# SNMP::Info::Layer3::Contivity
|
|
# $Id$
|
|
#
|
|
# Copyright (c) 2010 Eric Miller
|
|
# All rights reserved.
|
|
#
|
|
# Redistribution and use in source and binary forms, with or without
|
|
# modification, are permitted provided that the following conditions are met:
|
|
#
|
|
# * Redistributions of source code must retain the above copyright notice,
|
|
# this list of conditions and the following disclaimer.
|
|
# * Redistributions in binary form must reproduce the above copyright
|
|
# notice, this list of conditions and the following disclaimer in the
|
|
# documentation and/or other materials provided with the distribution.
|
|
# * Neither the name of the University of California, Santa Cruz nor the
|
|
# names of its contributors may be used to endorse or promote products
|
|
# derived from this software without specific prior written permission.
|
|
#
|
|
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
|
|
# AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
|
# IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
|
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE
|
|
# LIABLE FOR # ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
|
|
# CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
|
|
# SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
|
|
# INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
|
|
# CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
|
|
# ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
|
|
# POSSIBILITY OF SUCH DAMAGE.
|
|
|
|
package SNMP::Info::Layer3::Contivity;
|
|
|
|
use strict;
|
|
use Exporter;
|
|
use SNMP::Info;
|
|
use SNMP::Info::Layer3;
|
|
use SNMP::Info::Entity;
|
|
|
|
@SNMP::Info::Layer3::Contivity::ISA
|
|
= qw/SNMP::Info SNMP::Info::Layer3 SNMP::Info::Entity Exporter/;
|
|
@SNMP::Info::Layer3::Contivity::EXPORT_OK = qw//;
|
|
|
|
use vars qw/$VERSION %GLOBALS %FUNCS %MIBS %MUNGE/;
|
|
|
|
$VERSION = '3.18';
|
|
|
|
%MIBS = (
|
|
%SNMP::Info::MIBS, %SNMP::Info::Layer3::MIBS, %SNMP::Info::Entity::MIBS,
|
|
);
|
|
|
|
%GLOBALS = (
|
|
%SNMP::Info::GLOBALS, %SNMP::Info::Layer3::GLOBALS,
|
|
%SNMP::Info::Entity::GLOBALS,
|
|
);
|
|
|
|
%FUNCS = (
|
|
%SNMP::Info::FUNCS, %SNMP::Info::Layer3::FUNCS,
|
|
%SNMP::Info::Entity::FUNCS,
|
|
);
|
|
|
|
%MUNGE = (
|
|
%SNMP::Info::MUNGE, %SNMP::Info::Layer3::MUNGE,
|
|
%SNMP::Info::Entity::MUNGE,
|
|
);
|
|
|
|
sub layers {
|
|
return '00000100';
|
|
}
|
|
|
|
sub vendor {
|
|
return 'avaya';
|
|
}
|
|
|
|
sub model {
|
|
my $contivity = shift;
|
|
my $e_model = $contivity->e_model() || {};
|
|
|
|
my $model = $e_model->{1} || undef;
|
|
|
|
return $1 if ( defined $model and $model =~ /(CES\d+|NVR\d+)/i );
|
|
return;
|
|
}
|
|
|
|
sub os {
|
|
return 'contivity';
|
|
}
|
|
|
|
sub os_ver {
|
|
my $contivity = shift;
|
|
my $descr = $contivity->description();
|
|
return unless defined $descr;
|
|
|
|
if ( $descr =~ m/V(\d+_\d+\.\d+)/i ) {
|
|
return $1;
|
|
}
|
|
return;
|
|
}
|
|
|
|
sub mac {
|
|
my $contivity = shift;
|
|
my $i_mac = $contivity->i_mac();
|
|
|
|
# Return Interface MAC
|
|
foreach my $entry ( keys %$i_mac ) {
|
|
my $sn = $i_mac->{$entry};
|
|
next unless $sn;
|
|
return $sn;
|
|
}
|
|
return;
|
|
}
|
|
|
|
sub serial {
|
|
my $contivity = shift;
|
|
my $e_serial = $contivity->e_serial() || {};
|
|
|
|
my $serial = $e_serial->{1} || undef;
|
|
|
|
return $1 if ( defined $serial and $serial =~ /(\d+)/ );
|
|
return;
|
|
}
|
|
|
|
sub interfaces {
|
|
my $contivity = shift;
|
|
my $partial = shift;
|
|
|
|
my $description = $contivity->i_description($partial) || {};
|
|
|
|
my %interfaces = ();
|
|
foreach my $iid ( keys %$description ) {
|
|
my $desc = $description->{$iid};
|
|
|
|
# Skip everything except Ethernet interfaces
|
|
next unless ( defined $desc and $desc =~ /fe/i );
|
|
|
|
$interfaces{$iid} = $desc;
|
|
}
|
|
return \%interfaces;
|
|
}
|
|
|
|
sub i_name {
|
|
my $contivity = shift;
|
|
my $partial = shift;
|
|
|
|
my $i_name2 = $contivity->orig_i_name($partial) || {};
|
|
|
|
my %i_name;
|
|
foreach my $iid ( keys %$i_name2 ) {
|
|
my $name = $i_name2->{$iid};
|
|
|
|
#Skip everything except Ethernet interfaces
|
|
next unless ( defined $name and $name =~ /fe/i );
|
|
|
|
$name = $1 if $name =~ /(fei\.\d+\.\d+)/;
|
|
|
|
$i_name{$iid} = $name;
|
|
}
|
|
return \%i_name;
|
|
}
|
|
|
|
1;
|
|
__END__
|
|
|
|
=head1 NAME
|
|
|
|
SNMP::Info::Layer3::Contivity - SNMP Interface to Avaya/Nortel VPN Routers
|
|
(formerly Contivity Extranet Switches).
|
|
|
|
=head1 AUTHOR
|
|
|
|
Eric Miller
|
|
|
|
=head1 SYNOPSIS
|
|
|
|
# Let SNMP::Info determine the correct subclass for you.
|
|
my $contivity = new SNMP::Info(
|
|
AutoSpecify => 1,
|
|
Debug => 1,
|
|
DestHost => 'myswitch',
|
|
Community => 'public',
|
|
Version => 2
|
|
)
|
|
or die "Can't connect to DestHost.\n";
|
|
|
|
my $class = $contivity->class();
|
|
print "SNMP::Info determined this device to fall under subclass : $class\n";
|
|
|
|
=head1 DESCRIPTION
|
|
|
|
Abstraction subclass for Avaya/Nortel VPN Routers (formerly Contivity
|
|
Extranet Switch).
|
|
|
|
For speed or debugging purposes you can call the subclass directly, but not
|
|
after determining a more specific class using the method above.
|
|
|
|
my $contivity = new SNMP::Info::Layer3::Contivity(...);
|
|
|
|
=head2 Inherited Classes
|
|
|
|
=over
|
|
|
|
=item SNMP::Info
|
|
|
|
=item SNMP::Info::Layer3
|
|
|
|
=item SNMP::Info::Entity
|
|
|
|
=back
|
|
|
|
=head2 Required MIBs
|
|
|
|
=over
|
|
|
|
=item Inherited Classes' MIBs
|
|
|
|
See L<SNMP::Info/"Required MIBs"> for its own MIB requirements.
|
|
|
|
See L<SNMP::Info::Layer3/"Required MIBs"> for its own MIB requirements.
|
|
|
|
See L<SNMP::Info::Entity/"Required MIBs"> for its own MIB requirements.
|
|
|
|
=back
|
|
|
|
=head1 GLOBALS
|
|
|
|
These are methods that return scalar value from SNMP
|
|
|
|
=over
|
|
|
|
=item $contivity->vendor()
|
|
|
|
Returns 'avaya'
|
|
|
|
=item $contivity->model()
|
|
|
|
Returns the chassis name.
|
|
|
|
(C<entPhysicalModelName.1>)
|
|
|
|
=item $contivity->os()
|
|
|
|
Returns C<'CES'>
|
|
|
|
=item $contivity->os_ver()
|
|
|
|
Returns the software version extracted from (C<sysDescr>).
|
|
|
|
=item $contivity->serial()
|
|
|
|
Returns the chassis serial number.
|
|
|
|
(C<entPhysicalSerialNum.1>)
|
|
|
|
=item $contivity->mac()
|
|
|
|
Returns the MAC address of the first Ethernet Interface.
|
|
|
|
=back
|
|
|
|
=head2 Overrides
|
|
|
|
=over
|
|
|
|
=item $contivity->layers()
|
|
|
|
Returns 00000100. Contivity does not support bridge MIB, so override reported
|
|
layers.
|
|
|
|
=back
|
|
|
|
=head2 Globals imported from SNMP::Info
|
|
|
|
See documentation in L<SNMP::Info/"GLOBALS"> for details.
|
|
|
|
=head2 Globals imported from SNMP::Info::Layer3
|
|
|
|
See documentation in L<SNMP::Info::Layer3/"GLOBALS"> for details.
|
|
|
|
=head2 Globals imported from SNMP::Info::Entity
|
|
|
|
See documentation in L<SNMP::Info::Entity/"GLOBALS"> for details.
|
|
|
|
=head1 TABLE METHODS
|
|
|
|
These are methods that return tables of information in the form of a reference
|
|
to a hash.
|
|
|
|
=head2 Overrides
|
|
|
|
=over
|
|
|
|
=item $contivity->interfaces()
|
|
|
|
Returns reference to the map between IID and physical Port. Skips loopback
|
|
and tunnel interfaces.
|
|
|
|
=item $contivity->i_name()
|
|
|
|
Interface Name field. Skips loopback and tunnel interfaces.
|
|
|
|
=back
|
|
|
|
=head2 Table Methods imported from SNMP::Info
|
|
|
|
See documentation in L<SNMP::Info/"TABLE METHODS"> for details.
|
|
|
|
=head2 Table Methods imported from SNMP::Info::Layer3
|
|
|
|
See documentation in L<SNMP::Info::Layer3/"TABLE METHODS"> for details.
|
|
|
|
=head2 Table Methods imported from SNMP::Info::Entity
|
|
|
|
See documentation in L<SNMP::Info::Entity/"TABLE METHODS"> for details.
|
|
|
|
=cut
|