Files
snmp-info/Info/Layer2/C1900.pm
Eric Miller d9c87bdfbd - Modify inheritance to use Cisco classes before generic classes
- [ 1670428 ] add CiscoConfig inheritance
- Remove globs which shouldn't be needed with new inheritance chain
- Add CiscoPortSecurity inheritance so we can remove port security from CiscoStack
- POD updates
2007-04-15 02:44:14 +00:00

488 lines
12 KiB
Perl

# SNMP::Info::Layer2::C1900
# Max Baker
#
# Copyright (c) 2004 Max Baker changes from version 0.8 and beyond.
#
# Copyright (c) 2002,2003 Regents of the University of California
# All rights reserved.
#
# Redistribution and use in source and binary forms, with or without
# modification, are permitted provided that the following conditions are met:
#
# * Redistributions of source code must retain the above copyright notice,
# this list of conditions and the following disclaimer.
# * Redistributions in binary form must reproduce the above copyright notice,
# this list of conditions and the following disclaimer in the documentation
# and/or other materials provided with the distribution.
# * Neither the name of the University of California, Santa Cruz nor the
# names of its contributors may be used to endorse or promote products
# derived from this software without specific prior written permission.
#
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND
# ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
# WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
# DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR
# ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
# (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
# LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON
# ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
# (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS
# SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
package SNMP::Info::Layer2::C1900;
$VERSION = '1.05';
# $Id$
use strict;
use Exporter;
use SNMP::Info::CiscoVTP;
use SNMP::Info::CDP;
use SNMP::Info::CiscoStats;
use SNMP::Info::CiscoConfig;
use SNMP::Info::Layer2;
@SNMP::Info::Layer2::C1900::ISA = qw/SNMP::Info::CiscoVTP SNMP::Info::CDP
SNMP::Info::CiscoStats SNMP::Info::CiscoConfig SNMP::Info::Layer2 Exporter/;
@SNMP::Info::Layer2::C1900::EXPORT_OK = qw//;
use vars qw/$VERSION %FUNCS %GLOBALS %MIBS %MUNGE $AUTOLOAD $INIT $DEBUG/;
%GLOBALS = (
%SNMP::Info::Layer2::GLOBALS,
%SNMP::Info::CiscoConfig::GLOBALS,
%SNMP::Info::CiscoStats::GLOBALS,
%SNMP::Info::CDP::GLOBALS,
%SNMP::Info::CiscoVTP::GLOBALS,
'c1900_flash_status' => 'upgradeFlashBankStatus',
);
%FUNCS = (
%SNMP::Info::Layer2::FUNCS,
%SNMP::Info::CiscoConfig::FUNCS,
%SNMP::Info::CiscoStats::FUNCS,
%SNMP::Info::CDP::FUNCS,
%SNMP::Info::CiscoVTP::FUNCS,
# ESSWITCH-MIB
'c1900_p_index' => 'swPortIndex',
'c1900_p_ifindex' => 'swPortIfIndex',
'c1900_p_duplex' => 'swPortDuplexStatus',
'c1900_p_duplex_admin' => 'swPortFullDuplex',
'c1900_p_name' => 'swPortName',
'c1900_p_up_admin' => 'swPortAdminStatus',
'c1900_p_type' => 'swPortMediaCapability',
'c1900_p_media' => 'swPortConnectorType',
);
%MIBS = (
%SNMP::Info::Layer2::MIBS,
%SNMP::Info::CiscoConfig::MIBS,
%SNMP::Info::CiscoStats::MIBS,
%SNMP::Info::CDP::MIBS,
%SNMP::Info::CiscoVTP::MIBS,
# Also known as the ESSWITCH-MIB
'STAND-ALONE-ETHERNET-SWITCH-MIB' => 'series2000'
);
%MUNGE = (
%SNMP::Info::Layer2::MUNGE,
%SNMP::Info::CiscoConfig::MUNGE,
%SNMP::Info::CiscoStats::MUNGE,
%SNMP::Info::CDP::MUNGE,
%SNMP::Info::CiscoVTP::MUNGE,
);
sub bulkwalk_no { 1; }
sub cisco_comm_indexing { 1; }
sub vendor {
return 'cisco';
}
sub os {
return 'catalyst';
}
sub os_ver {
my $c1900 = shift;
# Check for superclass one
my $os_ver = $c1900->SUPER::os_ver();
return $os_ver if defined $os_ver;
my $c1900_flash_status = $c1900->c1900_flash_status();
return undef unless defined $c1900_flash_status;
if ( $c1900_flash_status =~ m/V(\d+\.\d+(\.\d+)?)/ ) {
return $1;
}
return undef;
}
sub interfaces {
my $c1900 = shift;
my $partial = shift;
my $i_descr = $c1900->i_description($partial) || {};
foreach my $iid ( keys %$i_descr ) {
$i_descr->{$iid} =~ s/\s*$//;
}
return $i_descr;
}
sub i_duplex {
my $c1900 = shift;
my $partial = shift;
my $c1900_p_duplex = $c1900->c1900_p_duplex($partial) || {};
my %i_duplex;
foreach my $if ( keys %$c1900_p_duplex ) {
my $duplex = $c1900_p_duplex->{$if};
next unless defined $duplex;
$duplex = 'half' if $duplex =~ /half/i;
$duplex = 'full' if $duplex =~ /full/i;
$i_duplex{$if} = $duplex;
}
return \%i_duplex;
}
sub i_duplex_admin {
my $c1900 = shift;
my $partial = shift;
my $c1900_p_admin = $c1900->c1900_p_duplex_admin($partial) || {};
my %i_duplex_admin;
foreach my $if ( keys %$c1900_p_admin ) {
my $duplex = $c1900_p_admin->{$if};
next unless defined $duplex;
$duplex = 'half' if $duplex =~ /disabled/i;
$duplex = 'full' if $duplex =~ /flow control/i;
$duplex = 'full' if $duplex =~ /enabled/i;
$duplex = 'auto' if $duplex =~ /auto/i;
$i_duplex_admin{$if} = $duplex;
}
return \%i_duplex_admin;
}
sub i_type {
my $c1900 = shift;
my $partial = shift;
my $i_type = $c1900->orig_i_type($partial) || {};
my $c1900_p_index = $c1900->c1900_p_index($partial) || {};
my $c1900_p_type = $c1900->c1900_p_type($partial) || {};
my $c1900_p_media = $c1900->c1900_p_media($partial) || {};
foreach my $p_iid ( keys %$c1900_p_index ) {
my $port = $c1900_p_index->{$p_iid};
next if ( defined $partial and $port !~ /^$partial$/ );
my $type = $c1900_p_type->{$p_iid};
my $media = $c1900_p_media->{$p_iid};
next unless defined $port;
next unless defined $type;
next unless defined $media;
$i_type->{$port} = "$type $media";
}
return $i_type;
}
sub i_name {
my $c1900 = shift;
my $partial = shift;
my $i_name = $c1900->orig_i_name($partial) || {};
my $c1900_p_name = $c1900->c1900_p_name($partial) || {};
foreach my $port ( keys %$c1900_p_name ) {
my $name = $c1900_p_name->{$port};
next unless defined $name;
next unless $name !~ /^\s*$/;
$i_name->{$port} = $name;
}
return $i_name;
}
sub set_i_duplex_admin {
my $c1900 = shift;
my ( $duplex, $port ) = @_;
# map a textual duplex to an integer one the switch understands
my %duplexes = qw/full 1 half 2 auto 3/;
my $iid = $c1900->c1900_p_ifindex($port);
$duplex = lc($duplex);
return 0 unless defined $duplexes{$duplex};
return $c1900->set_c1900_p_duplex_admin( $duplexes{$duplex}, $iid );
}
1;
__END__
=head1 NAME
SNMP::Info::Layer2::C1900 - SNMP Interface to data from Cisco Catlyst 1900
Network Switches running CatOS
=head1 AUTHOR
Max Baker
=head1 SYNOPSIS
# Let SNMP::Info determine the correct subclass for you.
my $c1900 = new SNMP::Info(
AutoSpecify => 1,
Debug => 1,
# These arguments are passed directly on to SNMP::Session
DestHost => 'myswitch',
Community => 'public',
Version => 1
)
or die "Can't connect to DestHost.\n";
my $class = $c1900->class();
print "SNMP::Info determined this device to fall under subclass : $class\n";
=head1 DESCRIPTION
Provides abstraction to the configuration information obtainable from a
Catalyst 1900 device through SNMP. See SNMP::Info for full documentation
Note that most of these devices only talk SNMP version 1, but not all.
For speed or debugging purposes you can call the subclass directly, but not
after determining a more specific class using the method above.
my $c1900 = new SNMP::Info::Layer2::C1900(...);
=head2 Inherited classes
=over
=item SNMP::Info::CiscoVTP
=item SNMP::Info::CDP
=item SNMP::Info::CiscoStats
=item SNMP::Info::CiscoConfig
=item SNMP::Info::Layer2
=back
=head2 Required MIBs
=over
=item STAND-ALONE-ETHERNET-SWITCH-MIB (ESSWITCH-MIB)
ESSWITCH-MIB is included in the Version 1 MIBS from Cisco.
They can be found at ftp://ftp.cisco.com/pub/mibs/v1/v1.tar.gz
=back
=head2 Inherited MIBs
See L<SNMP::Info::CiscoVTP/"Required MIBs"> for its MIB requirements.
See L<SNMP::Info::CDP/"Required MIBs"> for its MIB requirements.
See L<SNMP::Info::CiscoStats/"Required MIBs"> for its MIB requirements.
See L<SNMP::Info::CiscoConfig/"Required MIBs"> for its MIB requirements.
See L<SNMP::Info::Layer2/"Required MIBs"> for its MIB requirements.
=head1 GLOBALS
These are methods that return scalar value from SNMP
=over
=item $c1900->c1900_flash_status()
Usually contains the version of the software loaded in flash.
Used by os_ver()
B<STAND-ALONE-ETHERNET-SWITCH-MIB::upgradeFlashBankStatus>
=item $c1900->os()
Returns 'catalyst'
=item $c1900->os_ver()
Returns CatOS version if obtainable. First tries to use
SNMP::Info::CiscoStats->os_ver() . If that fails then it
checks for the presence of $c1900->c1900_flash_status() and culls
the version from there.
=item $c1900->vendor()
Returns 'cisco' :)
=back
=head2 Overrides
=over
=item $c1900->bulkwalk_no
Return C<1>. Bulkwalk is turned off for this class.
=back
=head2 Globals imported from SNMP::Info::CiscoVTP
See L<SNMP::Info::CiscoVTP/"GLOBALS"> for details.
=head2 Globals imported from SNMP::Info::CDP
See L<SNMP::Info::CDP/"GLOBALS"> for details.
=head2 Globals imported from SNMP::Info::CiscoStats
See L<SNMP::Info::CiscoStats/"GLOBALS"> for details.
=head2 Globals imported from SNMP::Info::CiscoConfig
See L<SNMP::Info::CiscoConfig/"GLOBALS"> for details.
=head2 Globals imported from SNMP::Info::Layer2
See L<SNMP::Info::Layer2/"GLOBALS"> for details.
=head1 TABLE METHODS
These are methods that return tables of information in the form of a reference
to a hash.
=head2 Overrides
=over
=item $c1900->i_duplex()
Returns reference to map of IIDs to current link duplex
=item $c1900->i_duplex_admin()
Returns reference to hash of IIDs to admin duplex setting
=item $c1900->i_name()
Crosses ifName with $c1900->c1900_p_name() and returns the human set port name
if exists.
=item $c1900->i_type()
Returns reference to hash of IID to port type
Takes the default ifType and overrides it with $c1900->c1900_p_type() and
$c1900->c1900_p_media() if they exist.
=back
=head2 STAND-ALONE-ETHERNET-SWITCH-MIB Switch Port Table Entries:
=over
=item $c1900->c1900_p_index()
Maps the Switch Port Table to the IID
B<swPortIfIndex>
=item $c1900->c1900_p_duplex()
Gives Port Duplex Info
(B<swPortDuplexStatus>)
=item $c1900->c1900_p_duplex_admin()
Gives admin setting for Duplex Info
(B<swPortFullDuplex>)
=item $c1900->c1900_p_name()
Gives human set name for port
(B<swPortName>)
=item $c1900->c1900_p_up_admin()
Gives Admin status of port enabled.
(B<swPortAdminStatus>)
=item $c1900->c1900_p_type()
Gives Type of port, ie. "general-ethernet"
(B<swPortMediaCapability>)
=item $c1900->c1900_p_media()
Gives the media of the port , ie "fiber-sc"
(B<swPortConnectorType>)
=back
=head2 Table Methods imported from SNMP::Info::CiscoVTP
See L<SNMP::Info::CiscoVTP/"TABLE METHODS"> for details.
=head2 Table Methods imported from SNMP::Info::CDP
See L<SNMP::Info::CDP/"TABLE METHODS"> for details.
=head2 Table Methods imported from SNMP::Info::CiscoStats
See L<SNMP::Info::CiscoStats/"TABLE METHODS"> for details.
=head2 Table Methods imported from SNMP::Info::CiscoConfig
See L<SNMP::Info::CiscoConfig/"TABLE METHODS"> for details.
=head2 Table Methods imported from SNMP::Info::Layer2
See L<SNMP::Info::Layer2/"TABLE METHODS"> for details.
=head1 SET METHODS
These are methods that provide SNMP set functionality for overridden methods or
provide a simpler interface to complex set operations. See
L<SNMP::Info/"SETTING DATA VIA SNMP"> for general information on set operations.
=over
=item $c1900->set_i_duplex_admin(duplex, ifIndex)
Sets port duplex, must be supplied with duplex and port ifIndex. Speed choices
are 'auto', 'half', 'full'.
Example:
my %if_map = reverse %{$c1900->interfaces()};
$c1900->set_i_duplex_admin('auto', $if_map{'1'})
or die "Couldn't change port duplex. ",$c1900->error(1);
=cut