $dell = shift;
 | 
						|
 | 
						|
    my $status  = $dell->dell_pwr_state()  || {};
 | 
						|
 | 
						|
    foreach my $k (sort keys %$status) {
 | 
						|
        next unless $status->{$k};
 | 
						|
        return $status->{$k};
 | 
						|
    }
 | 
						|
    return;
 | 
						|
}
 | 
						|
 | 
						|
sub ps2_status {
 | 
						|
    my $dell = shift;
 | 
						|
 | 
						|
    my $status  = $dell->dell_pwr_state()  || {};
 | 
						|
 | 
						|
    my $i = 0;
 | 
						|
    foreach my $k (sort keys %$status) {
 | 
						|
        $i++;
 | 
						|
        next unless $status->{$k} and $i == 2;
 | 
						|
        return $status->{$k};
 | 
						|
    }
 | 
						|
    return;
 | 
						|
}
 | 
						|
 | 
						|
sub interfaces {
 | 
						|
    my $dell    = shift;
 | 
						|
    my $partial = shift;
 | 
						|
 | 
						|
    my $i_descr = $dell->i_description($partial) || {};
 | 
						|
    my $i_name  = $dell->orig_i_name($partial)   || {};
 | 
						|
 | 
						|
    # Descriptions are all the same on some Dells, so use name instead if
 | 
						|
    # available
 | 
						|
    foreach my $iid ( keys %$i_name ) {
 | 
						|
        my $name = $i_name->{$iid};
 | 
						|
        next unless defined $name;
 | 
						|
        $i_descr->{$iid} = $name;
 | 
						|
    }
 | 
						|
 | 
						|
    return $i_descr;
 | 
						|
}
 | 
						|
 | 
						|
sub i_duplex {
 | 
						|
    my $dell    = shift;
 | 
						|
    my $partial = shift;
 | 
						|
 | 
						|
    my $dell_duplex = $dell->dell_duplex($partial) || {};
 | 
						|
 | 
						|
    my %i_duplex;
 | 
						|
    foreach my $if ( keys %$dell_duplex ) {
 | 
						|
        my $duplex = $dell_duplex->{$if};
 | 
						|
        next unless defined $duplex;
 | 
						|
        next if $duplex eq 'unknown';
 | 
						|
 | 
						|
        $i_duplex{$if} = $duplex;
 | 
						|
    }
 | 
						|
    return \%i_duplex;
 | 
						|
}
 | 
						|
 | 
						|
sub i_duplex_admin {
 | 
						|
    my $dell    = shift;
 | 
						|
    my $partial = shift;
 | 
						|
 | 
						|
    my $interfaces  = $dell->interfaces($partial)        || {};
 | 
						|
    my $dell_duplex = $dell->dell_duplex_admin($partial) || {};
 | 
						|
    my $dell_auto   = $dell->dell_auto($partial)         || {};
 | 
						|
 | 
						|
    my %i_duplex_admin;
 | 
						|
    foreach my $if ( keys %$interfaces ) {
 | 
						|
        my $duplex = $dell_duplex->{$if};
 | 
						|
        next unless defined $duplex;
 | 
						|
        my $auto = $dell_auto->{$if} || 'disabled';
 | 
						|
 | 
						|
        $duplex = 'half' if ( $duplex eq 'half' and $auto eq 'disabled' );
 | 
						|
        $duplex = 'full' if ( $duplex eq 'full' and $auto eq 'disabled' );
 | 
						|
        $duplex = 'auto' if $auto eq 'enabled';
 | 
						|
        $i_duplex_admin{$if} = $duplex;
 | 
						|
    }
 | 
						|
    return \%i_duplex_admin;
 | 
						|
}
 | 
						|
 | 
						|
sub _vendor {
 | 
						|
    my $dell = shift;
 | 
						|
 | 
						|
    my $id = $dell->id() || 'undef';
 | 
						|
    my %oidmap = (
 | 
						|
        2    => 'ibm',
 | 
						|
        674  => 'dell',
 | 
						|
        3955 => 'linksys',
 | 
						|
    );
 | 
						|
    $id = $1 if ( defined($id) && $id =~ /^\.1\.3\.6\.1\.4\.1\.(\d+)/ );
 | 
						|
 | 
						|
    if ( defined($id) and exists( $oidmap{$id} ) ) {
 | 
						|
        return $oidmap{$id};
 | 
						|
    }
 | 
						|
    else {
 | 
						|
        return $id;
 | 
						|
    }
 | 
						|
}
 | 
						|
 | 
						|
# dot1qTpFdbTable uses dot1qVlanIndex rather than dot1qFdbId as index,
 | 
						|
# so pretend we don't have the mapping
 | 
						|
sub qb_fdb_index {return}
 | 
						|
 | 
						|
1;
 | 
						|
__END__
 | 
						|
 | 
						|
=head1 NAME
 | 
						|
 | 
						|
SNMP::Info::Layer3::Dell - SNMP Interface to Dell Power Connect Network
 | 
						|
Devices
 | 
						|
 | 
						|
=head1 AUTHOR
 | 
						|
 | 
						|
Eric Miller
 | 
						|
 | 
						|
=head1 SYNOPSIS
 | 
						|
 | 
						|
 # Let SNMP::Info determine the correct subclass for you.
 | 
						|
 my $dell = new SNMP::Info(
 | 
						|
                          AutoSpecify => 1,
 | 
						|
                          Debug       => 1,
 | 
						|
                          DestHost    => 'myswitch',
 | 
						|
                          Community   => 'public',
 | 
						|
                          Version     => 2
 | 
						|
                        )
 | 
						|
    or die "Can't connect to DestHost.\n";
 | 
						|
 | 
						|
 my $class = $dell->class();
 | 
						|
 | 
						|
 print "SNMP::Info determined this device to fall under subclass : $class\n";
 | 
						|
 | 
						|
=head1 DESCRIPTION
 | 
						|
 | 
						|
Provides abstraction to the configuration information obtainable from an
 | 
						|
Dell Power Connect device through SNMP.  D-Link and the IBM BladeCenter
 | 
						|
Gigabit Ethernet Switch Module also use this module based upon MIB support.
 | 
						|
 | 
						|
For speed or debugging purposes you can call the subclass directly, but not
 | 
						|
after determining a more specific class using the method above.
 | 
						|
 | 
						|
my $dell = new SNMP::Info::Layer3::Dell(...);
 | 
						|
 | 
						|
=head2 Inherited Classes
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=item SNMP::Info::Layer3
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head2 Required MIBs
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=item F<DELL-REF-MIB>
 | 
						|
 | 
						|
=item F<Dell-Vendor-MIB>
 | 
						|
 | 
						|
=item F<RADLAN-COPY-MIB>
 | 
						|
 | 
						|
=item F<RADLAN-HWENVIROMENT>
 | 
						|
 | 
						|
=item F<RADLAN-Physicaldescription-MIB>
 | 
						|
 | 
						|
=item F<RADLAN-rlInterfaces>
 | 
						|
 | 
						|
=item Inherited Classes' MIBs
 | 
						|
 | 
						|
See classes listed above for their required MIBs.
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head1 GLOBALS
 | 
						|
 | 
						|
These are methods that return scalar value from SNMP
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=item $dell->os_ver()
 | 
						|
 | 
						|
(C<productIdentificationVersion>)
 | 
						|
 | 
						|
=item $dell->dell_id_name()
 | 
						|
 | 
						|
(C<productIdentificationDisplayName>)
 | 
						|
 | 
						|
=item $dell->model()
 | 
						|
 | 
						|
Returns model type.  Returns numeric from
 | 
						|
(C<productIdentificationDisplayName>) if available, otherwise if returns
 | 
						|
description().
 | 
						|
 | 
						|
=item $dell->vendor()
 | 
						|
 | 
						|
Returns 'dell', 'dlink', or 'ibm' based upon the IANA enterprise number in
 | 
						|
id().  Defaults to 'dlink'.
 | 
						|
 | 
						|
=item $dell->os()
 | 
						|
 | 
						|
Returns 'dell', 'dlink', or 'ibm' based upon the IANA enterprise number in
 | 
						|
id().  Defaults to 'dlink'.
 | 
						|
 | 
						|
=item $dell->fan()
 | 
						|
 | 
						|
Return the status of all fans from the F<Dell-Vendor-MIB>
 | 
						|
 | 
						|
=item $dell->ps1_type()
 | 
						|
 | 
						|
Return the type of the first power supply from the F<Dell-Vendor-MIB>
 | 
						|
 | 
						|
=item $dell->ps2_type()
 | 
						|
 | 
						|
Return the type of the second power supply from the F<Dell-Vendor-MIB>
 | 
						|
 | 
						|
=item $dell->ps1_status()
 | 
						|
 | 
						|
Return the status of the first power supply from the F<Dell-Vendor-MIB>
 | 
						|
 | 
						|
=item $dell->ps2_status()
 | 
						|
 | 
						|
Return the status of the second power supply from the F<Dell-Vendor-MIB>
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head2 Overrides
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=item $dell->serial()
 | 
						|
 | 
						|
Returns serial number. Returns (C<rlPhdUnitGenParamSerialNum>) if available,
 | 
						|
otherwise uses the Layer3 serial method.
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head2 Globals imported from SNMP::Info::Layer3
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::Layer3/"GLOBALS"> for details.
 | 
						|
 | 
						|
=head1 TABLE METHODS
 | 
						|
 | 
						|
These are methods that return tables of information in the form of a reference
 | 
						|
to a hash.
 | 
						|
 | 
						|
=head2 RADLAN Interface Table (C<swIfTable>)
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=item $dell->dell_duplex_admin()
 | 
						|
 | 
						|
(C<swIfDuplexAdminMode>)
 | 
						|
 | 
						|
=item $dell->dell_duplex()
 | 
						|
 | 
						|
(C<swIfDuplexOperMode>)
 | 
						|
 | 
						|
=item $dell->dell_tag_mode()
 | 
						|
 | 
						|
(C<swIfTaggedMode>)
 | 
						|
 | 
						|
=item $dell->dell_i_type()
 | 
						|
 | 
						|
(C<swIfType>)
 | 
						|
 | 
						|
=item $dell->dell_fc_admin()
 | 
						|
 | 
						|
(C<swIfFlowControlMode>)
 | 
						|
 | 
						|
=item $dell->dell_speed_admin()
 | 
						|
 | 
						|
(C<swIfSpeedAdminMode>)
 | 
						|
 | 
						|
=item $dell->dell_auto()
 | 
						|
 | 
						|
(C<swIfSpeedDuplexAutoNegotiation>)
 | 
						|
 | 
						|
=item $dell->dell_fc()
 | 
						|
 | 
						|
(C<swIfOperFlowControlMode>)
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head2 Overrides
 | 
						|
 | 
						|
=over
 | 
						|
 | 
						|
=item $dell->interfaces()
 | 
						|
 | 
						|
Returns the map between SNMP Interface Identifier (iid) and physical port
 | 
						|
name.  Uses name if available instead of description since descriptions are
 | 
						|
sometimes not unique.
 | 
						|
 | 
						|
=item $dell->i_duplex()
 | 
						|
 | 
						|
Returns reference to map of IIDs to current link duplex.
 | 
						|
 | 
						|
=item $dell->i_duplex_admin()
 | 
						|
 | 
						|
Returns reference to hash of iid to current link administrative duplex
 | 
						|
setting.
 | 
						|
 | 
						|
=item $dell->qb_fdb_index()
 | 
						|
 | 
						|
Returns nothing to work around incorrect indexing of C<dot1qTpFdbTable>
 | 
						|
 | 
						|
=back
 | 
						|
 | 
						|
=head2 Table Methods imported from SNMP::Info::Layer3
 | 
						|
 | 
						|
See documentation in L<SNMP::Info::Layer3/"TABLE METHODS"> for details.
 | 
						|
 | 
						|
=cut
 |